WX<br />

<strong>DryLin</strong> ®<br />

<strong>DryLin</strong> ® – Lifetime Calculation<br />

✂<br />

<strong>DryLin</strong> ® Analysis<br />

<strong>DryLin</strong> ®<br />

<strong>DryLin</strong> ® Analysis<br />

Phone +49- (0) 22 03-96 49-145<br />

Fax +49- (0) 22 03-96 49-334<br />

The <strong>DryLin</strong> ® Expert System<br />

The <strong>DryLin</strong> Expert System enables the user to determine the suitability<br />

of <strong>DryLin</strong> ® <strong>linear</strong> <strong>guides</strong> for a particular application. In addition to the<br />

selection of different <strong>DryLin</strong> ® <strong>linear</strong> bearings, systems with one bearing<br />

on one shaft or rail can be calculated, as well as systems with two<br />

bearings on one or two shafts or rails. The installation position can be<br />

horizontal, lateral, or vertical.<br />

The following input data is also necessary: The coordinates of the<br />

center of gravity on the basis of a given coordinate system as well as<br />

the position of the drive and the desired distance to calculate the wear<br />

ratio. The Expert System then uses the input data to calculate:<br />

the wear of the bearings,<br />

the required drive force,<br />

the maximum permissible speed in constant use, and<br />

the theoretical clearance for a given center of gravity.<br />

Furthermore, a warning signal is emitted if there is a danger of deadlock,<br />

if the wear limit has been reached, the device is overloaded, or the<br />

movement is not expected to be smooth.<br />

The Expert System needs further calculations to take the following<br />

marginal conditions into account: dirty environments, acceleration<br />

forces, torque (crank drives, crank control systems, etc.) or transmitted<br />

driving forces (pusher, tensioning devices, etc.). In these cases, please<br />

consult our technical experts.<br />

More information http://www.igus.de/en/DrylinXpert<br />

Input<br />

Output<br />

Date: Telephone: +49 -2203 - 9649-145<br />

Fax: +49 -2203 - 9649-334<br />

From:<br />

To:<br />

igus ® GmbH<br />

P.O. Box 906123, D-51127 Cologne<br />

Spicher Straße 1a, D-51147 Cologne<br />

Telephone:<br />

Fax:<br />

Application: ................................................................................................................................<br />

...................................................................................................................................................<br />

Current guide system: .................................................................................................................<br />

Orientation of System (1=horizontal, 2=lateral, 3=vertical): ............................................................<br />

Number of bearings per rail/shaft: ............................Number of rails/shafts: .................................<br />

Type of drive: ...........................................................Drive force [N]: ............................................<br />

Average speed:........................................................Maximum speed: .........................................<br />

Length of stroke:......................................................Expected service life: ...................................<br />

Operating time: ...........................................................................................................................<br />

Ambient temperature ...............................................Maximum temperature:.................................<br />

Surrounding medium: ...............................................Lubrication:..................................................<br />

Static Load: .............................................................Dynamic Load:.............................................<br />

<strong>DryLin</strong> ® Analysis<br />

Phone +49- (0) 22 03-96 49-145<br />

Fax +49- (0) 22 03-96 49-334<br />

For the following data, the drawings on the left will help you.<br />

igus ® GmbH<br />

51127 Cologne<br />

<strong>DryLin</strong> ® Analysis<br />

Horizontal Orientation Vertical Orientation Lateral Orientation<br />

sx<br />

sz<br />

Fs<br />

ay<br />

Fa<br />

az<br />

Zero point<br />

y<br />

x<br />

z<br />

az<br />

sy<br />

Fs<br />

z<br />

ay<br />

Fa<br />

Zero point<br />

x<br />

y<br />

z<br />

y<br />

x<br />

Zero point<br />

az<br />

sx<br />

WX<br />

ay<br />

sy<br />

Fs<br />

Fa<br />

Distance between bearings/carriages on a rail/shaft (wx) : .............................................................<br />

Distance between rails/shafts (b) : ................................................................................................<br />

Distance of the mass force in the x-direction (Sx) : ........................................................................<br />

Distance of the mass force in the y-direction (Sy) : ........................................................................<br />

Distance of the mass force in the z-direction (Sz) : ........................................................................<br />

Distance of the drive force in the y-direction (ay) : .........................................................................<br />

Distance of the drive force in the z-direction (az) : .........................................................................<br />

Please enter all the data you know and if possible make a schematic drawing.<br />

mm<br />

Zero point<br />

Internet: www.igus.de<br />

E-mail: info@igus.de<br />

Floating<br />

bearing<br />

b<br />

ay<br />

Fa<br />

Fs<br />

az<br />

sx<br />

Fixed<br />

bearing<br />

sz<br />

WX<br />

Zero point<br />

y<br />

x<br />

z y<br />

x<br />

z<br />

Fixed<br />

bearing<br />

az<br />

sz<br />

b<br />

ay<br />

Fa<br />

Zero point<br />

-<br />

sy<br />

Fs<br />

x<br />

y<br />

z<br />

Floating<br />

bearing<br />

Fixed<br />

bearing<br />

b<br />

sx<br />

az<br />

Fa<br />

ay<br />

sy<br />

Fs<br />

Floating<br />

bearing<br />

x<br />

y<br />

z<br />

246<br />

Lifetime calculation, CAD files and much more support<br />

www.igus.de/en/<strong>DryLin</strong><br />

247