Selecting individual settings<br />

❏<br />

Basic serial interface setting<br />

To select transmission conditions, first choose “Serial interface settings”; then select “Data<br />

length, handshake, or parity.”<br />

Press the FEED button the number of times required to select the desired “Serial interface<br />

settings” used for transmission conditions.<br />

Press FEED button<br />

Setting selected<br />

0 ~ 3 times: No change<br />

4 times: 19200 bps<br />

5 times: 9600 bps<br />

6 times: 4800 bps<br />

7 times: 2400 bps<br />

8 times: 1200 bps<br />

9 or more times: No change<br />

bps: Indicates the number of transmitted bits per second (bps).<br />

❏<br />

Data length, handshake, or parity<br />

Press the FEED button the number of times required to select the desired “Data length,<br />

handshake, or parity” setting used for transmission conditions.<br />

Press FEED button<br />

Setting selected<br />

Data Length Handshake Parity<br />

0 times: No change<br />

1 time: 8 bits DTR/DSR control No parity<br />

2 times: Even<br />

3 times: Odd<br />

4 times: XON/XOFF control No parity<br />

5 times: Even<br />

6 times: Odd<br />

7 times: 7 bits DTR/DSR control No parity<br />

8 times: Even<br />

9 times: Odd<br />

10 times: XON/XOFF control No parity<br />

11 times: Even<br />

12 times: Odd<br />

13 or more times: No change<br />