Selecting individual settings<br />
❏<br />
Basic serial interface setting<br />
To select transmission conditions, first choose “Serial interface settings”; then select “Data<br />
length, handshake, or parity.”<br />
Press the FEED button the number of times required to select the desired “Serial interface<br />
settings” used for transmission conditions.<br />
Press FEED button<br />
Setting selected<br />
0 ~ 3 times: No change<br />
4 times: 19200 bps<br />
5 times: 9600 bps<br />
6 times: 4800 bps<br />
7 times: 2400 bps<br />
8 times: 1200 bps<br />
9 or more times: No change<br />
bps: Indicates the number of transmitted bits per second (bps).<br />
❏<br />
Data length, handshake, or parity<br />
Press the FEED button the number of times required to select the desired “Data length,<br />
handshake, or parity” setting used for transmission conditions.<br />
Press FEED button<br />
Setting selected<br />
Data Length Handshake Parity<br />
0 times: No change<br />
1 time: 8 bits DTR/DSR control No parity<br />
2 times: Even<br />
3 times: Odd<br />
4 times: XON/XOFF control No parity<br />
5 times: Even<br />
6 times: Odd<br />
7 times: 7 bits DTR/DSR control No parity<br />
8 times: Even<br />
9 times: Odd<br />
10 times: XON/XOFF control No parity<br />
11 times: Even<br />
12 times: Odd<br />
13 or more times: No change<br />
3-22 Setup Rev. D