01.01.2015 Views

Training by Schneider Electric - WF Senate

Training by Schneider Electric - WF Senate

Training by Schneider Electric - WF Senate

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Protection/product courses<br />

GenieEvo switchgear<br />

The fundamental principle of controlling danger with the operation of High Voltage (HV) and Low Voltage (LV)<br />

circuit breakers lies at the centre of all networks, from a major transmission system, down to a simple radial LV<br />

distribution board. Failure of a device to operate correctly could result in serious damage and endanger personnel.<br />

These courses enable delegates to grasp the characteristics of these essential products, covering the correct<br />

installation and set up of breakers and its allied protection.<br />

Objectives<br />

@ Delegates will safely operate the circuit breaker to secure the<br />

point of isolation and earthing appropriately<br />

Content<br />

Overview presentation, with notes:<br />

@ Introduction to the switchgear<br />

@ Definition of the main variants and ratings<br />

@ Architecture and main components<br />

@ Evolis vacuum circuit breaker<br />

@ Controlled air disconnector<br />

@ Voltage transformer<br />

@ Endurance characteristics<br />

@ Overview of the Sepam protection system<br />

Target audience<br />

@ Your scope: Public and commercial<br />

buildings<br />

@ Your job: Maintenance manager, electrical<br />

engineer, facilities manager<br />

Prerequisite knowledge<br />

@ None<br />

Duration and delivery<br />

@ A one day course<br />

@ In-class sessions within<br />

<strong>Schneider</strong> <strong>Electric</strong> training centres<br />

@ Can be customised and delivered on<br />

customer premises<br />

Demonstration, followed <strong>by</strong> hands-on operation:<br />

@ Isolator and circuit breaker mechanism operation<br />

@ Cable testing facility<br />

@ Voltage transformer compartment<br />

@ Protection reset<br />

@ Visual checks<br />

Equipment used<br />

@ GenieEvo switchgear<br />

<strong>Training</strong> code: 118<br />

For further information<br />

or registration<br />

@ Contact your local <strong>Schneider</strong> <strong>Electric</strong><br />

customer training centre<br />

10

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!