WALL MOUNTED <strong>WATER</strong> HEATERS<br />

DUAL/SINGLE CIRCUIT <strong>WATER</strong> HEATERS<br />

Model SHZ 30 – 150 LCD electronic comfort<br />

– Type SHZ 30 LCD SHZ 50 LCD SHZ 80 LCD SHZ 100 LCD SHZ 120 LCD SHZ 150 LCD<br />

– Part no. 185452 185453 185454 185455 185456 185457<br />

Application<br />

– Nominal capacity<br />

– For one or more draw-off<br />

l 30 50 80 100 120 150<br />

points (pressure tested)<br />

– For one draw-off point<br />

• • • • • •<br />

(non-pressurised) • • • • • •<br />

Connection details<br />

– Type<br />

– Operating mode<br />

Pressure tested (sealed)<br />

– Dual/single circuit cylinder1) • • • • • •<br />

– Permiss. op. pressure MPa/bar 0.6 / 6<br />

– Mixed water volume of 40 °C2) l<br />

– Stand-by power consumption<br />

59 97 159 198 235 292<br />

at 65 °C /24 h kWh 0.45 0.52 0.66 0.77 0.92 1.05<br />

– Connected load and voltage3) Dual-circuit operation: Single circuit operation: Single heat-up operation:<br />

1/2 kW, 2/2 kW, 1/4 kW, 2/4 kW, 3/4 kW | 1/N/PE ~ 230 V 1 kW, 2 kW, 3 kW, 4 kW | 1/N/PE ~ 230 V 1 kW, 2 kW, 3 kW, 4 kW | 1/N/PE ~ 230 V<br />

1/4 kW, 2/4 kW, 3/4 kW | 2/N/PE ~ 400 V 3 kW, 4 kW | 2/N/PE ~ 400 V 3 kW, 4 kW | 2/N/PE ~ 400 V<br />

1/6 kW, 2/6 kW, 3/6 kW | 3/N/PE ~ 400 V 6 kW | 3/N/PE ~ 400 V 6 kW | 3/N/PE ~ 400 V<br />

– Protection level IP 25 (hoseproof)<br />

– Test symbols VDE / CE<br />

Equipment level<br />

– Steel inner cylinder,<br />

enamel-coated, with prot. anode • • • • • •<br />

– Electronic control unit • • • • • •<br />

– Temperature range °C 20 to 85<br />

– Economy setting °C 40 to 65<br />

– Liquid crystal display • • • • • •<br />

– Impressed current anode • • • • • •<br />

– Colour White<br />

Weight and dimensions<br />

– Dimensions (H x W x D4) ) mm 770 x 410 x 420 740 x 510 x 510 1,050 x 510 x 510 1,050 x 510 x 510 1,210 x 510 x 510 1,445 x 510 x 510<br />

– Wet weight5) kg 53.0 78.0 118.0 140.0 165.0 203.0<br />

Accessories<br />

– Safety valves KV 30, KV 40 for pressure tested, fixtures for non-pressure tested usage (see page 66)<br />

Key<br />

• Available, or yes.<br />

1) Dual-circuit system for reheating during the day, subject to demand.<br />

2) The mixed water volume has a service temperature of 40 °C which is<br />

based on a cold water temperature of 15 °C and a cylinder water<br />

temperature of 65 °C (with respect to the operational state).<br />

3) Regulations vary according to local power supply company; to be<br />

connected only by a qualified electrician – except for units which are<br />

delivered ready to plug in.<br />

4) Including water inlet nozzles (excl. valves).<br />

5) Before installing ensure wall has sufficient load-bearing capacity.<br />