HOT WATER OUR ELEMENT - Stiebel Eltron
HOT WATER OUR ELEMENT - Stiebel Eltron
HOT WATER OUR ELEMENT - Stiebel Eltron
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
WALL MOUNTED <strong>WATER</strong> HEATERS<br />
DUAL / SINGLE CIRCUIT <strong>WATER</strong> HEATERS<br />
Model SH 30 – 150 S electronic HFA-Z 30 – 150 universal<br />
– Type SH 30 S SH 50 S SH 80 S SH 100 S SH 120 S SH 150 S HFA-Z 30 HFA-Z 80 HFA-Z 100 HFA-Z 150<br />
– Part no. 073047 073048 073049 073050 073051 073052 073111 074467 074469 073114<br />
Application<br />
– Nominal capacity l 30 50 80 100 120 150 30 80 100 150<br />
– For one or more draw-off points<br />
(pressure tested)<br />
– For one draw-off point<br />
• • • • • • • • • •<br />
(non-pressurised) • • • • • • • • • •<br />
Connection details<br />
– Type<br />
– Mode of operation<br />
Pressure tested (sealed) Pressure tested (sealed)<br />
– Single circuit cylinder • • • • • • – – – –<br />
– Dual/single circuit cylinder1) – – – – – – • • • •<br />
– Permiss. op. pressure MPa/bar 0.6 / 6 0.6 / 6<br />
– Mixed water volume of 40 °C2) – Stand-by power consumption<br />
l 59 97 159 198 235 292 58 155 195 290<br />
at 65 °C / 24 h kWh 0.45 0.52 0.66 0.77 0.92 1.05 0.5 0.72 0.86 1.2<br />
– Connected load and voltage3) Single circuit operation:<br />
1 kW, 2 kW, 3 kW, 4 kW | 1/N/PE ~ 230 V<br />
3 kW, 4 kW | 2/N/PE ~ 400 V<br />
6 kW | 3/N/PE ~ 400 V<br />
Single heat-up operation:<br />
2 kW, 4 kW | 1/N/PE ~ 230 V<br />
4 kW | 2/N/PE ~ 400 V<br />
6 kW | 3/N/PE ~ 400 V<br />
6 kW | 3/PE ~ 400 V<br />
– Protection level IP 25 (hoseproof) IP 24 (splash-proof)<br />
– Test symbols VDE / CE VDE / CE<br />
Key<br />
• Available, or yes.<br />
1) Dual-circuit system for reheating during the day, subject to demand.<br />
2) The mixed water volume has a service temperature of 40 °C which is<br />
based on a cold water temperature of 15 °C and a cylinder water<br />
temperature of 65 °C (with respect to the operational state).<br />
3) Regulations vary according to local power supply company; to be<br />
connected only by a qualified electrician – except for units which are<br />
delivered ready to plug in.<br />
4) Including water supply connector (excl. valves).<br />
5) Before installing ensure wall has sufficient load-bearing capacity.<br />
Dual-circuit operation: Single circuit operation:<br />
2/4 kW | 1/N/PE ~ 230 V 2 kW, 4 kW | 1/N/PE ~ 230 V<br />
2/4 kW | 2/N/PE ~ 400 V 4 kW | 2/N/PE ~ 400 V<br />
2/6 kW | 3/N/PE ~ 400 V 6 kW | 3/N/PE ~ 400 V<br />
Equipment level<br />
– Steel inner cylinder, enamelcoated,<br />
with prot. anode • • • • • • • • • •<br />
– Temperature range °C 35 to 82 35 to 82<br />
– Economy option Eco °C 60 60<br />
– Signal anode • • • • • • – – – –<br />
– Hot water volume display • • • • • • – – – –<br />
– Colour White White<br />
Weight and dimensions<br />
– Height4) mm 770 740 1,050 1,050 1,210 1,445 770 975 975 1,280<br />
– Width mm 410 510 510 510 510 510 410 510 510 510<br />
– Depth mm 420 510 510 510 510 510 420 510 510 510<br />
– Wet weight5) kg 53.0 78.0 118.0 140.0 165.0 203.0 52.6 113.0 137.5 199.0<br />
Accessories<br />
– Safety valves KV 30, KV 40 for pressure tested, valves for non-pressurised use (see page 66)