WALL MOUNTED STORAGE HEATERS<br />
Model SH 50 – 150 A<br />
– Type SH 50 A SH 80 A SH 100 A SH 120 A SH 150 A SH 100 A UNI SH 120 A UNI SH 150 A UNI<br />
– Part no. 073120 073121 073122 073123 073124 073277 073194 073195<br />
Application<br />
– Nominal capacity<br />
– For one or more draw-off<br />
l 50 80 100 120 150 100 120 150<br />
points (pressure tested)<br />
– For one draw-off point<br />
• • • • • • • •<br />
(non-pressurised) • • • • • • • •<br />
Connection details<br />
– Type<br />
– Operating mode<br />
Pressure tested (sealed)<br />
– Single circuit cylinder • • • • • • • •<br />
– Dual/single circuit cylinder1) – – – – – – – –<br />
– Permiss. op. pressure MPa/bar 0.6 / 6<br />
– Mixed water volume of 40 °C2) – Stand-by power consumption<br />
l 97 159 148 235 292 198 235 292<br />
at 65 °C /24 h kWh 0.53 0.75 0.89 0.93 1.25 0.89 0.93 1.25<br />
– Connected load and voltage3) Single circuit operation: Single circuit operation: Dual-circuit operation:<br />
2 kW | 1/N/PE ~ 230 V 3 kW | 1/N/PE ~ 230 V 1.3 kW, 2.6 kW | 1/N/PE ~ 230 V<br />
3.9 kW | 3/N/PE ~ 400 V<br />
– Protection level IP 25 (hoseproof)<br />
– Test symbols CE<br />
Equipment level<br />
– Steel inner cylinder,<br />
enamel-coated, with prot. anode • • • • • • • •<br />
– Temperature range °C 35 to 82<br />
– Economy option Eco °C 60<br />
– Signal anode – – – – – – – –<br />
– Hot water volume display – – – – – – – –<br />
– Colour White<br />
Weight and dimensions<br />
– Height4) mm 740<br />
– Width mm 510<br />
– Depth mm 510<br />
– Wet weight5) kg 57.0 116.0 137.0 161.0 197.0 138.0 162.6 198.0<br />
Accessories<br />
– Safety valves KV 30, KV 40 for pressure tested<br />
Key<br />
• Available, or yes.<br />
1) Dual-circuit system for reheating during the day, subject to demand.<br />
2) The mixed water volume has a service temperature of 40 °C which is<br />
based on a cold water temperature of 15 °C and a cylinder water<br />
temperature of 65 °C (with respect to the operational state).<br />
3) Regulations vary according to local power supply company; to be<br />
connected only by a qualified electrician – except for units which are<br />
delivered ready to plug in.<br />
4) Including water inlet nozzles (excl. valves).<br />
5) Before installing ensure wall has sufficient load-bearing capacity.<br />
56 | 57