WALL MOUNTED STORAGE HEATERS<br />

Model SH 50 – 150 A<br />

– Type SH 50 A SH 80 A SH 100 A SH 120 A SH 150 A SH 100 A UNI SH 120 A UNI SH 150 A UNI<br />

– Part no. 073120 073121 073122 073123 073124 073277 073194 073195<br />

Application<br />

– Nominal capacity<br />

– For one or more draw-off<br />

l 50 80 100 120 150 100 120 150<br />

points (pressure tested)<br />

– For one draw-off point<br />

• • • • • • • •<br />

(non-pressurised) • • • • • • • •<br />

Connection details<br />

– Type<br />

– Operating mode<br />

Pressure tested (sealed)<br />

– Single circuit cylinder • • • • • • • •<br />

– Dual/single circuit cylinder1) – – – – – – – –<br />

– Permiss. op. pressure MPa/bar 0.6 / 6<br />

– Mixed water volume of 40 °C2) – Stand-by power consumption<br />

l 97 159 148 235 292 198 235 292<br />

at 65 °C /24 h kWh 0.53 0.75 0.89 0.93 1.25 0.89 0.93 1.25<br />

– Connected load and voltage3) Single circuit operation: Single circuit operation: Dual-circuit operation:<br />

2 kW | 1/N/PE ~ 230 V 3 kW | 1/N/PE ~ 230 V 1.3 kW, 2.6 kW | 1/N/PE ~ 230 V<br />

3.9 kW | 3/N/PE ~ 400 V<br />

– Protection level IP 25 (hoseproof)<br />

– Test symbols CE<br />

Equipment level<br />

– Steel inner cylinder,<br />

enamel-coated, with prot. anode • • • • • • • •<br />

– Temperature range °C 35 to 82<br />

– Economy option Eco °C 60<br />

– Signal anode – – – – – – – –<br />

– Hot water volume display – – – – – – – –<br />

– Colour White<br />

Weight and dimensions<br />

– Height4) mm 740<br />

– Width mm 510<br />

– Depth mm 510<br />

– Wet weight5) kg 57.0 116.0 137.0 161.0 197.0 138.0 162.6 198.0<br />

Accessories<br />

– Safety valves KV 30, KV 40 for pressure tested<br />

Key<br />

• Available, or yes.<br />

1) Dual-circuit system for reheating during the day, subject to demand.<br />

2) The mixed water volume has a service temperature of 40 °C which is<br />

based on a cold water temperature of 15 °C and a cylinder water<br />

temperature of 65 °C (with respect to the operational state).<br />

3) Regulations vary according to local power supply company; to be<br />

connected only by a qualified electrician – except for units which are<br />

delivered ready to plug in.<br />

4) Including water inlet nozzles (excl. valves).<br />

5) Before installing ensure wall has sufficient load-bearing capacity.<br />