FREESTANDING DHW CYLINDERS<br />
Model Freestanding<br />
combi cylinder<br />
Freestanding DHW cyl.<br />
with int. heat exchanger<br />
Freestanding<br />
combi cylinder<br />
Kitchen DHW cylinder<br />
– Type SHW 200 S SHW 300 S SHW 400 S SHW 300 WS SHW 400 WS SB 302 S SB 402 S HT 80 S (undersink) 7)<br />
– Part no. 182120 182121 182122 185352 185353 185354 185355 074196<br />
Application<br />
– Nominal capacity l 200 300 400 300 400 300 400 80<br />
Connection details<br />
– Mode of operation<br />
– Single circuit cylinder • • • • • Optional electric flange heater 9) –<br />
– Dual/single circuit cylinder 1) – – – – – Optional electric flange heater 9) •<br />
– Water connection<br />
(external thread) below/above G1" / G1" G1" / G1" G1" / G1" G ½"<br />
– DHW circulation connection G ½" – G ½" –<br />
– Permiss. op. pressure MPa/bar 0.6 / 6 1 / 10 1 / 10 1 / 10<br />
– Mixed water volume of 40 °C 2) l 397 590 792 590 792 – – 140<br />
– Stand-by power consumption<br />
at 65 °C / 24 h kWh 1.5 1.9 2.25 1.9 2.25 – – 1.1<br />
– Connected load and voltage3) Dual-circuit operation: 2/4 kW, 4/4 kW | 1/N/PE ~ 230 V;<br />
2/6 kW, 3/6 kW, 4/6 kW, 6/6 kW | 3/N/PE ~ 400 V<br />
Single circuit operation: 2 kW, 4 kW | 1/N/PE ~ 230 V;<br />
2 kW, 3 kW, 4 kW, 6 kW | 3/N/PE ~ 400 V<br />
Connection for electric heater rod:<br />
G1 ½" (in the upper third)<br />
No. of flange apertures:<br />
2 2<br />
External flange diameter (mm):<br />
ø 210 ø 210<br />
Dual-circuit operation:<br />
1/3 kW, 2/4 kW | 1/N/PE ~ 230 V<br />
2/6 kW | 3/N/PE ~ 400 V<br />
Single circuit operation:<br />
1, 2, 3, 4 kW | 1/N/PE ~ 400 V<br />
6 kW | 3/N/PE ~ 400 V<br />
– Protection level IP 24 (splash-proof) IP 24 (splash-proof) – – IP 24 (splash-proof)<br />
– Test symbols VDE / GS VDE / GS – – VDE / GS<br />
Equipment level<br />
– Thermometer<br />
– Thermal insulation<br />
• • • • • • • –<br />
Permanently fixed/removable<br />
– Steel inner cylinder, enamel-<br />
•/– •/– •/– •/– •/– • /– • /– • /–<br />
coated, with prot. anode<br />
– Display element for<br />
• • • • • • • •<br />
protective anode • • • • • – – •<br />
– Temperature range<br />
– Temperature limit<br />
°C 35 to 82 35 to 82 – – 35 to 82<br />
can be adjusted to °C 45 to 60 45 to 60 – – –<br />
– Integral heat exchanger4) m2 – – – 1.8 – – –<br />
– Colour Pure white / basalt grey Pure white / basalt grey Pure white / basalt grey White side panels<br />
Weight and dimensions<br />
– Height5) mm 1,570 1,585 1,755 1,585 1,755 1,585 1,755 810 – 870 | 850 – 910 8)<br />
– Width mm ø 630 ø 700 ø 750 ø 700 ø 750 ø 700 ø 750 445 | 450 8)<br />
– Depth mm 730 815 865 815 865 – – 550 | 600 8)<br />
– Weight, filled with water6) kg 265 377 490 437 550 401 519 125 | 133 8)<br />
Key<br />
• Available, or yes.<br />
1) Dual-circuit system for reheating during the day, subject to demand.<br />
2) The mixed water volume has a service temperature of 40 °C which is based on a cold<br />
water temperature of 15 °C and a cylinder water<br />
temperature of 65 °C (with respect to the operational state).<br />
3) Regulations vary according to local power supply company; to be connected only by a<br />
qualified electrician – except for units which are delivered ready to plug in.<br />
4) Heat exchanger for the utilisation of additional energy sources, e.g. boiler operation.<br />
5) Before installing ensure wall has sufficient load-bearing capacity.<br />
6) Before installing ensure the floor has sufficient load-bearing capacity.<br />
7) The HT 80 S cylinder for mounting below can be used as a backup unit with the full<br />
casing accessory, part no 074197.<br />
8) With full casing.