COMMERCIAL: INSTANTANEOUS <strong>WATER</strong> HEATERS<br />
FREESTANDING DHW CYLINDERS<br />
Model Inst. water heating cyl. Freestanding combi cylinder Freestanding cylinder<br />
– Type SHD 30 S SHD 100 S SB 602 AC SB 1002 AC SB 650/3 AC SHO AC 600 SHO AC 1000<br />
– Part no. 073059 073060 071554 071282 003039 001414 003352 001415 003353<br />
Application<br />
– Nominal capacity l 30 100 600 1,000 650 600 1,000<br />
– For one or more draw-off points<br />
(pressure tested) • • • • • • • • •<br />
Connection details<br />
– Type<br />
– Mode of operation<br />
Pressure tested (sealed) Pressure tested (sealed) Pressure tested (sealed)<br />
– Inst. water heating cylinder • • – – – – – – –<br />
– Single circuit operation – – Optional electric flange heater (special accessory) • – • –<br />
– Dual/single circuit cylinder1) – Water connection<br />
• • Optional electric flange heater (special accessory) – • – •<br />
(external thread) below/above G ½" G1 ½" / G2" G 1½ "/ G1½" G 1½" / G2"<br />
– DHW circulation connection – – G ½" G ½"<br />
– Permiss. op. pressure MPa/bar 0.6 / 6 1 / 10 0.6 / 6<br />
– Mixed water volume of 40 °C2) – Stand-by power consumption<br />
l 59 195 – – – 1,060 1,860<br />
at 65 °C / 24 h kWh 0.45 0.77 – – – 4.6 5.7<br />
– Connected load and<br />
voltage 3)<br />
Inst. water heating cyl. op.:<br />
3.5/21 kW | 3/PE ~ 400 V<br />
Dual-circuit operation:<br />
3.5/21 kW | 3/PE ~ 400 V<br />
Single circuit operation:<br />
21 kW | 3/PE ~ 400 V<br />
Key<br />
• Available, or yes.<br />
1) Dual-circuit system for reheating during the day, subject to demand.<br />
2) The mixed water volume has a service temperature of 40 °C which is based on a cold<br />
water temperature of 15 °C and a storage water temperature of 65 °C (with respect to<br />
the operational state).<br />
Connection for electric heater rod:<br />
G1 ½" (in the upper third)<br />
No. of flange apertures:<br />
2 2 3<br />
External flange diameter (mm):<br />
ø 280 ø 280 ø 280<br />
7.5 kW<br />
3/PE ~ 400 V<br />
– Protection level IP 25 (hoseproof) – – – IP 24 (splash-proof)<br />
– Test symbols VDE / CE – – – VDE / CE<br />
6/12 kW, 12/12 kW<br />
3/N/PE ~ 400 V<br />
Equipment level<br />
– Thermometer – – • • – • •<br />
– Removable thermal insulation<br />
– Steel inner cylinder, enamel-<br />
– – • • • • •<br />
coated, with prot. anode • • • • • • •<br />
– Display element for prot. anode • • – – – • •<br />
– Temperature range<br />
– Temperature limit<br />
°C 35 to 85 – – – 35 to 85<br />
adjustable to °C – – – – – 45 / 60<br />
– Economy option Eco °C 60 – – – – –<br />
– Colour White<br />
12 kW<br />
3/PE ~ 400 V<br />
Weight and dimensions<br />
– Height4) x width mm 770 x 410 1,050 x 510 1,685 x ø 750 2,525 x ø 750 1,725 x ø 750 1,685 x ø 750 2,525 x ø 750<br />
– Depth mm 420 510 790 790 830 1,000 1,000<br />
– Wet weight5) kg 54.3 140.1 754 1,212 840 760 1,231<br />
Special accessories<br />
– Safety valves KV 30, KV 40 – – – – –<br />
– Foam thermal insulation – – WD 612 WD 1012 WD 650 WD 611 WD 1011<br />
9/18 kW, 18/18 kW<br />
3/N/PE ~ 400 V<br />
3) Regulations vary according to local power supply company; to be connected only by a<br />
qualified electrician.<br />
4) Including water supply connector.<br />
5) Before installing ensure floor has sufficient load-bearing capacity.<br />
62 | 63