COMMERCIAL: INSTANTANEOUS <strong>WATER</strong> HEATERS<br />

FREESTANDING DHW CYLINDERS<br />

Model Inst. water heating cyl. Freestanding combi cylinder Freestanding cylinder<br />

– Type SHD 30 S SHD 100 S SB 602 AC SB 1002 AC SB 650/3 AC SHO AC 600 SHO AC 1000<br />

– Part no. 073059 073060 071554 071282 003039 001414 003352 001415 003353<br />

Application<br />

– Nominal capacity l 30 100 600 1,000 650 600 1,000<br />

– For one or more draw-off points<br />

(pressure tested) • • • • • • • • •<br />

Connection details<br />

– Type<br />

– Mode of operation<br />

Pressure tested (sealed) Pressure tested (sealed) Pressure tested (sealed)<br />

– Inst. water heating cylinder • • – – – – – – –<br />

– Single circuit operation – – Optional electric flange heater (special accessory) • – • –<br />

– Dual/single circuit cylinder1) – Water connection<br />

• • Optional electric flange heater (special accessory) – • – •<br />

(external thread) below/above G ½" G1 ½" / G2" G 1½ "/ G1½" G 1½" / G2"<br />

– DHW circulation connection – – G ½" G ½"<br />

– Permiss. op. pressure MPa/bar 0.6 / 6 1 / 10 0.6 / 6<br />

– Mixed water volume of 40 °C2) – Stand-by power consumption<br />

l 59 195 – – – 1,060 1,860<br />

at 65 °C / 24 h kWh 0.45 0.77 – – – 4.6 5.7<br />

– Connected load and<br />

voltage 3)<br />

Inst. water heating cyl. op.:<br />

3.5/21 kW | 3/PE ~ 400 V<br />

Dual-circuit operation:<br />

3.5/21 kW | 3/PE ~ 400 V<br />

Single circuit operation:<br />

21 kW | 3/PE ~ 400 V<br />

Key<br />

• Available, or yes.<br />

1) Dual-circuit system for reheating during the day, subject to demand.<br />

2) The mixed water volume has a service temperature of 40 °C which is based on a cold<br />

water temperature of 15 °C and a storage water temperature of 65 °C (with respect to<br />

the operational state).<br />

Connection for electric heater rod:<br />

G1 ½" (in the upper third)<br />

No. of flange apertures:<br />

2 2 3<br />

External flange diameter (mm):<br />

ø 280 ø 280 ø 280<br />

7.5 kW<br />

3/PE ~ 400 V<br />

– Protection level IP 25 (hoseproof) – – – IP 24 (splash-proof)<br />

– Test symbols VDE / CE – – – VDE / CE<br />

6/12 kW, 12/12 kW<br />

3/N/PE ~ 400 V<br />

Equipment level<br />

– Thermometer – – • • – • •<br />

– Removable thermal insulation<br />

– Steel inner cylinder, enamel-<br />

– – • • • • •<br />

coated, with prot. anode • • • • • • •<br />

– Display element for prot. anode • • – – – • •<br />

– Temperature range<br />

– Temperature limit<br />

°C 35 to 85 – – – 35 to 85<br />

adjustable to °C – – – – – 45 / 60<br />

– Economy option Eco °C 60 – – – – –<br />

– Colour White<br />

12 kW<br />

3/PE ~ 400 V<br />

Weight and dimensions<br />

– Height4) x width mm 770 x 410 1,050 x 510 1,685 x ø 750 2,525 x ø 750 1,725 x ø 750 1,685 x ø 750 2,525 x ø 750<br />

– Depth mm 420 510 790 790 830 1,000 1,000<br />

– Wet weight5) kg 54.3 140.1 754 1,212 840 760 1,231<br />

Special accessories<br />

– Safety valves KV 30, KV 40 – – – – –<br />

– Foam thermal insulation – – WD 612 WD 1012 WD 650 WD 611 WD 1011<br />

9/18 kW, 18/18 kW<br />

3/N/PE ~ 400 V<br />

3) Regulations vary according to local power supply company; to be connected only by a<br />

qualified electrician.<br />

4) Including water supply connector.<br />

5) Before installing ensure floor has sufficient load-bearing capacity.<br />