IMPORTANT SAFETY INFORMATION<br />
WARNING - Not following these instructions may cause severe injury or death to persons.<br />
Audible Alarm Reset Switch <strong>Installation</strong><br />
<strong>Manual</strong> Reset for the Audible Alarm<br />
UL325 standard requires an audible alarm to go off after two consecutive events<br />
detected by the primary entrapment protection of the gate operator (obstruction sensor).<br />
The audible alarm will continue to sound for 5 minutes or until a stop command<br />
gets actuated.<br />
The Stop command can be actuated in two different forms<br />
1. Using the Built in Stop switch on the Control Box or<br />
2. Using an External Stop button within the sight of the gate, away from moving<br />
parts of the gate and out of reach of children.<br />
3. Controls intended for user activation must be located at least six feet (6’) away<br />
from any moving part of the gate and where the user is prevented from reaching<br />
over, under, around or through the gate to operate the controls. Outdoor or easily<br />
accessible controls shall have a security feature to prevent unauthorized use.<br />
4. The Stop and/or Reset button must be located in the line-of-sight of the gate.<br />
Activation of the reset control shall not cause the operator to start.<br />
6'<br />
STOP<br />
N.O.<br />
COM<br />
STOP<br />
5'<br />
Minimum<br />
+28v<br />
Out of Reach<br />
<strong>Manual</strong> Stop<br />
Radio Station Loop Connector<br />
Button<br />
Open Commands Guard Station Master/Slave<br />
Gnd<br />
Warning N.O. Placard <strong>Installation</strong><br />
Motor Sensor<br />
Low Battery<br />
Radio Station<br />
COM<br />
N.C.<br />
Motor Sensor<br />
Low Battery<br />
+28v<br />
Mag. Lock<br />
Mag.<br />
Lock<br />
Radio<br />
Mag.<br />
Lock<br />
Mag.<br />
Lock<br />
Gnd<br />
+28v<br />
Gnd<br />
UL<br />
Safety Connector<br />
Obstruction<br />
Sensor Center Safety UL Radio<br />
Charger<br />
Loop Loop Sensor Rec.<br />
Power<br />
Gnd<br />
Reopen<br />
Gnd<br />
Center<br />
Gnd<br />
Off 1 Center<br />
Loop<br />
Safety<br />
Loop<br />
UL<br />
Sens<br />
Radio<br />
Rec.<br />
off<br />
1sec<br />
Exit<br />
30sec<br />
Open Commands<br />
Hold Open<br />
Timer<br />
MAX<br />
Gnd<br />
min.<br />
Strike<br />
60sec<br />
Hold Open<br />
Timer<br />
min. MAX<br />
Hold Open<br />
Timer<br />
Obstruction<br />
Sensor<br />
Gnd<br />
Fire<br />
Open<br />
Gnd<br />
Guard Station<br />
Close Stop Open<br />
0 3<br />
Power Radio UL Safety Center<br />
1.5<br />
Obstruction<br />
Charger<br />
Rec. Sensor Loop Loop<br />
Sensor Overlap Delay<br />
of the gate. A minimum of two placards shall be installed. A placard is<br />
Limit<br />
0<br />
1.5<br />
3<br />
Overlap Delay<br />
Open<br />
Stop<br />
Overlap<br />
Delay<br />
All Warning Signs and Placards must be installed where visible in the area<br />
to be installed in the area of each side of the gate and be visible.<br />
30<br />
60<br />
Open<br />
Stop<br />
Stop<br />
Close<br />
Close<br />
Limit<br />
GND<br />
Close<br />
Open<br />
Stop<br />
Close<br />
Master/Slave<br />
GND<br />
UL<br />
Siren<br />
UL<br />
Siren<br />
Siren<br />
Brake<br />
Brake<br />
Brake<br />
8<br />
TECHNICAL SUPPORT 1 800 908 0884<br />
OPEN<br />
OPEN