IMPORTANT SAFETY INFORMATION<br />

WARNING - Not following these instructions may cause severe injury or death to persons.<br />

Audible Alarm Reset Switch <strong>Installation</strong><br />

<strong>Manual</strong> Reset for the Audible Alarm<br />

UL325 standard requires an audible alarm to go off after two consecutive events<br />

detected by the primary entrapment protection of the gate operator (obstruction sensor).<br />

The audible alarm will continue to sound for 5 minutes or until a stop command<br />

gets actuated.<br />

The Stop command can be actuated in two different forms<br />

1. Using the Built in Stop switch on the Control Box or<br />

2. Using an External Stop button within the sight of the gate, away from moving<br />

parts of the gate and out of reach of children.<br />

3. Controls intended for user activation must be located at least six feet (6’) away<br />

from any moving part of the gate and where the user is prevented from reaching<br />

over, under, around or through the gate to operate the controls. Outdoor or easily<br />

accessible controls shall have a security feature to prevent unauthorized use.<br />

4. The Stop and/or Reset button must be located in the line-of-sight of the gate.<br />

Activation of the reset control shall not cause the operator to start.<br />

6'<br />

STOP<br />

N.O.<br />

COM<br />

STOP<br />

5'<br />

Minimum<br />

+28v<br />

Out of Reach<br />

<strong>Manual</strong> Stop<br />

Radio Station Loop Connector<br />

Button<br />

Open Commands Guard Station Master/Slave<br />

Gnd<br />

Warning N.O. Placard <strong>Installation</strong><br />

Motor Sensor<br />

Low Battery<br />

Radio Station<br />

COM<br />

N.C.<br />

Motor Sensor<br />

Low Battery<br />

+28v<br />

Mag. Lock<br />

Mag.<br />

Lock<br />

Radio<br />

Mag.<br />

Lock<br />

Mag.<br />

Lock<br />

Gnd<br />

+28v<br />

Gnd<br />

UL<br />

Safety Connector<br />

Obstruction<br />

Sensor Center Safety UL Radio<br />

Charger<br />

Loop Loop Sensor Rec.<br />

Power<br />

Gnd<br />

Reopen<br />

Gnd<br />

Center<br />

Gnd<br />

Off 1 Center<br />

Loop<br />

Safety<br />

Loop<br />

UL<br />

Sens<br />

Radio<br />

Rec.<br />

off<br />

1sec<br />

Exit<br />

30sec<br />

Open Commands<br />

Hold Open<br />

Timer<br />

MAX<br />

Gnd<br />

min.<br />

Strike<br />

60sec<br />

Hold Open<br />

Timer<br />

min. MAX<br />

Hold Open<br />

Timer<br />

Obstruction<br />

Sensor<br />

Gnd<br />

Fire<br />

Open<br />

Gnd<br />

Guard Station<br />

Close Stop Open<br />

0 3<br />

Power Radio UL Safety Center<br />

1.5<br />

Obstruction<br />

Charger<br />

Rec. Sensor Loop Loop<br />

Sensor Overlap Delay<br />

of the gate. A minimum of two placards shall be installed. A placard is<br />

Limit<br />

0<br />

1.5<br />

3<br />

Overlap Delay<br />

Open<br />

Stop<br />

Overlap<br />

Delay<br />

All Warning Signs and Placards must be installed where visible in the area<br />

to be installed in the area of each side of the gate and be visible.<br />

30<br />

60<br />

Open<br />

Stop<br />

Stop<br />

Close<br />

Close<br />

Limit<br />

GND<br />

Close<br />

Open<br />

Stop<br />

Close<br />

Master/Slave<br />

GND<br />

UL<br />

Siren<br />

UL<br />

Siren<br />

Siren<br />

Brake<br />

Brake<br />

Brake<br />

8<br />

TECHNICAL SUPPORT 1 800 908 0884<br />

OPEN<br />

OPEN

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!