LIMIT SWITCH SET-UP<br />

STEP 4<br />

Press both limit switches at the same time to<br />

initiate the set-up (the open and close LEDs<br />

will blink on the Control Board).<br />

Click!<br />

Click!<br />

Activate Both<br />

Limit Switches<br />

At the Same Time<br />

STEP 5<br />

Open and close the gate from limit to limit<br />

without interruption for two complete cycles.<br />

2X<br />

STEP 6<br />

Fully Open and Close<br />

the Gate 2 Times<br />

Use the Fine Tune Limit Pot to perform minor adjustments to the closed position.<br />

6"<br />

Initial Setting<br />

2-1/2"<br />

First Adjustment<br />

1/2"<br />

Fully Open and Close the Gate<br />

After Every Adjustment<br />

Second Adjustment<br />