TROUBLESHOOTING<br />

Gate opens. Closes or stops on its own<br />

Make sure that the ‘Charger’<br />

LED is on and not flashing,<br />

indicating that there is AC<br />

power.<br />

Check that your wires from<br />

your accessories are:<br />

a) Not shorting together<br />

b) Not shorting a power line<br />

c) Not shorting to metal or<br />

earth ground.<br />

‘Charger’ LED off. Gate does not run - alarm sounds upon any input command<br />

Check the 4 Amp fuse on the<br />

control board.<br />

Check the 3 Amp fuse on the<br />

EMI control board. Refer to<br />

page 14.<br />

Make sure the incoming AC<br />

line is properly connected.<br />

Refer to page 14.<br />

Check the incoming high<br />

voltage power supply.<br />

Check the proper selection of<br />

power supply (120/220 VAC).<br />

Refer to page 14.<br />

Verify the EMI board by<br />

reading high voltage across the<br />

(4) blue and red wires at the<br />

terminal block connections.<br />

Battery voltage reads zero or very low<br />

Ensure the batteries are connected as follows:<br />

a) Left battery - Black terminal connected to the black wire from the harness (jacketed wire)<br />

b) Left battery - Red terminal connected to the red wire from fuse holder<br />

c) Right battery - Black terminal connected to the red wire from fuse holder<br />

d) Right battery - Red terminal connected to the red wire from the harness (jacketed wire)<br />