TROUBLESHOOTING Qualified Technicians Only<br />

Unplug Appliance Before Performing Any Troubleshooting or Maintenance<br />

PROBLEM CAUSE(S) SOLUTIONS<br />

4. <strong>Pellet</strong>s will not The hopper is empty.<br />

Refill hopper.<br />

feed.<br />

The auger motor or circuit board, air Check to be sure that there is no blockage in the pressure tap or<br />

inlet high limit switch or pressure hose. Have your authorized Lennox Hearth Products dealer diag-<br />

switch may be defective. The pressure<br />

switch tap or hose may be blocked.<br />

nose the problem and clean or replace any necessary parts.<br />

Back pressure in venting tripping pres- If new installation check for excessive 90˚ bends, long horizontal<br />

sure switch.<br />

runs or excessive vertical run of 3” pipe. Possibly change to 4” pipe.<br />

If older installation check for excessive ash accumulation in pipe or<br />

other obstructions. Clean out pipe.<br />

Thermostat is in stand-by mode. Check to see if thermostat is set too low or if sun is shining directly<br />

on thermostat.<br />

Thermostat wires disconnect.<br />

Re-install wires.<br />

High limit switch may have been<br />

tripped.<br />

Allow stove to cool. Increase convection blower setting.<br />

Self-aligning bearings in auger motor<br />

may be misaligned.<br />

Gently tap the auger motor.<br />

Auger is Jammed<br />

Unplug stove. Remove the rear inspection panel (freestanding<br />

model). Hold auger motor gearbox in both hands and rock it back<br />

and forth to release the auger. If this is unsuccessful, then contact<br />

your authorized Lennox Hearth Products dealer.<br />

Auger Motor Setscrew is loose. Tighten setscrew.<br />

Pressure switch is sensing back pres- Remove left side panel (freestanding model) and locate the orange<br />

sure in the vent system and shutting rubber hose that attaches the pressure switch to the exhaust<br />

off the auger motor.<br />

blower. Disconnect the rubber hose from orifice on blower housing.<br />

If the auger starts to feed, the pressure switch is sensing back pressure.<br />

After test, reconnect hose to blower (NEVER operate the appliance<br />

with hose removed). Clean venting system and exhaust flow<br />

passages as outlined in Routine Maintenance section of this manual.<br />

Note: Multiple elbows are more susceptible to collecting ash<br />

resulting in restriction<br />

5. Blowers will not The low limit disc has failed in the Have your authorized Lennox Hearth Products dealer replace the<br />

shut off after the fuel<br />

has been switched<br />

off and the stove has<br />

cooled down.<br />

closed position.<br />

low limit disc.<br />

6. Blowers will not There is no power to the stove. Check that the stove is plugged in to the wall outlet. Ensure that<br />

operate when the<br />

there is power to the outlet (test by plugging in a lamp into same<br />

start button is de-<br />

outlet).<br />

pressed.<br />

There is no power to the control board. Check to see if your circuit breaker has tripped.<br />

Check the wire connections on the high limit disc and control board.<br />

7. One or both blow- Both the room air blower and the ex- Ensure the room air blower is adjusted to a setting at least as high<br />

ers shut off for no haust blower have an over-heat pro- as or higher than the fuel fee setting. If the blower motor continues<br />

apparent reason. tector (high limit disc) built into them. If to shut down, clean blower intake (see Routine Maintenance). If this<br />

the temperature of the blower motor<br />

exceeds the high limit temperature,<br />

then the motor shuts down.<br />

does not correct the problem, replace the blower.<br />

8. Stove will not light. The igniter element may have failed.<br />

There are not enough pellets in the<br />

UltraGrate TM Check igniter element fuse in rear stove compartment. Call your<br />

authorized Lennox Hearth Products dealer. See alternate manual<br />

lighting procedure<br />

.<br />

Prime the feed system (see Starting Your <strong>Pellet</strong> Stove on page 22).<br />

Improper damper setting.<br />

Adjust damper (see page 23 Damper Operation and page 24<br />

Damper Adjustment Guidelines).<br />