14.01.2015 Views

equipment sourcebook - Loctite.ph

equipment sourcebook - Loctite.ph

equipment sourcebook - Loctite.ph

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Wand Systems<br />

<strong>Loctite</strong>® ZETA® light cure wand systems are used for the continuous or batch processing of assemblies that<br />

require curing in small areas. These cost effective systems provide a variety of curing attributes. Selection of a<br />

<strong>Loctite</strong>® ZETA® wand system is based on the required lamp intensity and the number and length of the light<br />

guides needed as well as the need for continuous intensity monitoring or measuring. The time required to<br />

complete the curing process depends primarily on the offset distance from the end of the light guide to the<br />

surface of the adhesive, and the type of adhesive being used.<br />

LIGHT CURE Wand Systems<br />

PRODUCT<br />

<strong>Loctite</strong> ® Indigo 7720<br />

Visible Light Wand System<br />

<strong>Loctite</strong> ® ZETA ® 7735<br />

UV Wand Systems<br />

<strong>Loctite</strong> ® ZETA ® 7740<br />

UV Wand Systems<br />

<strong>Loctite</strong> ® ZETA ® 7760<br />

UV Wand Systems<br />

Item Number 98633 98317A / 958216 98157A / 958228 98450 / 958239<br />

Useful Curing Diameter 1 ⁄4" to 1" 1 ⁄4" to 1" 1 ⁄4" to 1" 1 ⁄4" to 1"<br />

Light Guides Specific guides are required for each wand. See individual wand descriptions on pages 105-107.<br />

Lamp Type<br />

100 watt Metal Halide<br />

50 watt High Pressure<br />

Mercury Arc<br />

100 watt High Pressure<br />

Mercury Arc<br />

200 watt High Pressure<br />

Mercury Arc<br />

Typical Intensity* 1.0 to 1.5 W/cm 2 5 to 7 W/cm 2 9 to 11W/cm 2 16 to 20 W/cm 2<br />

Optimized Spectral<br />

Output Range<br />

Visible UVA, B, C UVA, B, C UVA, B, C<br />

Spectral Wavelength – 250 to 410 nm 250 to 410 nm 250 to 410 nm<br />

Replacement Bulb<br />

(Item Number / Type)<br />

98635 – Lamp / Reflector<br />

Module, 100 W Metal Halide<br />

98339 – Lamp / Reflector<br />

Module, 50 W (HPMA)<br />

Additional Accessories Sold Separately<br />

984818 – Lamp / Reflector<br />

Module, 100 W (HPMA)<br />

98451– Lamp / Reflector<br />

Module, 200 W (HPMA)<br />

LOCTITE ® LIGHT INTENSITY MONITOR<br />

Item Number: 891494<br />

Digital light lntensity monitoring option<br />

for <strong>Loctite</strong>® UV Wands 958216, 958228<br />

and 958239 only.<br />

LOCTITE ® ZETA ® 7021 SPOT RADIOMETER<br />

Item Number: 98048<br />

Effective monitoring of UV wand curing<br />

system performance. See page 114.<br />

* Exact output measurement is dependent on the brand and calibration method of the meter used.<br />

Spectral Output of <strong>Loctite</strong> ® ZETA ® 7735<br />

50 Watt High Pressure Mercury Arc Lamp<br />

Spectral Output of <strong>Loctite</strong> ® ZETA ® 7740<br />

100 Watt High Pressure Mercury Arc Lamp<br />

Relative Irradiance<br />

1.0<br />

0.8<br />

0.6<br />

0.4<br />

0.2<br />

0<br />

225 250 275 300 325 350 375 400 425 450 475 500<br />

Wavelength in nm<br />

Relative Irradiance<br />

1.0<br />

0.8<br />

0.6<br />

0.4<br />

0.2<br />

0<br />

225 250 275 300 325 350 375 400 425 450 475 500<br />

Wavelength in nm<br />

Spectral Output of <strong>Loctite</strong> ® ZETA ® 7760 Mercury Arc Bulb<br />

Spectral Output of <strong>Loctite</strong> ® ZETA ® 7760 Mercury Arc Bulb with<br />

Optional Filter Kit 98598 to Optimize Tack-Free Surface Cure<br />

Relative Output %<br />

Relative Output %<br />

240 260 280 300 320 340 360 380 400 420 440<br />

Wavelength in nm<br />

230 250 270 290 310 330 350 370 390 410 430<br />

Wavelength in nm<br />

For additional information and the full line of <strong>equipment</strong>, visit www.<strong>equipment</strong>.loctite.com.<br />

103

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!