equipment sourcebook - Loctite.ph
equipment sourcebook - Loctite.ph
equipment sourcebook - Loctite.ph
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Wand Systems<br />
<strong>Loctite</strong>® ZETA® light cure wand systems are used for the continuous or batch processing of assemblies that<br />
require curing in small areas. These cost effective systems provide a variety of curing attributes. Selection of a<br />
<strong>Loctite</strong>® ZETA® wand system is based on the required lamp intensity and the number and length of the light<br />
guides needed as well as the need for continuous intensity monitoring or measuring. The time required to<br />
complete the curing process depends primarily on the offset distance from the end of the light guide to the<br />
surface of the adhesive, and the type of adhesive being used.<br />
LIGHT CURE Wand Systems<br />
PRODUCT<br />
<strong>Loctite</strong> ® Indigo 7720<br />
Visible Light Wand System<br />
<strong>Loctite</strong> ® ZETA ® 7735<br />
UV Wand Systems<br />
<strong>Loctite</strong> ® ZETA ® 7740<br />
UV Wand Systems<br />
<strong>Loctite</strong> ® ZETA ® 7760<br />
UV Wand Systems<br />
Item Number 98633 98317A / 958216 98157A / 958228 98450 / 958239<br />
Useful Curing Diameter 1 ⁄4" to 1" 1 ⁄4" to 1" 1 ⁄4" to 1" 1 ⁄4" to 1"<br />
Light Guides Specific guides are required for each wand. See individual wand descriptions on pages 105-107.<br />
Lamp Type<br />
100 watt Metal Halide<br />
50 watt High Pressure<br />
Mercury Arc<br />
100 watt High Pressure<br />
Mercury Arc<br />
200 watt High Pressure<br />
Mercury Arc<br />
Typical Intensity* 1.0 to 1.5 W/cm 2 5 to 7 W/cm 2 9 to 11W/cm 2 16 to 20 W/cm 2<br />
Optimized Spectral<br />
Output Range<br />
Visible UVA, B, C UVA, B, C UVA, B, C<br />
Spectral Wavelength – 250 to 410 nm 250 to 410 nm 250 to 410 nm<br />
Replacement Bulb<br />
(Item Number / Type)<br />
98635 – Lamp / Reflector<br />
Module, 100 W Metal Halide<br />
98339 – Lamp / Reflector<br />
Module, 50 W (HPMA)<br />
Additional Accessories Sold Separately<br />
984818 – Lamp / Reflector<br />
Module, 100 W (HPMA)<br />
98451– Lamp / Reflector<br />
Module, 200 W (HPMA)<br />
LOCTITE ® LIGHT INTENSITY MONITOR<br />
Item Number: 891494<br />
Digital light lntensity monitoring option<br />
for <strong>Loctite</strong>® UV Wands 958216, 958228<br />
and 958239 only.<br />
LOCTITE ® ZETA ® 7021 SPOT RADIOMETER<br />
Item Number: 98048<br />
Effective monitoring of UV wand curing<br />
system performance. See page 114.<br />
* Exact output measurement is dependent on the brand and calibration method of the meter used.<br />
Spectral Output of <strong>Loctite</strong> ® ZETA ® 7735<br />
50 Watt High Pressure Mercury Arc Lamp<br />
Spectral Output of <strong>Loctite</strong> ® ZETA ® 7740<br />
100 Watt High Pressure Mercury Arc Lamp<br />
Relative Irradiance<br />
1.0<br />
0.8<br />
0.6<br />
0.4<br />
0.2<br />
0<br />
225 250 275 300 325 350 375 400 425 450 475 500<br />
Wavelength in nm<br />
Relative Irradiance<br />
1.0<br />
0.8<br />
0.6<br />
0.4<br />
0.2<br />
0<br />
225 250 275 300 325 350 375 400 425 450 475 500<br />
Wavelength in nm<br />
Spectral Output of <strong>Loctite</strong> ® ZETA ® 7760 Mercury Arc Bulb<br />
Spectral Output of <strong>Loctite</strong> ® ZETA ® 7760 Mercury Arc Bulb with<br />
Optional Filter Kit 98598 to Optimize Tack-Free Surface Cure<br />
Relative Output %<br />
Relative Output %<br />
240 260 280 300 320 340 360 380 400 420 440<br />
Wavelength in nm<br />
230 250 270 290 310 330 350 370 390 410 430<br />
Wavelength in nm<br />
For additional information and the full line of <strong>equipment</strong>, visit www.<strong>equipment</strong>.loctite.com.<br />
103