CNSX-K SERIES<br />

Combination, FVNR, NEMA Configuration<br />

Enclosure Ratings: NEMA 7/9 Mfg: Killark<br />

1/4 HP - 200 HP (575V)<br />

Standard Features:<br />

• NEMA rated Contactor with Adjustable Thermal Overload (Class10).<br />

• Oversized Control Power Transformer (<strong>opt</strong>ional).<br />

• External Machined Flange Joint Design.<br />

• Units are assembled, pre-wired and ready to go straight out of the box.<br />

• Integral Cast Mounting Feet.<br />

• Units come <strong>standard</strong> with Hinged Covers.<br />

• S.S. 316 Captive Quick Thread Cover Bolts (<strong>opt</strong>ional).<br />

• Ground Lug Package.<br />

• Steel mounting pan.<br />

• Enclosures cast from Copper-Free Aluminum – Max 0.25% Copper Content.<br />

• Aluminum, Stainless Steel Shot or Sandblasted Natural Finish.<br />

• Enclosures suitable for NEMA 4X Applications.<br />

• Cast aluminum and Stainless Steel Hinge.<br />

• <strong>Inc</strong>ludes a Molded Case Circuit Breaker and external operating handle.<br />

OVERALL<br />

MOUNTING<br />

NEMA<br />

SIZE<br />

1<br />

2<br />

3<br />

4<br />

5<br />

HP<br />

0.25 HP<br />

0.5<br />

0.75<br />

1<br />

1.5<br />

2<br />

3<br />

5<br />

7.5<br />

10<br />

15<br />

20<br />

25<br />

30<br />

40<br />

50<br />

60<br />

75<br />

100<br />

125<br />

150<br />

200<br />

FULL LOAD AMPS @<br />

OVERALL<br />

OVERALL<br />

BASE PART NUMBER<br />

LIST PRICE<br />

575V/3PHASE/60HZ<br />

DIMENSIONS<br />

MOUNTING<br />

FULL LOAD AMPS @<br />

DIMENSIONS<br />

0.64 23”H x 14.5”W x 9.125”D<br />

BASE PART NUMBER LIST PRICE<br />

OVERALL MOUNTING<br />

21.375”H x 7”W CH-CNSX-K-0.25-575-000000 $4,001.00<br />

0.9<br />

23”H x 14.5”W x 9.125”D 21.375”H x 7”W CH-CNSX-K-0.5-575-000000 $4,001.00<br />

1.3<br />

23”H x 14.5”W x 9.125”D 21.375”H x 7”W CH-CNSX-K-0.75-575-000000 $4,001.00<br />

1.7<br />

23”H x 14.5”W x 9.125”D 21.375”H x 7”W CH-CNSX-K-1-575-000000 $4,001.00<br />

2.4<br />

23”H x 14.5”W x 9.125”D 21.375”H x 7”W CH-CNSX-K-1.5-575-000000 $4,001.00<br />

2.7<br />

23”H x 14.5”W x 9.125”D 21.375”H x 7”W CH-CNSX-K-2-575-000000 $4,001.00<br />

3.9<br />

23”H x 14.5”W x 9.125”D 21.375”H x 7”W CH-CNSX-K-3-575-000000 $4,001.00<br />

6.1<br />

23”H x 14.5”W x 9.125”D 21.375”H x 7”W CH-CNSX-K-5-575-000000 $4,001.00<br />

9<br />

23”H x 14.5”W x 9.125”D 21.375”H x 7”W CH-CNSX-K-7.5-575-000000 $4,063.00<br />

11<br />

23”H x 14.5”W x 9.125”D 21.375”H x 7”W CH-CNSX-K-10-575-000000 $4,063.00<br />

17 25.5”H x 14.5”W x 9.125”D 21.875”H x 7”W CH-CNSX-K-15-575-000000 $5,232.00<br />

22 25.5”H x 14.5”W x 9.125”D 21.875”H x 7”W CH-CNSX-K-20-575-000000 $5,233.00<br />

27 25.5”H x 14.5”W x 9.125”D 21.875”H x 7”W CH-CNSX-K-25-575-000000 $5,343.00<br />

32 27.25”H x 17.875”W x 11”D 25.625”H x 10.375”W CH-CNSX-K-30-575-000000 $9,657.00<br />

41 27.25”H x 17.875”W x 11”D 25.625”H x 10.375”W CH-CNSX-K-40-575-000000 $9,657.00<br />

52 27.25”H x 17.875”W x 11”D 25.625”H x 10.375”W CH-CNSX-K-50-575-000000 $9,657.00<br />

62 34.25”H x 21.5”W x 11.875”D 32.625”H x 14”W CH-CNSX-K-60-575-000000 $13,300.00<br />

77 34.25”H x 21.5”W x 11.875”D 32.625”H x 14”W CH-CNSX-K-75-575-000000 $13,300.00<br />

99 34.25”H x 21.5”W x 11.875”D 32.625”H x 14”W CH-CNSX-K-100-575-000000 $13,672.00<br />

125 62.25”H x 20.25”W x 15”D 43.5”H x 18.5”W CH-CNSX-K-125-575-000000 $25,628.00<br />

144 62.25”H x 20.25”W x 15”D 43.5”H x 18.5”W CH-CNSX-K-150-575-000000 $25,860.00<br />

192 62.25”H x 20.25”W x 15”D 43.5”H x 18.5”W CH-CNSX-K-200-575-000000 $25,860.00<br />

Units are shipped with overload relays sized for <strong>standard</strong> NEMA rated motors with a service factor of 1.15, running at normal speeds and with<br />

Full Load Amp (FLA) rating as shown in the table on page 5. For non-<strong>standard</strong> motors or motors with service factors less than 1.15, contact<br />

CORDYNE with the motor nameplate rating so the overload relay can be properly sized.<br />

Non-Standard Options: Many additional Options such as Control Relays for “Dry Circuit” control from PLC’s, Timers, Remote Operating<br />

Stations, etc., are available. Contact CORDYNE for those special requirements. We can make any custom modification or addition to suit<br />

your application.<br />

UL 508A & UL 1203 Certification Optional. Available upon request.<br />

Please contact factory for pricing information.<br />

118<br />

SPECIFICATIONS AND PRICES ARE SUBJECT TO CHANGE WITHOUT NOTICE<br />

CORDYNE, INC., 9820 DRYSDALE LN, HOUSTON, TEXAS 77041, 1-800-324-1484 OR 713-460-5151 FAX 713-460-5186 WWW.CORDYNE.COM | WWW.STORE.CORDYNE.COM<br />