Linear actuators DC versions<br />

CAR 22<br />

Suitable cont<strong>ro</strong>l units and accessories<br />

Dimensional drawing<br />

Cont<strong>ro</strong>l Limit<br />

unit switch<br />

†104<br />

CAED 5-24R<br />

CAXB 22*<br />

3<br />

D12B<br />

D24B<br />

M10 1,5<br />

53<br />

Hand switch<br />

Foot switch<br />

Desk switch<br />

* See page 379<br />

CAES 31C<br />

35<br />

†22<br />

L = S + 205<br />

66,5<br />

49<br />

16<br />

26<br />

†10 e8<br />

Connecting diagram<br />

89<br />

46<br />

23<br />

16,5<br />

60<br />

23<br />

12/24 V DC<br />

+<br />

3<br />

1<br />

3 1 2<br />

2<br />

Limit<br />

switch<br />

Limit<br />

switch<br />

1 2<br />

M<br />

Legend:<br />

S = st<strong>ro</strong>ke<br />

L = retracted length<br />

Technical data<br />

Unit CAR 22<br />

Rated push load N 1 000 to 1 500<br />

Rated pull load N 1 000 to 1 500<br />

Speed (full load to no load) mm/s 10 to 30<br />

St<strong>ro</strong>ke mm 50 to 300<br />

Retracted length mm S+ 205<br />

Voltage V DC 12 or 24<br />

Power consumption W N/A<br />

Current consumption 12 V DC A 9<br />

24 V DC A 5<br />

Duty cycle % 25<br />

Ambient temperature °C –20 to +70<br />

Type of p<strong>ro</strong>tection IP 44<br />

Weight kg 1,2 to 1,6<br />