22.01.2015 Views

PM CTP CAT M EA P 4 X 3 v01 | 2009-02-01 - Industrial GP - ro

PM CTP CAT M EA P 4 X 3 v01 | 2009-02-01 - Industrial GP - ro

PM CTP CAT M EA P 4 X 3 v01 | 2009-02-01 - Industrial GP - ro

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Telescopic pillars AC versions<br />

Telesmart TXG<br />

Suitable cont<strong>ro</strong>l units and accessories<br />

Dimensional drawing<br />

2<br />

150<br />

EHE1<br />

STF*<br />

STA*<br />

120<br />

55<br />

120<br />

190<br />

140<br />

TXG 4<br />

TXG 5<br />

TXG 8<br />

TXG 9<br />

Hand switch<br />

Foot switch<br />

Desk switch<br />

Integrated cont<strong>ro</strong>l unit<br />

Integrated cont<strong>ro</strong>l unit<br />

Integrated cont<strong>ro</strong>l unit<br />

Integrated cont<strong>ro</strong>l unit<br />

* only with FCC plug<br />

St<strong>ro</strong>ke ±2<br />

10<br />

Supporting<br />

plate<br />

†9<br />

140<br />

R 300<br />

180<br />

4¥M6¥40 DIN 7 500<br />

included<br />

Connecting diagram<br />

Retracted length ±2<br />

(without mounting plates)<br />

120<br />

120/230 V AC<br />

L<br />

N<br />

PE<br />

Supporting<br />

plate<br />

150<br />

120<br />

85<br />

4¥M6¥40 DIN 7 500<br />

included<br />

220<br />

190<br />

170<br />

10<br />

†9<br />

M<br />

Legend:<br />

S = st<strong>ro</strong>ke<br />

L = retracted length<br />

Note: mounting plates are not included.<br />

To be ordered separately.<br />

Technical data<br />

Unit TXG4/5 TXG8/9<br />

Rated push load N 1 500 1 500<br />

Rated pull load N 0 0<br />

Bending load Nm up to 210 1) up to 210 1)<br />

Speed (full load to no load) mm/s 17 to 23 17 to 23<br />

Telescopic pillar version # of section 2-section 2-section<br />

St<strong>ro</strong>ke mm 200 to 600 200 to 600<br />

Retracted length mm S+180 S+180<br />

Voltage V AC 120 230<br />

Power W N/A N/A<br />

Current A 1,8 0,9<br />

Duty cycle: intermittent operation min. 1 min./9 min. 1 min./9 min.<br />

Duty cycle: short-time operation min. N/A N/A<br />

Ambient temperature °C +10 to +40 +10 to +40<br />

Type of p<strong>ro</strong>tection IP 30 30<br />

P<strong>ro</strong>tection class – II/(I) 2) II/(I) 2)<br />

Type of cont<strong>ro</strong>l – electrical electrical<br />

Weight kg 9 to 14 9 to 14<br />

1) For details, see bending load diagrams<br />