. Auto Log – the flowmeter will store the reading at a programmed interval set by the<br />
user. The reading is stored in a file called <strong>Flow</strong>data.csv which is accessible via the<br />
USB connection to a laptop or PC. Note - removing the batteries without the meter<br />
being connected to a USB device will wipe any recorded data.<br />
To set up Auto Logging press the or arrow keys until Auto Log is<br />
selected then press<br />
SEL<br />
The display will now show<br />
Log <strong>In</strong>terval<br />
00 mins<br />
The cursor will be under the tens-of-units digit. Use the or buttons to<br />
select the required tens of minutes. Confirm with<br />
The display will now show<br />
Set Logging<br />
c. New Data – The logged data is stored as a “comma separated values file”. New Data<br />
simply starts a new line in the data file by inserting a Carriage Return (CR LF) to start<br />
a new line in the file for the new data.<br />
SEL<br />
To set up New Data press the or arrow keys until New Data is selected<br />
then press<br />
SEL<br />
The display will now show<br />
Set Logging<br />
d. Clear Data – Clear Data deletes ALL the data from the <strong>Flow</strong>data.csv file and sets the<br />
logging ‘file pointer’ back to zero. Be careful using this option.<br />
To Clear Data press the or arrow keys until Clear Data is selected then<br />
press<br />
SEL<br />
The display will now show Set Logging<br />
e. Logging Off – turns off all logging.<br />
To set Logging Off press the or arrow keys until Logging Off is<br />
selected then press<br />
SEL<br />
The display will now show Set Logging<br />
6