Squirrel-cage motors<br />
Technical information<br />
General information<br />
■ Order number (continued)<br />
Overview of "Special designs"<br />
The order codes for the individual motors can be found in the "Selection and ordering data".<br />
2<br />
Order code Special designs For detailed<br />
information<br />
see<br />
Page<br />
Windings and motor protection<br />
A10 Motor protection with PTC thermistors for converter-fed<br />
2/17, 2/44<br />
operation with three embedded tempera-<br />
ture sensors for alarm in zones<br />
A11 Motor protection with PTC thermistors with three<br />
embedded temperature sensors for tripping<br />
2/17, 2/18,<br />
2/47<br />
A12 Motor protection with PTC thermistors with six 2/17<br />
embedded temperature sensors for alarm and<br />
tripping<br />
A15 Motor protection with PTC thermistors for converter-fed<br />
2/17<br />
operation with three embedded tempera-<br />
ture sensors for tripping<br />
A16 Motor protection with PTC thermistors for converter-fed<br />
2/17<br />
operation with six embedded temperature<br />
sensors for alarm and tripping<br />
A23 Motor temperature detection with embedded 2/44<br />
temperature sensor KTY 84-130<br />
A25 Motor temperature detection with embedded 2/44<br />
temperature sensors 2 x KTY 84-130<br />
A60 Installation of 3 PT 100 G resistance thermometers –<br />
A61 Installation of 6 PT 100 G resistance thermometers –<br />
A72 Installation of 2 PT 100 screw-in resistance<br />
thermometers (basic circuit) for rolling-contact<br />
bearings<br />
C11 Used acc. to temp. class F (up to CT 40 °C) with<br />
service factor<br />
C12 Used acc. to temp. class F (up to CT 40 °C) with<br />
increased power rating<br />
C13 Used acc. to temp. class F with increased coolant<br />
temperature<br />
Y52 Used acc. to temp. class F –<br />
other requirements<br />
–<br />
2/17, 2/44<br />
2/17, 2/44<br />
2/17, 2/44<br />
2/17<br />
Paint finish<br />
K23 Unpainted (only cast iron parts primed) 2/5<br />
K24 Unpainted, only primed 2/5<br />
K26 Special paintwork in RAL 7030 stone grey 2/5<br />
K27 Special paintwork in RAL 6011 mignonette green 2/5<br />
K28 Special paintwork in RAL 7031 bluish grey 2/5<br />
L42 Special paintwork in RAL 7032 pebble grey 2/5<br />
L43 Special paintwork in RAL 9005 jet black 2/5<br />
M16 Special paintwork in RAL 1002 sand yel<strong>low</strong> 2/5<br />
M17 Special paintwork in RAL 1013 pearl white 2/5<br />
M18 Special paintwork in RAL 3000 flame red 2/5<br />
M19 Special paintwork in RAL 6021 pale green 2/5<br />
M20 Special paintwork in RAL 7001 silver grey 2/5<br />
M21 Special paintwork in RAL 7035 light grey 2/5<br />
M22 Special paintwork in RAL 9001 cream 2/5<br />
M23 Special paintwork in RAL 9002 grey white 2/5<br />
Order code Special designs For detailed<br />
information<br />
see<br />
Page<br />
Design for zones in accordance with ATEX<br />
M34 Version for Zone 21 for mains-fed operation 2/9<br />
M35 Version for Zone 22 for mains-fed operation 2/9<br />
M38 Version for Zone 21 for converter-fed operation 2/9<br />
M39 Version for Zone 22 for converter-fed operation 2/9<br />
M72<br />
M73<br />
Version for Zone 2 for mains-fed operation 2/9<br />
EEx nA II T3 acc. to EN 50 021, Ex nA II T3 acc. to<br />
IEC 60 079-15<br />
Version for Zone 2 for converter-fed operation 2/9<br />
EEx nA II T3 acc. to EN 50 021, Ex nA II T3 acc. to<br />
IEC 60 079-15<br />
Distributed drive systems<br />
G55 ECOFAST motor plug Han-Drive 10e for 230 Vd/ 2/46<br />
400 VY<br />
G56 ECOFAST motor plug, EMC resistant,<br />
2/46<br />
Han Drive 10e, 230 Vd/400 V*<br />
H90 MICROSTARTER – direct on-line starter with 2/47<br />
24 V DC control with metric M25 cable entries<br />
H91 MICROSTARTER – direct on-line starter with 2/47<br />
24 V DC control, with HAN Q8 plug connectors<br />
H92 MICROSTARTER – direct on-line starter with AS- 2/47<br />
Interface connection, with metric M25 cable entries<br />
H93 MICROSTARTER – direct on-line starter with AS- 2/47<br />
Interface connection, with HAN Q8 plug connectors<br />
(ECOFAST)<br />
H94 MICROSTARTER – reversing starter with AS-Interface<br />
2/47<br />
connection, with metric M25 cable entries<br />
H95 MICROSTARTER – reversing starter with AS-Interface<br />
2/47<br />
connection, with HAN Q8 plug connector<br />
(ECOFAST)<br />
Marine version – "Operation under deck"<br />
E00 Not certified,<br />
6/2<br />
to ABS 50 °C/CCS 45 °C/RINA 45 °C<br />
temperature class F used acc. to F<br />
E11 Certified according to GL (Germanischer Lloyd) 6/2<br />
Germany, CT 45 °C, temperature class F used<br />
acc. to F<br />
E21 Certified according to LRS (Lloyds Register of 6/2<br />
Shipping), Great Britain, CT 45 °C, temperature<br />
class F used acc. to F<br />
E31 Certified according to BV (Bureau Veritas), France 6/2<br />
CT 45 °C, temperature class F used acc. to F<br />
E51 Certified according to DNV (Det Norske Veritas), 6/2<br />
Norway, CT 45 °C, temperature class F used acc. to F<br />
E61 Certified according to ABS<br />
6/2<br />
(American Bureau of Shipping), USA, CT 50 °C,<br />
temperature class F used acc. to F<br />
E71 Certified according to CCS<br />
6/2<br />
(Chinese Classification Society), China, CT 45 °C,<br />
temperature class F used acc. to F<br />
E80 Motor for use in shipping,<br />
higher ambient temperature and/or<br />
used as F in accordance with B<br />
6/3<br />
Y54 Special paintwork in other colors: RAL .... 2/5<br />
Y53 Normal paint finish in other colors: RAL .... 2/5<br />
Siemens M 11 · 2003/2004 2/3