Squirrel-cage motors<br />

Technical information<br />

Converter-fed operation<br />

In general, all motors are suitable<br />

for converter-fed opera-<br />

2<br />

tion. Some motors require special<br />

measures.<br />

The planning notes for drives<br />

with a constant or square-law<br />

counter-torque are contained in<br />

the fol<strong>low</strong>ing catalogues:<br />

MICROMASTER:<br />

Catalogue series DA 64 and<br />

DA 51<br />

SIMOVERT MASTERDRIVES:<br />

Catalogue series DA 65<br />

These catalogues also contain<br />

tables showing which squirrelcage<br />

motors should be assigned<br />

to which SIMOVERT<br />

converter, depending on the<br />

load characteristic of the driven<br />

machine.<br />

■All data specified in Catalogue<br />

M11 applies to 50 Hz supply<br />

systems.<br />

Attention should be paid to the<br />

reduction factors for constanttorque<br />

drives, pump drives and<br />

compressor drives.<br />

Motor temperature detection<br />

KTY 84 temperature sensor:<br />

Order Code:<br />

A23 = 1 x KTY 84-130,<br />

A25 = 2 x KTY 84-130<br />

This sensor is a PTC thermistor.<br />

Its resistance varies as a function<br />

of the temperature in accordance<br />

with a defined curve.<br />

Some Siemens converters calculate<br />

the motor temperature<br />

according to the resistance of<br />

the temperature sensor. They<br />

can be set to a user-definable<br />

temperature for alarms and<br />

tripping.<br />

The 1LA8 motors are supplied<br />

without the standard PTC thermistor<br />

if Order Code A23 is<br />

specified.<br />

The temperature sensor is embedded<br />

in the motor winding<br />

overhang in the same way as a<br />

PTC thermistor. The evaluation<br />

is effected by the converter, for<br />

example.<br />

The 3RS10 temperature monitoring<br />

device belonging to the<br />

protection device can be ordered<br />

separately for mains-fed<br />

operation. For further details<br />

see Catalogue CA 01 Order No.<br />

E86060-D4001-A110-C1-7600.<br />

Motor protection<br />

All standard 1LA and 1LG motors<br />

for Zones 2, 21, and 22 for<br />

converter-fed operation are already<br />

fitted with a PTC thermistor<br />

for tripping. It is also possible<br />

to order a PTC thermistor<br />

for alarm for converter-fed operation<br />

(Order Code A10).<br />

Insulation<br />

The insulation of 1LA and 1LG<br />

motors is such that they can operate<br />

unrestrictedly in converter-fed<br />

mode up to <strong>voltage</strong>s of<br />

ˆ 500 V. The same applies to<br />

operation with pulse-controlled<br />

AC converters with <strong>voltage</strong> front<br />

times t s > 0.1 ms at the motor terminals.<br />

Providing these conditions are<br />

met, all motors with <strong>voltage</strong><br />

codes 1, 3, 5, and 6 can be operated<br />

in converter-fed mode,<br />

except for those with <strong>voltage</strong><br />

ratings of > 500 V to 690 V,<br />

which are supplied with special<br />

insulation for operation with a<br />

pulse-controlled AC converter<br />

(SIMOVERT MASTERDRIVES,<br />

MM440 > 500 V – 600 V) but<br />

without a converter circuit (du/dt<br />

filter or sine filter) (10th position<br />

of the Order No. = "M").<br />

For operation with a converter at<br />

the outputs specified in the catalogue,<br />

the motors are utilized<br />

according to temperature class<br />

F. Order Codes C11, C12 and<br />

C13 are not possible.<br />

Connection of the motors<br />

In addition to the restrictions applying<br />

to mains-connected machines,<br />

the maximum permissible<br />

conductor cross-sections<br />

for the converter must also be<br />

kept in mind when the motors<br />

are connected.<br />

Ventilation/<br />

noise<br />

Increased fan noise may occur<br />

in self-ventilated motors at<br />

speeds higher than the rated<br />

speed.<br />

To increase motor utilization for<br />

<strong>low</strong> speeds, it is advisable to<br />

use separately ventilated motors<br />

such as 1LA5, 1LA7, 1LG,<br />

and 1LG6 with Order Code G17<br />

or motor 1PQ8.<br />

Mechanical stress, grease life<br />

Due to the higher speeds beyond<br />

the rated speed value and<br />

the resulting increased vibration,<br />

the mechanical balance<br />

quality changes and the bearings<br />

are under greater mechanical<br />

stress. This reduces the<br />

grease life and the bearing life.<br />

(enquire if necessary).<br />

Bearings<br />

To avoid damage by bearing<br />

currents, isolated bearings for<br />

frame sizes 225 to 315 are available<br />

and recommended for<br />

frame size 280 (Order Code<br />

L27) 1 ). These are standard in<br />

1LA8 motors for converter-fed<br />

operation on SIMOVERT<br />

MASTERDRIVES (9 th position<br />

of the Order No. = "P").<br />

3<br />

M1-5178<br />

R<br />

2<br />

k<br />

1<br />

D = 2 mA<br />

0<br />

0<br />

100<br />

°C<br />

200<br />

T U<br />

300<br />

1) For 1MJ7 motors, Order Code<br />

L27 can be used for frame sizes<br />

250 to 315.<br />

2/44<br />

Siemens M 11 · 2003/2004