2<br />

Squirrel-cage motors<br />

Technical information<br />

Mechanical design<br />

Type of construction to DIN EN 60 034-7 Size Code<br />

Standard flange<br />

12th position<br />

Order Code<br />

IM B 14/IM 3601,<br />

IM V 19/IM 3631,<br />

IM V 18/IM 3611<br />

without canopy<br />

56 M to 160 L 2 2 ) –<br />

IM V 18/IM 3611<br />

with canopy<br />

63 M to 160 L 9 1 ) 2 ) M2A<br />

IM B 34/IM 2101<br />

56 M to 160 L 7 2 ) –<br />

Custom flange<br />

IM B 14/IM 3601,<br />

IM V 19/IM 3631,<br />

IM V 18/IM 3611<br />

without canopy<br />

56 M to 160 L 3 3 ) –<br />

IM V 18/IM 3611<br />

with canopy<br />

63 M to 160 L 9 1 ) 3 ) M2B<br />

IM B 34/IM 2101<br />

56 M to 160 L 9 3 ) M2C<br />

The standard flanges are assigned to the frame sizes as FT with threaded holes in DIN EN 50 347.<br />

C-flanges acc. to DIN 42 948 are still valid.<br />

The custom flange was assigned as large flange in the previous DIN 42 677.<br />

All types of construction within the fol<strong>low</strong>ing series have equal dimensions:<br />

IM B3, IM B6, IM B7, IM B8, IM V5, and IM V6<br />

IM B5, IM V1, and IM V3<br />

IM B14, IM V18, and IM V19<br />

The motors in the standard power range are available in the standard types of construction IM B3, IM B5 or IM B14, and can be operated<br />

in mounting positions IM B6, IM B7, IM B8, IM V5, IM V6, IM V1, IM V3 (up to frame size 160 L) or IM V18 and IM V19. Eyebolts are available<br />

for transport and installation in a horizontal position. In conjunction with the eyebolts, for the purpose of stabilizing the position when the<br />

motor is arranged vertically, additional lifting straps (DIN EN 1492-1) and/or clamping bands (DIN EN 12195-2) must be used. If mounting<br />

position IM V1 is ordered, eyebolts are supplied for vertical mounting.<br />

■On the normal rating plate, therefore, they are marked with only the basic type of construction.<br />

■If foot-type motors larger than frame size 180 M are mounted to the wall, it is recommended<br />

that especially the motor feet are supported.<br />

For all motors with the shaft end pointing downwards,<br />

the version "with canopy" is recommended;<br />

see Section "Technical Information", "Degrees of protection".<br />

For explosion-proof motors:<br />

For types of construction with shaft end pointing downwards,<br />

the version "with canopy" is mandatory.<br />

Types of construction with shaft end pointing upwards must be<br />

suitably covered in order to avoid that small parts<br />

fall into the fan cowl.<br />

(See also Section 17 DIN EN 50 014).<br />

The cooling may not be impaired by the cover.<br />

1) Second K16 shaft extension not<br />

available.<br />

2) For 1MJ6 motors only possible<br />

for frame size 90.<br />

3) For 1MJ6 motors only possible<br />

for frame size 80.<br />

2/26<br />

Siemens M 11 · 2003/2004