Technical Description ________________________________________________________________<br />
Digital Input/Output<br />
Basic QML201 Logger<br />
In addition to digital frequency/counter inputs (2 + 1 pcs), analog<br />
inputs can be used <strong>for</strong> monitoring digital state. Furthermore, the state<br />
status in<strong>for</strong>mation can be used <strong>for</strong> controlling one of the excitation<br />
voltages, e.g. as a contact enclosure that can be activated by an event.<br />
Optional QMI108 Digital I/O Module<br />
The digital inputs <strong>and</strong> outputs of QMD108 are freely <strong>and</strong> individually<br />
configurable by the user.<br />
Hardware Setup View: Digital I/O Configuration<br />
The Hardware Setup view also provides the possibility to select<br />
which outputs are controlled by Timers. The on/off cycle <strong>for</strong> the<br />
selected outputs can then be configured in the Timers view. The other<br />
possibility to control the outputs is to use alarms, <strong>for</strong> example, to<br />
activate the output signal when the alarm condition is met. The alarm<br />
condition is configured in the Alarms view.<br />
The following template shows an example of the Timers view. In the<br />
example the configuration is as follows:<br />
- Output 0 toggles between on <strong>and</strong> off in a one minute cycle.<br />
- Output 5 is on <strong>for</strong> one minute be<strong>for</strong>e each full hour.<br />