Chapter 7 _______________________________________________________Operating environment<br />
CHAPTER 7<br />
OPERATING ENVIRONMENT<br />
The <strong>MAWS</strong> HydroMet systems have been especially designed <strong>for</strong><br />
unattended operation at remote locations. Only minimum maintenance<br />
is required annually.<br />
Operating temperature<br />
The <strong>MAWS</strong> systems have a wide operating temperature of -35° to +<br />
55° C (extended range at request). When installed outside, it is<br />
recommended that the enclosure is equipped with a white radiation<br />
shield, efficiently protecting the enclosure against excessive sun<br />
radiation, falling ice in tower installations etc. The shield also<br />
minimizes the temperature differences between day <strong>and</strong> night, thus<br />
preventing condensation inside the enclosure. This, together with the<br />
GoreTex membrane filter, guarantees that no extra drying agent bags<br />
are required inside the enclose to keep it dry.<br />
Bottom of the Enclosure<br />
VAISALA ________________________________________________________________________ 61