Chapter 10 ____________________________________________________________ Technical Data<br />

Solar Panels<br />

SOLAR12 Solar Panel Specifications<br />

Property<br />

Description / Value<br />

Peak power (Pp)<br />

12 W<br />

@ 1 kW/m 2 @ +25 °C<br />

Guaranteed min. peak 10.8 W<br />

power<br />

Voltage @ peak power 16.7 V<br />

(Vpp), typical<br />

Current @ peak power 0.72 A<br />

(Ipp), typical<br />

Short-circuit current (Isc), 0.8 A<br />

typical<br />

Temperature coefficient of 0.25 mA/°C<br />

current<br />

Operating temperature -40 °C ... +85 °C<br />

Dimensions (in mm) 268 × 540 × 15<br />

Weight<br />

1.5 kg<br />

Output cable<br />

6 m, 2 × 1.55 mm 2 , incl.<br />

SOLAR24 Solar Panel Specifications<br />

Property<br />

Description / Value<br />

Peak power (Pp)<br />

24 W<br />

@ 1 kW/m 2 @ +25 °C<br />

Guaranteed min. peak 21.6 W<br />

power<br />

Voltage @ peak power 16.7 V<br />

(Vpp), typical<br />

Current @ peak power 1.44 A<br />

(Ipp), typical<br />

Short-circuit current (Isc), 1.6 A<br />

typical<br />

Temperature coefficient of 0.5 mA/°C<br />

current<br />

Operating temperature -40 °C ... +85 °C<br />

Dimensions (in mm) 327 × 674 × 34<br />

Weight<br />

3.2 kg<br />

Output cable<br />

6 m, 2 × 1.55 mm 2 , incl.<br />

VAISALA ________________________________________________________________________ 73