Chapter 3 __________________________________________________________________ Software<br />
• Controlling powering of the telemetry devices according to the user<br />
configured schedule whenever the charging of the back-up batteries<br />
from the solar panel is OFF.<br />
• Reducing the telecommunication rate whenever the system works<br />
on back-up batteries.<br />
• Reducing the sampling rate whenever the system works on back-up<br />
batteries.<br />
The low power monitoring is an intelligent algorithm taking into<br />
account the charging state of the back-up batteries <strong>and</strong> repeated mains<br />
power failures.<br />
Power monitoring of telemetry<br />
devices<br />
The <strong>MAWS</strong> station offers intelligent power monitoring features <strong>for</strong><br />
guaranteeing extended operation. When there is a failure in supplying<br />
primary power to a remote station, the <strong>MAWS</strong> system can be<br />
configured to switch off the power from the telemetry device <strong>for</strong> most<br />
of that time. In order to conserve the back-up battery capacity, the<br />
power can be switched on at user-defined times <strong>for</strong> a short period to<br />
transmit an alarm or other critical data. Whenever the primary power<br />
is recovered, the telemetry device will again be powered normally.<br />
Dynamically Controlled Timer Function<br />
<strong>MAWS</strong> application execution is mostly controlled by timers, which<br />
are configured to fixed intervals using the <strong>MAWS</strong> Lizard Setup<br />
Software.<br />
Timer intervals controlled by thresholds provide the means to change<br />
these intervals dynamically according to limit values (thresholds)<br />
while the system is running. Each measured <strong>and</strong>/or calculated data<br />
item can be configured to be monitored by thresholds.<br />
For example, the following topics can be h<strong>and</strong>led using this control<br />
method:<br />
- Power consumption control when operating on backup batteries.<br />
<strong>MAWS</strong> can keep the communication equipment permanently on<br />
when external AC-power/solar charging is available, <strong>and</strong> switch to<br />
VAISALA ________________________________________________________________________ 41