Chapter 10 ____________________________________________________________ Technical Data<br />

CHAPTER 10<br />

TECHNICAL DATA<br />

QML201 Logger<br />

QML201 Logger Specifications<br />

Property<br />

Processor<br />

A/D conversion<br />

Data logging memory<br />

Sensor inputs<br />

Typical accuracy across<br />

measured temperature<br />

range –50 °C ... +80 °C<br />

Maximum error across<br />

measured temperature<br />

range –35 °C ... +50 °C<br />

Description / Value<br />

32 bit Motorola<br />

16 bit<br />

1.7 Mbytes internal Flash memory<br />

Several hundreds Mbytes on optional<br />

Compact Flash memory card<br />

10 Analog inputs (20 single ended inputs)<br />

2 counter / frequency inputs<br />

Internal channel <strong>for</strong> PMT16A pressure<br />

transducer<br />

Better than ± 0.06 °C<br />

Less than ± 0.12 °C<br />

Maximum error at 0 °C Less than ± 0.06 °C<br />

Voltage measurement With factory calibration:<br />

±2.5V range<br />

Better than 0.04 % reading ± 150 µV<br />

±250mV range<br />

Better than 0.04 % reading ± 20 µV<br />

±25mV range<br />

Better than 0.04 % reading ± 6 µV<br />

±6.5mV range<br />

Better than 0.12 % reading ± 6 µV<br />

Frequency measurements 0.003 % + resolution 241 nsec (up to 10 kHz)<br />

Common mode range<br />

Real-time clock<br />

St<strong>and</strong>ard<br />

With GPS option<br />

Serial communication<br />

St<strong>and</strong>ard<br />

Optional<br />

+5 V / -4 V<br />

Better than 20 sec/month<br />

Configurable, default 5 sec/month<br />

One RS-232, one RS-485<br />

Two (2) optional plug-in slots <strong>for</strong><br />

communication modules to increase the<br />

number of serial I/O channels up to 7 pcs<br />