INTEGRATED TRANSMITTER RTD ASSEMBLY<br />

SANITARY TEMPERATURE SENSOR WITH EXTENSION CABLE<br />

ITS22 assemblies are<br />

particularly useful where<br />

extreme operating conditions<br />

exist in wash down situations<br />

and very wet environments.<br />

While external cables will<br />

withstand wash downs,<br />

to further protect the sensor<br />

and ensure longer life,<br />

stainless steel armor or<br />

overbraid can be custom added<br />

to prevent abrasion wear.<br />

1.5” Std.<br />

4.0”<br />

To order the ITS22 with a 90° bend,<br />

add suffix “B” after the model number.<br />

Ex: ITS22B<br />

CODE TABLE 1: Calibrated Temperature Range<br />

CODE<br />

TABLE 5: Probe Length “L”<br />

05<br />

0˚C to 50˚C (32/122˚F)<br />

In 0.1 inch increments<br />

10<br />

0˚C to 100˚C (32/212˚F)<br />

---<br />

Ex: 065 = 6.5” long<br />

15<br />

0˚C to 150˚C (32/302˚F)<br />

Ex: 120 = 12.0” long<br />

20<br />

55<br />

51<br />

52<br />

0˚C to 200˚C (32/392˚F)<br />

-50˚C to 50˚C (-58/122˚F)<br />

-50˚C to 150˚C (-58/302˚F)<br />

-50˚C to 200˚C (-58/392˚F)<br />

CODE<br />

N _ _<br />

TABLE 6: Extension Length “C”<br />

In 0.1” increments (1.0” Std.)<br />

Ex: N20 = 2.0” long<br />

XX Custom Temperature Range CODE<br />

TABLE 7: Fitting Type<br />

XX = Specify Temperature Range in Description<br />

T15 Tri-Clamp, 1.5” (16 AMP)<br />

T20<br />

Tri-Clamp, 2” (16AMP)<br />

Integrated Transmitter RTD Assemblies are factory<br />

T25 Tri-Clamp, 2.5” (16 AMP)<br />

calibrated to an accuracy of ± 0.25% of span or better.<br />

CODE<br />

TABLE 2: Output<br />

T30 Tri-Clamp, 3” (16 AMP)<br />

Other fittings available. Consult factory.<br />

LP 4-20 mA loop, upscale burnout (std.) CODE TABLE 8: Extension Cable Type<br />

LD<br />

CODE<br />

4-20 mA loop, downscale burnout<br />

TABLE 3: Probe Diameter “D”<br />

PV<br />

PVC insulation,<br />

90°C (195°F) max.<br />

D<br />

F<br />

1/4”<br />

3/8”<br />

TF<br />

Teflon insulation,<br />

200°C (392°F) max.<br />

H<br />

CODE Sheath O.D.<br />

1/2”<br />

Tip O.D.<br />

TA<br />

Teflon with Stainless Steel armor,<br />

200°C (392°F) max.<br />

DB<br />

FC<br />

1/4”<br />

3/8”<br />

1/8”<br />

3/16”<br />

TB<br />

Teflon with Stainless Steel overbraid,<br />

200°C (392°F) max.<br />

HC<br />

1/2”<br />

3/16”<br />

CODE TABLE 9: Extension Cable Length “E”<br />

HD<br />

JD<br />

1/2”<br />

5/8”<br />

1/4”<br />

1/4”<br />

---<br />

In Inches<br />

Ex: 060 = 60” long<br />

Other diameters available. Consult factory.<br />

CODE<br />

TABLE 4: Probe Material<br />

CODE<br />

TABLE 10: Surface Finish<br />

S Stainless Steel 316<br />

S<br />

Standard<br />

Other materials available. Consult factory.<br />

P<br />

Pharmaceutical<br />

PART NUMBER SEQUENCE i.e. ITS22-05-LP-DB-S-065-N20-T15-PV-060-S<br />

Enter CODE From Tables<br />

0.12 R<br />

min.<br />

“L”<br />

Sanitary Cap<br />

“C”<br />

1.5” Std. 2.5” Std.<br />

ITS22<br />

ITS22 - Table 1 - Table 2 - Table 3 - Table 4 - Table 5 - Table 6 - Table 7 - Table 8 - Table 9 -<br />

Model Number Temp Output Probe Probe Probe Extension Fitting Extension Extension<br />

Range<br />

Diameter Material Length Length Type Cable Type Cable Length<br />

190 Detroit Street • Cary, Illinois 60013 • Phone: 847-639-5600 • Fax: 847-639-2199 • Web: www.durexindustries.com • TOLL FREE: 800-762-3468<br />

“E”<br />

3.0” Std.<br />

Table 10<br />

Surface<br />

Finish<br />

167