FLANGE IMMERSION HEATER INSTALLATION AND OPERATION<br />

BEFORE INSTALLING:<br />

1. Unpack the heater at the place of installation. Inspect the heater for shipping damage and report any<br />

claims to the carrier. Do not operate damaged equipment.<br />

2. Check the nameplate watt and volt rating against your supply voltage and capacity and the<br />

requirements of your installation.<br />

MOUNTING<br />

1. Most Flanged heaters are designed for direct immersion<br />

into a liquid. Heater tubes must be installed into the system<br />

so that the tubes are covered by liquid at all times during<br />

operation. Care should be taken to avoid air entrapment or<br />

pockets of overheated �uid around the heater tubes.<br />

INSTALLATION INSTRUCTIONS<br />

2. Flanged heaters mounted into tanks should be installed<br />

horizontally near the tank bottom to allow natural circulation.<br />

Agitation of the liquid in the tank will improve system<br />

performance. Heaters should be located to avoid sludge build<br />

around the heater tubes.<br />

3. Circulating or forced �ow systems must have unrestricted �ow<br />

to ensure proper control performance, heater life, and system<br />

integrity.<br />

Minimum Liquid Level<br />

Maximum Sludge Level<br />

Locate heater<br />

as low<br />

as possible<br />

WIRING<br />

1. Heater should be properly grounded to prevent<br />

electrical shock hazard.<br />

2. Do not support or suspend heater from termination<br />

or wiring.<br />

3. Make sure the heater supply voltage is the same as the<br />

rated heater voltage.<br />

4. System should include a �ow switch, low liquid level<br />

cut-o� switch, over temperature switch, or other safety<br />

device (depending on type of system). Heater tubes<br />

designed for direct immersion will fail if operated in air.<br />

5. Do not exceed 105% of rated voltage. Higher voltages<br />

result in higher wattage output which could damage<br />

the heater, system, or medium heated.<br />

6. All wiring should be done in accordance with the<br />

National Electrical Code and applicable local codes.<br />

7. Refer to the typical wiring diagrams on pages 45 and 46<br />

for the proper method of connecting the heater.<br />

8. The current carrying capacity of the power supply leads<br />

should exceed the heater amperage by at least 25%. Be<br />

sure to consider the ambient operating temperature<br />

and apply the appropriate correction factor to the<br />

ampacity rating of the wire. Lead wire used must be<br />

rated for 150°C minimum.<br />