228<br />
TRANSMITTER TECHNICAL DATA<br />
INPUT<br />
Resistance thermometer (RTD)<br />
Input Designation Measurement Range Limits Min. Span<br />
to IEC 751<br />
(α = 0.00385)<br />
to DIN 43760<br />
(α = 0.00618)<br />
Resistance transmitter (Ω)<br />
Resistance (Ω)<br />
Pt100<br />
Pt500<br />
Pt1000<br />
Ni100<br />
Ni500<br />
Ni1000<br />
Connection type<br />
-328 to 1562 °F (-200 to 850 °C)<br />
-328 to 482 °F (-200 to 250 °C)<br />
-328 to 482 °F (-200 to 250 °C)<br />
-76 to 356 °F (-60 to 180 °C)<br />
-76 to 302 °F (-60 to 150 °C)<br />
-76 to 302 °F (-60 to 150 °C)<br />
18 °F (10 °C)<br />
18 °F (10 °C)<br />
18 °F (10 °C)<br />
18 °F (10 °C)<br />
18 °F (10 °C)<br />
18 °F (10 °C)<br />
2-, 3- or 4-wire connection<br />
cable resistance compensation possible in the 2 wire<br />
system (0 to 20Ω)<br />
Sensor cable resistance max. 11 Ω per cable<br />
Sensor current ≤ 0.6 mA<br />
Designation Measurement Range Limits<br />
Thermocouples (TC)<br />
10 to 400 Ω<br />
10 to 2000 Ω<br />
Input Designation Measurement Range Limits<br />
to NIST<br />
Monograph<br />
175,<br />
IEC 584<br />
to ASTM<br />
E988<br />
to DIN 43710<br />
Voltage transmitters (mV)<br />
Designation<br />
Type B (PtRh30-PtRh6) [1]<br />
Type E(NiCr-CuNi)<br />
Type J (Fe-CuNi)<br />
Type K (NiCr-Ni)<br />
Type N (NiCrSi-NiSi)<br />
Type R (PtRh13-Pt)<br />
Type S(PtRh10-Pt)<br />
Type T (Cu-CuNi)<br />
Type C (W5Re-W26Re)<br />
Type D (W3Re-W25Re)<br />
Type L (Fe-CuNi)<br />
Type U (Cu-CuNi)<br />
Cold junction<br />
Accuracy of cold<br />
junction<br />
Sensor current<br />
32 to 3308 °F (0 to +1820 °C)<br />
-328 to 1679 °F (-200 to + 915 °C)<br />
-328 to 2192 °F (-200 to +1200 °C)<br />
-328 to 2501 °F (-200 to +1372 °C)<br />
-454 to 2372 °F (-270 to +1300 °C)<br />
32 to 3214 °F (0 to +1768 °C)<br />
32 to 3214 °F (0 to +1768 °C)<br />
-328 to 752 °F (-200 to + 400 °C)<br />
32 to 4208 °F (0 to +2320 °C)<br />
32 to 4523 °F (0 to +2495 °C)<br />
-328 to 1652 °F (-200 to +900 °C)<br />
-328 to 1112 °F (-200 to +600 °C)<br />
internal (Pt100)<br />
or external , 32 to 176 °F (0 to 80 °C)<br />
Measurement Range Limits<br />
± 1.8 °F (± 1 °C)<br />
Min.<br />
Measurement<br />
Range<br />
10 Ω<br />
100 Ω<br />
Min.<br />
Measurement<br />
Range<br />
900 °F (500 °C)<br />
90 °F (50 °C)<br />
90 °F (50 °C)<br />
90 °F (50 °C)<br />
90 °F (50 °C)<br />
900 °F (500 °C)<br />
900 °F (500 °C)<br />
90 °F (50 °C)<br />
900 °F (500 °C)<br />
900 °F (500 °C)<br />
90 °F (50 °C)<br />
90 °F (50 °C)<br />
190 Detroit Street • Cary, Illinois 60013 • Phone: 847-639-5600 • Fax: 847-639-2199 • Web: www.durexindustries.com • TOLL FREE: 800-762-3468<br />
30 nA<br />
[1] High measuring error increase for temperature lower than 572 °F (300 °C)<br />
Min.<br />
Measurement<br />
Range<br />
Millivolt transmitter (mV) -10 to 100 mV 5 mV