CALIBRATION SERVICES<br />

THERMOCOUPLE CALIBRATION<br />

<strong>Durex</strong> offers testing at standard<br />

temperatures for determination of<br />

initial calibration tolerances for<br />

thermocouples. All calibration tests<br />

are fully traceable to the National<br />

Institute of Standards and Technology<br />

(NIST). Calibration is also available for application<br />

Calibration (T/C Type) Temperatures Available Applicable Specifications<br />

E, J, K, N, T 32˚F to 2300˚F ASTM E 207<br />

(0˚C to 1250˚C) ASTM E 220<br />

B, R, S 32˚ F to 3000˚F ASTM E 230<br />

(0˚C to 1649˚C) ANSI MC 96.1<br />

E, K, N, T -320˚F & -110˚F to 23˚F<br />

(-196˚C & -79˚C to 0˚C)<br />

temperatures other than the standard points in a range from -110°F to 3000°F (-79°C to 1650°C)<br />

depending on material. Certificates are supplied for all items calibrated.<br />

<strong>Durex</strong> manufactures thermocouple assemblies in the following calibrations:<br />

190 Detroit Street • Cary, Illinois 60013 • Phone: 847-639-5600 • Fax: 847-639-2199 • Web: www.durexindustries.com • TOLL FREE: 800-762-3468