Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
328<br />
9<br />
Submersible Pumps<br />
The difference between the submersible pumps and the all-purpose<br />
pumps is obvious at first glance, as no separate suction hose or suction<br />
basket are needed on the submersible pumps.<br />
Submersed in the liquid to be pumped, the submersible pump can<br />
be operated either upright or on its side. Thanks to the series flatsuction<br />
device, the liquid can be pumped off down to a remaining<br />
depth of only 5 mm. And when we claim that the submersible<br />
pumps are also exceptionally robust, we can prove it — their special<br />
sliding-ring seal makes them completely safe to run dry. This type<br />
of seal makes it possible to dispense with an oil-chamber. Unlike<br />
other makes of pump, then, there is no need to check or change the<br />
oil here. Yet more safety and reliability is provided by the plasticembedded<br />
motor winding. If the fluid being pumped should penetrate<br />
the motor compartment, no danger and no great damage results.<br />
One very important fact is that not only the cable but also the entire<br />
pump is designed to be oil-proof. And because e.g. floods do not<br />
always choose to happen in places where there are 3-phase AC<br />
Type<br />
(acc. to DIN 1944)<br />
at<br />
delivery height (bar)<br />
(1 bar = 10mWG)<br />
T 6 L<br />
UWP 4-1<br />
660 0<br />
560 0.5<br />
400 1.0<br />
160 1.5<br />
0 1.8<br />
T 8<br />
800 0<br />
690 0.5<br />
500 1.0<br />
210 1.5<br />
0 1.8<br />
T 12<br />
UWP 8-1<br />
1300 0<br />
1150 0.5<br />
870 1.0<br />
440 1.5<br />
0 2.0<br />
T 16<br />
1600 0<br />
1400 0.5<br />
1060 1.0<br />
600 1.5<br />
0 2.1<br />
T 20<br />
UWP 15-1<br />
2200 0<br />
1980 0.5<br />
1520 1.0<br />
850 1.5<br />
0 2.1<br />
Voltage (V) 230 400 400 400 400<br />
Output<br />
kW<br />
P up kW<br />
P down<br />
1.6<br />
1.2<br />
2.0<br />
1.5<br />
Rated current (A) 8.1 3.8 5.5 6.5 9.3<br />
Grain passage (Δ mm) 8 15<br />
20 m H0 7 RN –F.G. 4 x 1.5 mm 2 5 x 1,5 mm 2 5 x 2,5 mm 2<br />
Δ x height x max. proj. 20 x 50 x23 26 x 56 x 39 26 x 57 x 44<br />
Weight w/o cable (kg) 18 19 35 37 39<br />
Weight w/o cable (kg) 24 23 24 42 47<br />
Without Coupling<br />
Order No.<br />
Coupling system Storz<br />
Order No.<br />
Coupling system British<br />
Standard<br />
Order No.<br />
Coupling system NH<br />
Order No.<br />
BSP thread<br />
2 1 /2" male<br />
933000<br />
Storz B<br />
2 1 /2"<br />
933010<br />
BS 336<br />
2 1 /2" female<br />
933013<br />
NH 1 1 /2" male<br />
933012<br />
Recommended Accessories:<br />
933060 Floating switch for T 6 L<br />
Weight: 1,6 kg.<br />
BSP thread<br />
2 1 /2" male<br />
933019<br />
Storz B<br />
2 1 /2"<br />
933020<br />
BS 336<br />
2 1 /2" female<br />
933021<br />
NH 2 1 /2" male<br />
933022<br />
3.0<br />
2.4<br />
BSP thread<br />
2 1 /2" male<br />
933028<br />
Storz B<br />
2 1 /2"<br />
933030<br />
BS 336<br />
2 1 /2" female<br />
933031<br />
NH 2 1 /2" male<br />
933032<br />
933070 Floating switch for T 8, T 12, T 16 and T 20<br />
Weight: 2,8 kg.<br />
3.7<br />
3.0<br />
BSP thread<br />
4" male<br />
93304001<br />
Storz A<br />
4"<br />
933040<br />
connection sockets, our model T 6 L runs on 230 V AC, i.e. is quite happy<br />
with a normal household plug socket. Furthermore, because building sites<br />
and disaster clean-up sites are not always noted for the cleanness of the<br />
water found on them, the pumps have been designed in such a way that<br />
— depending on the model — solids of up to 20 mm diameter will neither<br />
block nor damage the pump. If the pump should run dry for a time, this<br />
does not matter to it either. The particular advantage of this pump lies in<br />
its extremely low weight in comparison with its exceptionally high power.<br />
A novel electronic rotation-direction controller prevents the larger submersible<br />
pumps rotating in the wrong direction. This does away with the need<br />
for checking the direction of rotation and for switching over or reconnecting<br />
the supply lead.<br />
In addition, the electronic system is equipped with temperature sensors for<br />
monitoring the motor.<br />
In the event of a phase failure, under voltage or over temperature, the<br />
electronic system switches off the pump automatically. As soon as the<br />
operating conditions have returned to normal, it automatically switches it<br />
back on again.<br />
5.3<br />
4.5<br />
BSP thread<br />
4" male<br />
93304501<br />
Storz A<br />
4"<br />
933045<br />
933010 933020<br />
933030 933040/933045<br />
delivery hose<br />
Pump with floating switch