04.03.2015 Views

GTO/PRO GP-SW100 - Gate Openers | Access Controls

GTO/PRO GP-SW100 - Gate Openers | Access Controls

GTO/PRO GP-SW100 - Gate Openers | Access Controls

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Control Board Description<br />

COM<br />

+12V<br />

OPEN<br />

COM<br />

COM<br />

+12V<br />

OPEN<br />

COM<br />

COM<br />

+12V<br />

OPEN<br />

COM<br />

2<br />

1<br />

ALARM<br />

EXIT SHADOW SAFETY<br />

<strong>GTO</strong> LOOP DETECTORS<br />

LIMIT SENSORS<br />

BLDC SPEED CONTROL<br />

3<br />

STATUS<br />

4<br />

5<br />

+12Vdc<br />

COM<br />

DUAL LINK<br />

LINK COM<br />

ACC. POWER DUAL CABLE<br />

+ ACC. PWR.<br />

12VDC<br />

- 300ma<br />

DUAL<br />

LINK<br />

AT OPEN<br />

LIMIT<br />

PRISON<br />

MODE<br />

LOCK N.C.<br />

14<br />

LOCK<br />

13<br />

20<br />

6<br />

LOCK COM<br />

7<br />

8<br />

9<br />

LOCK N.O.<br />

RUN 1<br />

RUN 2<br />

CLOSED 1<br />

CLOSED 2<br />

CYCLE<br />

SAFETY<br />

SHADOW<br />

LOOP<br />

OPEN EDGE<br />

CLOSE EDGE<br />

OPEN<br />

CLOSE<br />

STOP<br />

RELAY OUTPUTS<br />

RUNNING<br />

CLOSED<br />

12<br />

11<br />

CYCLE<br />

SAFETY<br />

SHADOW<br />

OPEN<br />

EDGE<br />

CLOSE<br />

EDGE<br />

OPEN<br />

CLOSE<br />

STOP<br />

10<br />

OFF<br />

OFF<br />

<br />

ON<br />

ON<br />

>>><br />

SIMUL<br />

SLAVE<br />

SECURE<br />

DIAG.<br />

PORT<br />

OPTIONS<br />

MODE 1<br />

MODE 2<br />

OPEN DIR.<br />

SLV OPN<br />

DUAL MODE<br />

LOW BATT<br />

AUTO CLOSE<br />

TIMER<br />

18<br />

MIN MAX MIN MAX OFF 120<br />

16<br />

SET<br />

LIMIT<br />

COM<br />

COM<br />

COM<br />

COM<br />

COM<br />

COM<br />

W1<br />

CUT TO USE<br />

3 BUTTON<br />

STATION<br />

21<br />

<strong>GTO</strong> Inc. Tallahassee, FL<br />

SX4000 Logic Board Rev. E<br />

TEST SWITCHES<br />

CLOSE 15 STOP OPEN<br />

1<br />

BLDC Motor Control Connection<br />

12<br />

LED Indicator - To Show ‘Running’ Relay is on<br />

2<br />

Limit Sensor Connection<br />

13<br />

LED Indicator - To Show ‘Lock’ Relay is on<br />

3<br />

Alarm / Buzzer Connection<br />

14<br />

LED Indicators - To Show Dual Link Communication<br />

4<br />

12Vdc <strong>Access</strong>ory Power<br />

15<br />

Test Switches - To Control <strong>Gate</strong> Operation<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

11<br />

Dual Link Connection<br />

Relay Output - To Control Lock<br />

Relay Output - To Indicate <strong>Gate</strong>’s Running<br />

Relay Output - To Indicate <strong>Gate</strong>’s Closed<br />

<strong>Access</strong>ory Inputs<br />

LED Indicators - For accessory inputs<br />

LED Indicators - To show ‘closed’ relay is on<br />

16<br />

17<br />

18<br />

19<br />

20<br />

21<br />

Limit Adjustment Control Switches<br />

Left and Right Stall Force Adjustment<br />

Auto Close Timers Adjustment Potentiometer (OFF, 3-120 sec)<br />

DIP Switch Option Setting<br />

Diagnostic Port (NOT for telephone)<br />

W1- for 3-button Station with Normally Close ‘Stop’ Button<br />

16

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!