Control Board Description<br />
COM<br />
+12V<br />
OPEN<br />
COM<br />
COM<br />
+12V<br />
OPEN<br />
COM<br />
COM<br />
+12V<br />
OPEN<br />
COM<br />
2<br />
1<br />
ALARM<br />
EXIT SHADOW SAFETY<br />
<strong>GTO</strong> LOOP DETECTORS<br />
LIMIT SENSORS<br />
BLDC SPEED CONTROL<br />
3<br />
STATUS<br />
4<br />
5<br />
+12Vdc<br />
COM<br />
DUAL LINK<br />
LINK COM<br />
ACC. POWER DUAL CABLE<br />
+ ACC. PWR.<br />
12VDC<br />
- 300ma<br />
DUAL<br />
LINK<br />
AT OPEN<br />
LIMIT<br />
PRISON<br />
MODE<br />
LOCK N.C.<br />
14<br />
LOCK<br />
13<br />
20<br />
6<br />
LOCK COM<br />
7<br />
8<br />
9<br />
LOCK N.O.<br />
RUN 1<br />
RUN 2<br />
CLOSED 1<br />
CLOSED 2<br />
CYCLE<br />
SAFETY<br />
SHADOW<br />
LOOP<br />
OPEN EDGE<br />
CLOSE EDGE<br />
OPEN<br />
CLOSE<br />
STOP<br />
RELAY OUTPUTS<br />
RUNNING<br />
CLOSED<br />
12<br />
11<br />
CYCLE<br />
SAFETY<br />
SHADOW<br />
OPEN<br />
EDGE<br />
CLOSE<br />
EDGE<br />
OPEN<br />
CLOSE<br />
STOP<br />
10<br />
OFF<br />
OFF<br />
<br />
ON<br />
ON<br />
>>><br />
SIMUL<br />
SLAVE<br />
SECURE<br />
DIAG.<br />
PORT<br />
OPTIONS<br />
MODE 1<br />
MODE 2<br />
OPEN DIR.<br />
SLV OPN<br />
DUAL MODE<br />
LOW BATT<br />
AUTO CLOSE<br />
TIMER<br />
18<br />
MIN MAX MIN MAX OFF 120<br />
16<br />
SET<br />
LIMIT<br />
COM<br />
COM<br />
COM<br />
COM<br />
COM<br />
COM<br />
W1<br />
CUT TO USE<br />
3 BUTTON<br />
STATION<br />
21<br />
<strong>GTO</strong> Inc. Tallahassee, FL<br />
SX4000 Logic Board Rev. E<br />
TEST SWITCHES<br />
CLOSE 15 STOP OPEN<br />
1<br />
BLDC Motor Control Connection<br />
12<br />
LED Indicator - To Show ‘Running’ Relay is on<br />
2<br />
Limit Sensor Connection<br />
13<br />
LED Indicator - To Show ‘Lock’ Relay is on<br />
3<br />
Alarm / Buzzer Connection<br />
14<br />
LED Indicators - To Show Dual Link Communication<br />
4<br />
12Vdc <strong>Access</strong>ory Power<br />
15<br />
Test Switches - To Control <strong>Gate</strong> Operation<br />
5<br />
6<br />
7<br />
8<br />
9<br />
10<br />
11<br />
Dual Link Connection<br />
Relay Output - To Control Lock<br />
Relay Output - To Indicate <strong>Gate</strong>’s Running<br />
Relay Output - To Indicate <strong>Gate</strong>’s Closed<br />
<strong>Access</strong>ory Inputs<br />
LED Indicators - For accessory inputs<br />
LED Indicators - To show ‘closed’ relay is on<br />
16<br />
17<br />
18<br />
19<br />
20<br />
21<br />
Limit Adjustment Control Switches<br />
Left and Right Stall Force Adjustment<br />
Auto Close Timers Adjustment Potentiometer (OFF, 3-120 sec)<br />
DIP Switch Option Setting<br />
Diagnostic Port (NOT for telephone)<br />
W1- for 3-button Station with Normally Close ‘Stop’ Button<br />
16