Overview of a Dual <strong>Gate</strong> Operator Installation<br />

The diagram below is an example of a dual swing gate installation with required safety features. The operators must be installed on the inside of<br />

the gate. You must install safety edges and photo beams (not included) to reduce the possibility of bodily injury.<br />

Slave Operator<br />

Master Operator<br />

Safety Edge<br />

Warning Sign<br />

Safety Edges<br />

Warning Sign<br />

Safety Edge<br />

Receiver<br />

RB709U<br />

(NOT INCLUDED)<br />

Operator<br />

Operator<br />

Operator<br />

Use Rigid Conduit<br />

for inbound AC.<br />

Safety Edge<br />

Photo Beams<br />

R4222<br />

(NOT INCLUDED)<br />

Dual <strong>Gate</strong> Interface<br />

Run Belden Wire® ONLY in its<br />

own conduit, 22 AWG ,<br />

1-pair shielded with GROUND.<br />

OPTIONAL<br />

Closed Position<br />

Positive Stop Plates<br />

Safety Edge<br />

OPTIONAL Closed Position<br />

Ground Stop Post and Plate<br />

Photo Beams<br />

R4222<br />

(NOT INCLUDED)<br />

Use PVC Conduit<br />

for Receiver<br />

Use Rigid Conduit<br />

for inbound AC.<br />

NOTE: A separate gate or entrance must be installed for pedestrian use. Not shown here.<br />