10 Jointing of precast products<br />

(including pipes) lined with Plastiline to<br />

insitu structures<br />

10.1 Where a product lined with Plastiline is to be joined<br />

to an unlined insitu structure a liner return shall be made as<br />

follows:<br />

The lining is cut off flush with the end of the product and<br />

an end cap is fabricated to cover the end, and form a<br />

50mm (minimum) return on the outside surface.<br />

The end cap is not keyed to the product and plain PVC<br />

sheet is used. The annular shape to cover the end may be<br />

formed from several pieces butted together with a gap less<br />

than 4mm, and may be held in place by an approved<br />

adhesive for welding. Outside corner weld strip is used to<br />

join the annular shape to the lining and to the return. Any<br />

butt joints are sealed with flat welding strip.<br />

10.2 Where a product lined with Plastiline joins a lined<br />

insitu structure the joint shall be constructed by one of the<br />

following methods:<br />

a) Where the product is to be connected after the<br />

insitu structure has been constructed, a hole should be cut<br />

or formed in the structure and the joint made using an<br />

approved method.<br />

The joint protection is then provided by using a piece of<br />

plain sheet with a central hole cut to fit the interior of the<br />

product. This also overlaps the surrounding insitu lining by<br />

50mm (minimum) to 200mm (maximum). The plain sheet<br />

may be made up from several pieces. It is welded to the<br />

product lining using outside corner welding strip and to the<br />

insitu lining using flat welding strip.<br />

b) If the end of the product is to be cast into the insitu<br />

structure the keys on the lining fitted to the inside<br />

formwork should be cut off at the joint position and the<br />

lining trimmed off flush with the end of the product, which<br />

is then placed in position and held against the insitu lining<br />

during the pouring of the structure. After removal of the<br />

formwork the insitu lining is cut away flush with the<br />

interior of the product and welded to the precast product<br />

lining using outside corner strip.<br />

10.3 All field welds, and any repairs carried out in the field<br />

shall be subject to the inspection and testing<br />

specified in Clause 11.<br />

Precast access chamber base with benching.<br />