Installation<br />
AC Terminal Block<br />
(AC input and output wiring)<br />
<strong>MS</strong>2012-15B or<br />
<strong>MS</strong>2012-20B Inverter<br />
AC NEUT OUT<br />
(x2 )<br />
AC HOT 2 OUT<br />
AC HOT 1 OUT<br />
AC HOT 2 IN<br />
( from M a in P a nel)<br />
AC HOT 1 IN<br />
(from Main Panel)<br />
AC NEUT IN<br />
(from Main Panel)<br />
AC GROUNDS<br />
(to/from both<br />
Panels)<br />
SINGLE IN / DUAL OUT wiring<br />
In Mobile installations : neutral is typically not<br />
connected to ground In main panel.<br />
ON<br />
OFF<br />
120<br />
VAC<br />
120<br />
VAC<br />
Direct from inverter<br />
(Inverter Loads)<br />
OF F<br />
ON<br />
ON<br />
30<br />
OF F<br />
OFF OF F OFF OF F OFF<br />
ON ON ON ON ON<br />
ON ON ON ON ON<br />
OF F OFF OFF OF F OFF<br />
Maximum breaker size<br />
required to inverter AC input<br />
depends on model used.<br />
<strong>MS</strong>2012-15B: 30 amp<br />
breaker (single pole);<br />
<strong>MS</strong>2012-20B: 40amp<br />
breaker (single pole).<br />
Main Panel<br />
(U tility /Generator Input)<br />
Figure 2-13, AC Wiring for Single In - Dual Out Configurations<br />
© 2009 <strong>Magnum</strong> <strong>Energy</strong> Inc.<br />
Page 27