16.03.2015 Views

MS Series Owner's Manual - Magnum Energy

MS Series Owner's Manual - Magnum Energy

MS Series Owner's Manual - Magnum Energy

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Appendix A - Specifications<br />

Appendix A - Specifications and Optional Equipment<br />

A-1 Inverter/Charger Specifications<br />

<strong>MS</strong>2012 (-15B, -20B) <strong>MS</strong>2812 <strong>MS</strong>4024<br />

Inverter Specifications<br />

Input battery voltage range 9.0 to 16.8 VDC 9.0 to 16.8 VDC 18.0 to 33.6 VDC<br />

Absolute maximum DC input 25 VDC 25 VDC 35 VDC<br />

AC output voltage accuracy<br />

120 VAC ±5% (≤ continuous power)<br />

Output frequency and accuracy<br />

60 Hz ± 0.1 Hz<br />

Total Harmonic Distortion (THD) < 5%<br />

Continuous power output (at 25° C) 2000 VA 2800 VA 4000 VA<br />

Continuous AC output current 17 A 23 A 33 A<br />

1 msec surge current (amps AC) 50 70 120<br />

100 msec surge current (amps AC) 33 40 82<br />

5 sec surge power (real watts) 3300 3900 5800<br />

30 sec surge power (real watts) 3100 3800 5400<br />

5 min surge power (real watts) 2800 3200 4900<br />

30 min surge power (real watts) 2200 3000 4500<br />

Maximum continuous input current 222 ADC 311 ADC 222 ADC<br />

Inverter efficiency (peak) 90.6% 90% 93.7%<br />

HBCO/HBCI (High Battery Cut Out/In) 16.8 VDC/16.5 VDC 16.8 VDC/16.5 VDC 33.6 VDC/33.0 VDC<br />

LBCO/LBCI (Low Battery Cut Out/In) 9.0 VDC (adj)/12.5 VDC 9.0 VDC (adj)/12.5 VDC 18.0 VDC (adj)/25.0 VDC<br />

<strong>Series</strong> Stacking for 120/240 VAC No No Yes, using two <strong>MS</strong>4024 units<br />

AC Relay Transfer time (minimum)<br />

16 msec<br />

Power Consumption - searching<br />

0.95<br />

General Features and Capabilities<br />

Transfer relay capability<br />

30 AAC maximum each input (60 AAC total)*<br />

Five-stage charging capability<br />

Bulk, Absorb, Float, Equalize (requires remote), and Battery Saver<br />

Battery temperature compensation<br />

Standard with available temp sensor connected (battery temp 0 - 50 °C)<br />

Internal Cooling<br />

0 to 120 cfm variable speed drive using dual 92 mm brushless DC fan<br />

Overcurrent protection<br />

with two overlapping circuits<br />

Overtemperature Protection<br />

on transformer, MOSFETS, and temperature<br />

Corrosion protection<br />

PCB’s conformal coated, powder coated chassis/top, and stainless steel fasteners<br />

Safety Listings ETL listed to UL/cUL STD 458, UL STD 1741 and CSA STD C22.2 No. 107.1-01<br />

Warranty<br />

3 years parts and labor<br />

Branch rated output circuit breakers<br />

only on <strong>MS</strong>2012 -15B (15A x2) and <strong>MS</strong>2012-20B (20A x2) models.<br />

Environmental Specifications<br />

Operating temperature<br />

-20°C to +60°C (-4°F to 140°F)<br />

Non-Operating temperature<br />

-40°C to +70°C (-40°F to 158°F)<br />

Operating humidity<br />

0 to 95% RH non-condensing<br />

Physical Specifications<br />

Unit Dimensions (h x w x d)<br />

13.75” x 12.65” x 8.0” (34.9 cm x 32.1 cm x 20.3 cm)<br />

Shipping Dimensions (h x w x d)<br />

18.5” x 17.5” x 12.5” (47 cm x 44.5 cm x 31.8 cm)<br />

Mounting<br />

Shelf or wall (vents not allowed to face downward unless ME-CB is installed)<br />

Unit Weight 43 lb (19.5 kg) 53 lb (24.0 kg) 58 lb (26.3 kg)<br />

Shipping Weight 46 lb (20.9 kg) 56 lb (25.4 kg) 60 lb (27.2 kg)<br />

Max operating altitude 15,000’ (4570 m)<br />

* pass-thru on -15B and -20B models limited by output breakers<br />

Specifications @ 25°C - Subject to change without notice.<br />

© 2009 <strong>Magnum</strong> <strong>Energy</strong> Inc.<br />