xEnergy –<br />

in the divide of panel building<br />

<strong>Moeller</strong>'s Kit <strong>system</strong> <strong>for</strong> the panel builder is a single-source development that has been designed<br />

<strong>and</strong> thought through to meet the needs of the panel builder. xEnergy offers outst<strong>and</strong>ing<br />

efficiency, flexibility <strong>and</strong> st<strong>and</strong>s out with its simplicity <strong>and</strong> functionality.<br />

Technical <strong>system</strong> features<br />

St<strong>and</strong>ards DIN EN 60439-1 (VDE 0660 Part 500)<br />

Type testing TTA<br />

Internal separation Form 1 to Form 4<br />

Rated operational voltage Ue 690V / 50Hz ... 60 Hz<br />

Rated operational current Ie to 4 000 A<br />

Rated short-time withst<strong>and</strong> resistance Icw bis 100 kA (Effektivwert), 1 s<br />

Ambient temperature 35 °C (40 °C) to 45 °C (50 °C)<br />

Degree of protection IP31/IP55<br />

Network <strong>system</strong> TN-C / TN-C-S / TN-S / IT<br />

Colour RAL 7035 (other colours on request)<br />

Dimensions h 2 000 mm basic height without plinth,<br />

w 425/600/800/1 000/1 200 mm,<br />

d 400/600/800 mm<br />

xEnergy – technical data<br />

Mounting of <strong>Moeller</strong> IZM <strong>and</strong> NZM circuit-breakers up to 4000 A - application benefits:<br />

• Clear <strong>and</strong> symmetrical design with only one circuit-breaker per section<br />

reduces the number of busbar connections <strong>and</strong> saves mounting requirements,<br />

• Internal separation up to Form 4 increases personnel <strong>and</strong> <strong>system</strong> protection,<br />

• Circuit-breaker mounting kits <strong>for</strong> optimum assembly <strong>and</strong> packed as a unit,<br />

• Fast <strong>and</strong> direct allocation of mounting kits <strong>for</strong> the mechanical fastening of circuitbreakers,<br />

• High level of flexibility in the terminal area thanks to alternative connection options: Cable<br />

terminal <strong>system</strong>, straps or busbar adapters.<br />

Mounting of <strong>Moeller</strong> switching <strong>and</strong> protective devices up to 630 A - application benefits:<br />

• Max. 38 fixed compartment modules in one section (h = 50 mm), to 40 A<br />

• Max. 19 fixed compartment modules in one section (h = 100 mm), to 160 A<br />

• Optimum device utilisation despite high packing density<br />

• Simple module mounting to Form 2 on one mounting depth,<br />

• Flexible module mounting to Form 4 with different device mounting depths, with st<strong>and</strong>ard<br />

operating front,<br />

• Highly flexible combination possible <strong>for</strong> functional areas <strong>and</strong> busbars in accordance with<br />

EN 60439 (VDE 0660 Part 500) <strong>and</strong> national installation practice.<br />

xEnergy – the new <strong>system</strong> offer in panel building – application benefits of the optimised<br />

<strong>system</strong> plat<strong>for</strong>m up to 4 000 A:<br />

• Low number of individual parts <strong>and</strong> modules,<br />

• Suitable <strong>for</strong> universal use (DIN VDE, IEC, NF [France], UNE [Spain]),<br />

• Can be combined flexibly,<br />

• Low earth transition resistance <strong>for</strong> personnel protection,<br />

• Efficient selection <strong>and</strong> configuration using <strong>Moeller</strong> ConFix<br />

• Functionally packed into individual assemblies, supplied as flat pack<br />

• Easy <strong>and</strong> fast to install – 30 minutes per section,<br />

• Fully type-tested <strong>and</strong> designed <strong>for</strong> <strong>future</strong> requirements.<br />

accordance with binding documents<br />

<strong>and</strong> supplier specifications.<br />

The construction of partially type-tested<br />

assemblies (PTTA) involves the use<br />

of both type-tested <strong>and</strong> non type-tested<br />

functional assemblies. Test certificates<br />

• Heft 7/2004<br />

are equally required <strong>for</strong> PTTAs. These<br />

can be provided by means of additional<br />

type testing or by the derivation of<br />

similar <strong>system</strong>s from type-tested<br />

assemblies. Additional calculations are<br />

also required depending on the type of<br />

PTTA involved: Short-circuit (DIN IEC<br />

1117 (VDE 0660 Part 509):1993-09 [7, 8])<br />

<strong>and</strong> temperature rise (IEC/TR 60890).<br />

1987-07 [9]).<br />

Future-<strong>proof</strong> switchboard <strong>system</strong> –<br />

the plat<strong>for</strong>m <strong>for</strong> results-based<br />

solutions<br />

The project business is defining <strong>and</strong><br />

shaping the market <strong>for</strong> low-voltage<br />

switchboard <strong>system</strong>s. End customers<br />

require individual solutions <strong>for</strong> their<br />

specific requirements with an optimum<br />

price-per<strong>for</strong>mance ratio. This kind of<br />

financially flexible solution can only be<br />

offered by a modular <strong>power</strong> <strong>distribution</strong><br />

<strong>system</strong> that is based on an intelligent<br />

plat<strong>for</strong>m concept. The divide between<br />

ever increasing dem<strong>and</strong>s in terms of<br />

engineering <strong>and</strong> <strong>safe</strong>ty on the one h<strong>and</strong>,<br />

<strong>and</strong> cost reduction on the other can<br />

only be bridged by means of an innovative<br />

generation of switchboard <strong>system</strong>s<br />

(Picture 1).<br />

xEnergy – the new <strong>power</strong><br />

<strong>distribution</strong> <strong>system</strong> generation<br />

xEnergy, <strong>Moeller</strong>'s new integrated <strong>system</strong><br />

range, st<strong>and</strong>s <strong>for</strong> <strong>power</strong> <strong>distribution</strong><br />

<strong>system</strong>s that are specially designed <strong>for</strong><br />

the building infrastructure up to 4 000 A.<br />

<strong>Moeller</strong> are single-source suppliers of an<br />

intelligent <strong>system</strong> plat<strong>for</strong>m <strong>for</strong> switching<br />

<strong>and</strong> protective devices that panel builders<br />

can customise, assemble quickly <strong>and</strong><br />

h<strong>and</strong>le easily. Based on many years of<br />

practical experience in the building of<br />

switchgear assemblies, <strong>Moeller</strong> has developed<br />

the latest generation of switchboard<br />

<strong>system</strong>s that incorporates the latest trends<br />

<strong>and</strong> essential features. The individual switching<br />

<strong>and</strong> protective devices, the associated<br />

mounting <strong>system</strong> design <strong>and</strong> also<br />

the switchgear are combined to <strong>for</strong>m one<br />

technical unit. This kind of <strong>system</strong> is both<br />

economical <strong>and</strong> reliable at the same time,<br />

as perfectly matched <strong>and</strong> type-tested functional<br />

units have been developed as a<br />

modular <strong>system</strong>. Exactly tailored function<br />

modules that have been type-tested in<br />

accordance with DIN EN 60439-1 (VDE<br />

0660 Part 500), <strong>and</strong> available with internal<br />

separation from Form 1 to Form 4, comply<br />

with national installation requirements<br />

(DIN VDE, IEC, NF [France], UNE [Spain])<br />

(Picture 2). The <strong>system</strong> range consists of:<br />

• Feeder <strong>and</strong> coupling sections <strong>for</strong> circuit-breakers<br />

up to 4 000 A,<br />

• Individually equipped outgoer sections<br />

with fixed compartment modules <strong>for</strong><br />

switching <strong>and</strong> protective devices in-<br />

3

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!