Download 2009 Product summary - BEKA Associates
Download 2009 Product summary - BEKA Associates
Download 2009 Product summary - BEKA Associates
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
product<br />
<strong>summary</strong><br />
<strong>2009</strong><br />
Display<br />
instrumentation<br />
for use in safe and<br />
hazardous areas<br />
visit our website www.beka.co.uk
4/20mA Loop powered<br />
digital indicators<br />
The most extensive range of 4/20mA loop powered indicators<br />
available; includes models for all applications backed by 25 years<br />
of continuous development and a three year no quibble<br />
guarantee.<br />
Intrinsically safe<br />
Type nL<br />
Flameproof<br />
General purpose<br />
◆ Intrinsically safe ATEX, FM,<br />
cFM & IECEx certified, Type nL<br />
and general purpose models<br />
◆ Loop powered only 1V drop<br />
◆ Robust IP66 field mounting<br />
instruments with separate<br />
terminal compartments<br />
◆ Panel mounting models with<br />
IP65 fronts<br />
◆ 3 1 /2 and 4 1 /2 digit displays<br />
◆ Optional:<br />
separately powered backlight<br />
loop powered backlight<br />
dual alarms<br />
calibrator ⊕<br />
root extraction ⊕<br />
16 point linearisation<br />
tare function<br />
⊕ standard on 4 1 /2 digit models<br />
◆ Flameproof models in<br />
aluminium & stainless steel<br />
enclosures now available.<br />
Maximum display for 3 1 /2 digit<br />
indicators<br />
Maximum display for 4 1 /2 digit<br />
indicators<br />
No backlight<br />
Display readable in daylight<br />
Hazardous area<br />
TAG NUMBER<br />
SCALE<br />
Safe area<br />
Loop powered backlight<br />
Display readable in poor lighting<br />
conditions<br />
2-wire<br />
Tx<br />
4/20mA<br />
Zener barriers or<br />
galvanic isolators<br />
4/20mA<br />
circuit<br />
Separately powered backlight<br />
Display contrast enhanced in all<br />
lighting conditions<br />
Recently introduced<br />
Ex d MODELS<br />
To obtain more information<br />
about any of the products<br />
shown in this <strong>summary</strong>, please<br />
visit our web site at<br />
www.beka.co.uk or request a<br />
copy of our full catalogue from<br />
our sales office or any of our<br />
overseas agents.
Mounting Display Display Certification<br />
height Europe ATEX USA FM & Canada cFM International IECEx<br />
Intrinsically safe – for use in gas and dust hazardous areas<br />
BA304D Field 3 1 /2 digits 25mm Group II<br />
BA324D Field 4 1 /2 digits 20mm<br />
IS/I,II,III/1/ABCDEFG Ex ia IIC T5<br />
Category 1GD*<br />
NI/I,II,III/2/ABCDEFG DIP A21 TA 80˚C IP66*<br />
EEx ia IIC T5<br />
BA307C Panel 3 1 /2 digits 13mm<br />
BA308C Panel 3 1 /2 digits 25mm Group II<br />
IS/I/1/ABCD<br />
BA327C Panel 4 1 /2 digits 10mm Category 1G<br />
NI/I/2/ABCD<br />
BA328C Panel 4 1 /2 digits 20mm EEx ia IIC T5<br />
Ex ia IIC T5<br />
BA326C Panel 4 1 /2 digits plus fast bargraph Group II IS/I/1/ABCD Ex ia IIC T5<br />
Category 1G NI/I/2/ABCD<br />
EEx ia IIC T5 (US only)<br />
Type nL – for use in Zone 2 gas and dust hazardous areas<br />
BA304ND Field 3 1 /2 digits 25mm Group II – –<br />
BA324ND Field 4 1 /2 digits 20mm Category 3GD*<br />
*ATEX and IECEx dust certification is an option<br />
EEx nL IIC T5<br />
Flameproof<br />
USA FM and Canada CSA<br />
BR323 Field 5 digits 10mm EEx d IIC T6 Ex d/1/ABCDEFG –<br />
General purpose<br />
BA504D Field 3 1 /2 digits 25mm<br />
BA524D Field 4 1 /2 digits 20mm<br />
BA507C Panel 3 1 /2 digits 13mm<br />
BA508C Panel 3 1 /2 digits 25mm<br />
BA527C Panel 4 1 /2 digits 10mm<br />
BA528C Panel 4 1 /2 digits 20mm<br />
BA526C Panel 4 1 /2 digits plus fast bargraph<br />
Set point<br />
stations<br />
Ideal for adjusting process set points<br />
from within a safe or hazardous<br />
process area, these loop powered<br />
instruments incorporate a 3 1 /2 digit<br />
display to show the 4/20mA current<br />
in engineering units.<br />
◆ ATEX & FM intrinsically safe and<br />
general purpose models<br />
◆ Easy to read display with<br />
optional:<br />
loop powered backlight<br />
or separately powered backlight<br />
◆ IP65 front panel<br />
Indicating<br />
temperature<br />
transmitters<br />
Hazardous area<br />
Certification<br />
Europe ATEX<br />
USA FM<br />
Intrinsically safe – for use in all gas hazardous areas<br />
BA405C-IND Group II Cat 1G EEx ia IIC T5 IS/I/1/ABCD<br />
NI/I/2/ABCD<br />
General purpose<br />
BA505C-IND –<br />
4/20mA<br />
Safe area<br />
Zener barriers or<br />
galvanic isolators<br />
4/20mA<br />
circuit<br />
Effectively combining a 4/20mA loop powered temperature transmitter plus a loop<br />
powered indicator, these instruments accurately display temperature on a large easy to<br />
read display and transmit an accurate, linear 4/20mA current proportional to<br />
temperature. Designed for use in all hazardous areas, this range of indicating<br />
temperature transmitters can be conditioned on-site to operate with most types of<br />
resistance thermometer and thermocouple.<br />
◆ ATEX intrinsically safe, Type nL and general purpose models<br />
◆ Loop powered - 4/20mA output<br />
◆ Bold 20mm high easy to read display<br />
◆ Temperature display in ˚C or ˚F<br />
◆ Optional alarms and display backlighting<br />
Intrinsically safe models - for use in all gas hazardous areas<br />
BA374C Field mounting, GRP or aluminium IP66 enclosure,<br />
ATEX Group II Category 1G EEx ia IIC T5<br />
BA378C Panel mounting, IP65 front ATEX Group II Category 1G EEx ia IIC T5<br />
Type nL model - for use in Zone 2 hazardous areas<br />
BA374NC Field mounting, GRP or aluminium, IP66 enclosure, ATEX Group II Category 3G
Serial text<br />
displays<br />
NOW WITH MODBUS<br />
Low cost operator interfaces that are<br />
ideal for simple machine and process<br />
control applications in hazardous and<br />
safe areas. Field mounting instruments<br />
have a robust IP66 GRP<br />
enclosure with a separate terminal<br />
compartment; the panel mounting<br />
models have IP66 sealed fronts.<br />
◆ High contrast display with backlight,<br />
operator pushbuttons and<br />
two switch outputs<br />
◆ Selectable Modbus, <strong>BEKA</strong> or<br />
Legacy protocol<br />
◆ Displays up to four variables on<br />
one of nine standard screen<br />
formats, some with bargraphs<br />
◆ ATEX, FM, cFM & IECEx certified<br />
intrinsically safe models communicate<br />
via a <strong>BEKA</strong> BA201 galvanic<br />
isolator which has RS232<br />
and RS485 safe area ports, or<br />
equivalent isolators may be used<br />
◆ General purpose models have<br />
RS232 or RS485 ports<br />
◆ Powerful pattern matching facility<br />
enables data in proprietary<br />
ASCII strings to be displayed<br />
◆ Free <strong>BEKA</strong> ScreenWriter software<br />
simplifies design of custom<br />
screen formats<br />
◆ Robust IP66 field mounting and<br />
IP66 panel mounting models<br />
FREE simulation and<br />
ScreenWriter software<br />
Operator<br />
Certification<br />
Mounting Push buttons Outputs Communication Europe ATEX USA FM & Canada cFM International IECEx<br />
Intrinsically safe – for use in all gas and dust hazardous areas<br />
IS/I,II,III/1/<br />
BA484D Field 4 2 Via BA201. Other Group II ABCDEFG EEx ia IIC T5<br />
galvanic isolators Category 1GD* NI/I,II,III/2/ EEx iaD 20 T80*<br />
may be used EEx ia IIC T5 ABCDEF<br />
Via BA201. Other Group II IS/I/1/ABCD<br />
BA488C Panel 6 2 galvanic isolators Category 1G NI/I/2/ABCD EEx ib IIC T5<br />
may be used EEx ia IIC T5<br />
General purpose<br />
BA684D Field 4 2 RS232 or<br />
RS485<br />
BA688C Panel 6 2 RS232 or<br />
RS485<br />
*ATEX & IECEx dust certification is an option<br />
Hazardous area<br />
S1 S2 S3 S4 S5 S6 S7<br />
S1 S2 S3 S4 S5 S6 S7<br />
BA488C<br />
1200<br />
820 kg<br />
0<br />
Optional external switches<br />
6<br />
5<br />
4<br />
3<br />
2<br />
1<br />
6<br />
5<br />
4<br />
3<br />
2<br />
1<br />
Safe area<br />
Recently introduced<br />
BA201<br />
Communications isolator<br />
RS232<br />
or<br />
RS485<br />
+ 20 to 35V dc<br />
To simplify hazardous area installations, the new dedicated BA201 galvanic isolator can power and communicate with up to four<br />
BA484D and BA488C serial text displays.<br />
Mounting Location Safe area No. of text displays Europe ATEX USA FM & International<br />
communication in hazardous area Canada cFM IECEx<br />
Intrinsically safe output – for use in all gas and dust hazardous areas<br />
BA201 DIN rail Safe area RS232 & 2 with 2-wire system IS circuit Group 2 IS circuit IS circuit<br />
RS485 4 with 3-wire system [Ex ia] IIC IS/I/1/ABCDEFG [Ex ia] IIC
Fieldbus<br />
indicators<br />
& displays<br />
An extensive range of robust, bus<br />
powered, single variable fieldbus<br />
indicators and eight variable fieldbus<br />
displays featuring large easy to read<br />
displays. Includes ATEX, FM, cFM and<br />
IECEx certified intrinsically safe, Type<br />
nL and nonincendive models plus<br />
general purpose instruments.<br />
FIELDBUS INDICATORS<br />
FISCO & FNICO compliant<br />
◆ Single FOUNDATION fieldbus TM variable<br />
Hazardous area<br />
Safe area<br />
◆ 5 digit 20mm high display with 31 segment bargraph<br />
BA488CF<br />
FIELDBUS DISPLAYS<br />
◆ Up to 8 FOUNDATION fieldbus TM or Profibus PA variables<br />
1 2<br />
◆ Choice of 9 standard display screen formats<br />
or custom screens<br />
◆ Backlight<br />
FISCO<br />
Terminator<br />
Fieldbus<br />
FISCO<br />
Terminator<br />
FISCO<br />
Power<br />
Supply &<br />
Segment<br />
Coupler<br />
Host<br />
◆ Operator push buttons and 6 optional outputs<br />
FISCO<br />
Field<br />
Device<br />
FISCO<br />
Field<br />
Device<br />
Certification<br />
Mounting Display Operator Outputs Protocol Europe ATEX USA FM & International<br />
Push buttons Canada cFM IECEx<br />
Intrinsically safe – for use in all gas and dust hazardous areas<br />
BA414DF Field 1 variable 0 0 FF Group II IS/I,II,III/1/ Ex ia IIC T4<br />
5 digits plus Category 1GD* ABCDEFG Ex ia IIC T4 DIP<br />
bargraph EEx ia IIC T4 NI/I,II,III/2/ A21 TA 100 o C IP66*<br />
ABCDEFG<br />
BA418CF Panel 1 variable 0 0 FF Group II IS/I/1/ABCD Ex ia IIC T4<br />
5 digits plus Category 1G NI/I/2/ABCD<br />
bargraph<br />
EEx ia IIC T4<br />
BA484DF Field 8 variables 4 6 FF Group II IS/I,II,III/1 Ex ia IIC T4<br />
120x64 pixel optional or Category 1GD* ABCDEFG Ex ia IIC T4 DIP<br />
with backlight Profibus PA EEx ia IIC T4 NI/I,II,III/2/ A21 TA 125 o C IP66*<br />
ABCDEFG<br />
(US only)<br />
BA488CF Panel 8 variables 6 6 FF Group II IS/I/1/ABCD Ex ia IIC T4<br />
120x64 pixel optional or Category 1G NI/I/2/ABCD<br />
with backlight Profibus PA EEx ia IIC T4 (US only)<br />
Type nL – for use in Zone 2 gas and dust hazardous areas<br />
BA414NDF Field 1 variable 0 0 FF Group II<br />
5 digits plus Category 3GD* Ex nL IIC T4<br />
bargraph EEx nL IIC T4 DIP A22 TA 100 o C IP66*<br />
General purpose<br />
BA614DF Field 1 variable 0 0 FF<br />
5 digits plus<br />
bargraph<br />
BA618CF Panel 1 variable 0 0 FF<br />
5 digits plus<br />
bargraph<br />
BA684DF Field 8 variables 4 6 FF<br />
120x64 pixel optional or<br />
with backlight<br />
Profibus PA<br />
BA688CF Panel 8 variables 6 6 FF<br />
120x64 pixel optional or<br />
with backlight<br />
Profibus PA<br />
*ATEX & IECEx dust certification is an option
Rate<br />
totalisers<br />
An extensive range of instruments<br />
that will calculate and display rate<br />
and total flow in engineering units<br />
from almost any flowmeter with a<br />
pulse or 4/20mA output.<br />
◆ ATEX & FM Intrinsically safe, Type<br />
nL and general purpose models<br />
◆ IP66 field mounting models and<br />
panel mounting models with IP65<br />
front sealing<br />
◆ Separate rate and total displays<br />
◆ 4/20mA input loop powered<br />
instruments<br />
◆ Externally powered and battery<br />
powered instruments for pulse<br />
inputs<br />
◆ Optional alarms, backlights and<br />
re-transmitted outputs<br />
Hazardous area<br />
TAG NUMBER<br />
Safe area<br />
SCALE<br />
visit<br />
our website<br />
w w w.beka.co. u k<br />
N<br />
Zener barriers or<br />
galvanic isolators<br />
Power<br />
24V<br />
V<br />
S<br />
Certification<br />
Mounting Input Powered Europe ATEX USA FM<br />
Intrinsically safe – for use in all gas and dust hazardous areas<br />
BA334D Field Pulse Externally Group II Cat 1GD* EEx ia IIC T5 IS/I,II,III/1/ABCDEFG<br />
NI/I,II.III/2/ABCDEFG<br />
BA338C Panel Pulse Externally Group II Cat 1G EEx ia IIC T5 IS/I/1/ABCD<br />
NI/I/2/ABCD<br />
BA344D Field Pulse Internal battery Group II Cat 1GD* EEx ia IIC T5 –<br />
BA354D Field 4/20mA Loop Group II Cat 1GD* EEx ia IIC T5 –<br />
BA358C Panel 4/20mA Loop Group II Cat 1G EEx ia IIC T5 –<br />
Type nL for use in Zone 2 gas and dust hazardous areas<br />
BA334ND Field Pulse Externally Group II Cat 3GD* –<br />
BA354ND Field 4/20mA Loop Group II Cat 3GD* –<br />
General Purpose<br />
BA534D Field Pulse Externally<br />
BA538C Panel Pulse Externally<br />
BA544D Field Pulse Internal battery<br />
BA554D Field 4/20mA Loop<br />
BA558C Panel 4/20mA Loop<br />
*ATEX dust certification is an option
Easy to use flow batch controllers for dispensing liquids, solids or components.<br />
◆ ATEX Intrinsically safe and general purpose models<br />
◆ Field and panel mounting models<br />
◆ High contrast graphical display with backlight<br />
◆ Configuration menus may be displayed in English, French or German<br />
◆ All models accept pulse and 4/20mA analogue inputs<br />
◆ Three configurable outputs, plus additional three optional outputs<br />
◆ Provision for remote push-buttons<br />
Flow batch<br />
controllers<br />
Intrinsically safe models - for use in all gas and dust hazardous areas<br />
BA454D Field mounting IP66 enclosure ATEX Group II Category 1GD*<br />
BA458C Panel mounting IP66 front ATEX Group II Category 1G<br />
General purpose<br />
BA654D Field mounting IP66 enclosure<br />
BA658C Panel mounting IP66 front<br />
*ATEX dust certification is an option<br />
Counter, timer,<br />
tachometer &<br />
clock<br />
Hazardous area<br />
TAG NUMBER<br />
SCALE<br />
P E<br />
Safe area<br />
Zener barriers or<br />
galvanic isolators<br />
N<br />
A<br />
Power<br />
24V<br />
S<br />
B<br />
V<br />
Certification<br />
Mounting Europe ATEX USA FM<br />
Intrinsically safe – for use in all gas and dust hazardous areas<br />
BA364D Field Group II Cat 1GD* IS/I,II,III/1/ABCDEFG<br />
NI/I,II.III/2/ABCDEFG<br />
BA368C Panel Group II Cat 1G IS/I/1/ABCD<br />
NI/I/2/ABCD<br />
Type nL for use in Zone 2 gas and dust hazardous areas<br />
BA364ND Field Group II Cat 3GD* –<br />
*ATEX dust certification is an option<br />
IS battery powered clock<br />
Intrinsically safe battery powered clock for use in all gas hazardous areas,<br />
featuring a high contrast 25mm display which is easy to read in most lighting<br />
conditions.<br />
◆ Intrinsically safe ATEX certified ◆ Date display<br />
◆ Three year battery life<br />
◆ Selectable automatic correction for<br />
daylight saving<br />
◆ ±1 minute accuracy per year<br />
◆ Can be synchronised to master<br />
◆ 12 or 24 hour display<br />
◆ IP66 front panel<br />
Intrinsically safe model - for use in all gas hazardous areas<br />
BA369 Panel mounting ATEX Group II Category 1G EEx ia IIC T5<br />
A unique collection of ATEX and FM certified instruments which may be conditioned<br />
on-site to perform a wide variety of counting and timing functions. In addition to pulse<br />
counting and time interval measurement or control, the instruments can display<br />
rotational speed and position from quadrature signals or be conditioned to display local<br />
time with alarm outputs.<br />
◆ ATEX & FM intrinsically safe and<br />
Type nL models<br />
◆ Two separate displays<br />
◆ Dual inputs enable instruments to<br />
decode quadrature signals and<br />
to display speed and position<br />
◆ Robust field mounting models in IP66<br />
GRP enclosure with separate terminal<br />
compartment<br />
◆ Panel mounting model with IP65<br />
front<br />
◆ Optional backlight, pulse and<br />
4/20mA outputs
EExd sounders<br />
& beacons<br />
Intrinsically safe<br />
sounder & beacon<br />
Sounder<br />
◆ 32 different sounds<br />
◆ Up to 113dB(A) output<br />
◆ PFEER compliant<br />
◆ IP67 enclosure<br />
Beacon<br />
◆ 5 joule output<br />
◆ Red, amber, yellow, green,<br />
blue or clear lens<br />
◆ IP67 enclosure<br />
Flameproof - ATEX Group II Category 2GD<br />
BExS110D sounder EEx d IIC T4*<br />
BExBG05D beacon<br />
EEx d IIC T6<br />
BExCS110-05D* Combined sounder & beacon<br />
EEx d IIB T4<br />
*ATEX dust certification is an option<br />
LED cluster lamps<br />
High performance intrinsically safe sounder and flashing beacon which<br />
may be used separately or as a pair powered from a single intrinsically<br />
safe circuit.<br />
BR385 Sounder<br />
◆ 49 different sounds<br />
◆ 3 stage alarm<br />
◆ Up to 103dB(A) output<br />
◆ PFEER compliant<br />
◆<br />
◆<br />
IP66 enclosure<br />
Will operate alone or with<br />
BA386 beacon<br />
BA386 Beacon<br />
◆ Red, amber, green, blue &<br />
white models<br />
◆ Two double flashes per<br />
second<br />
◆ Operates alone or with<br />
sounder<br />
◆ Alarm accept function<br />
silences sounder for preset<br />
time.<br />
◆ IP56 enclosure<br />
Intrinsically safe sounders for use in all gas hazardous areas<br />
BR385 ATEX Group II Cat 1G EEx ia IIC T4<br />
FM IS/I/1/ABCD<br />
Intrinsically safe beacon for use in all gas hazardous areas<br />
BA386 ATEX Group II Cat 1G EEx ia IIC T4<br />
FM IS/I/1/ABCD & NI/I/2/ABCD<br />
Panel meters<br />
BA390S operates<br />
at only 4mA<br />
Bright low cost panel mounting lamps with 10 year life<br />
expectancy<br />
◆ ATEX, IECEx & FM intrinsically safe and general purpose<br />
models<br />
◆ Red, Amber, Green, Blue & White versions<br />
◆ BA390 has constant 20mA consumption<br />
◆ BA390S has specified performance at 4mA<br />
Intrinsically safe models<br />
for use in all gas hazardous areas<br />
BA390 20mA ATEX Group II Cat 1G EEx ia IIC T4<br />
BA390S 4mA FM IS/I/1/ABCD NI/I/2/ABCD<br />
IECEx Ga Ex ia IIC T4<br />
<strong>BEKA</strong> associates Ltd<br />
High quality, cost effective general purpose panel meters<br />
featuring high brightness LED displays. Housed in robust metal<br />
enclosures with easy to clean IP65 front panels, models are<br />
available for most process inputs including resistance<br />
thermometers and thermocouples. The single range version can<br />
be supplied conditioned for measuring almost any process<br />
current or voltage.<br />
24Vdc, 115V and 230Vac powered models<br />
General Purpose<br />
A70 Single range process meter<br />
A75 Universal process meter<br />
A80 RTD input temperature meter<br />
A85 THC input temperature meter<br />
Old Charlton Road, Hitchin, Hertfordshire SG5 2DA, England www.beka.co.uk<br />
Telephone +44 (0)1462 438301 Fax +44 (0) 1462 453971 e-mail sales@beka.co.uk<br />
Printed in EU 03-09