product<br />

<strong>summary</strong><br />

<strong>2009</strong><br />

Display<br />

instrumentation<br />

for use in safe and<br />

hazardous areas<br />

visit our website www.beka.co.uk


4/20mA Loop powered<br />

digital indicators<br />

The most extensive range of 4/20mA loop powered indicators<br />

available; includes models for all applications backed by 25 years<br />

of continuous development and a three year no quibble<br />

guarantee.<br />

Intrinsically safe<br />

Type nL<br />

Flameproof<br />

General purpose<br />

◆ Intrinsically safe ATEX, FM,<br />

cFM & IECEx certified, Type nL<br />

and general purpose models<br />

◆ Loop powered only 1V drop<br />

◆ Robust IP66 field mounting<br />

instruments with separate<br />

terminal compartments<br />

◆ Panel mounting models with<br />

IP65 fronts<br />

◆ 3 1 /2 and 4 1 /2 digit displays<br />

◆ Optional:<br />

separately powered backlight<br />

loop powered backlight<br />

dual alarms<br />

calibrator ⊕<br />

root extraction ⊕<br />

16 point linearisation<br />

tare function<br />

⊕ standard on 4 1 /2 digit models<br />

◆ Flameproof models in<br />

aluminium & stainless steel<br />

enclosures now available.<br />

Maximum display for 3 1 /2 digit<br />

indicators<br />

Maximum display for 4 1 /2 digit<br />

indicators<br />

No backlight<br />

Display readable in daylight<br />

Hazardous area<br />

TAG NUMBER<br />

SCALE<br />

Safe area<br />

Loop powered backlight<br />

Display readable in poor lighting<br />

conditions<br />

2-wire<br />

Tx<br />

4/20mA<br />

Zener barriers or<br />

galvanic isolators<br />

4/20mA<br />

circuit<br />

Separately powered backlight<br />

Display contrast enhanced in all<br />

lighting conditions<br />

Recently introduced<br />

Ex d MODELS<br />

To obtain more information<br />

about any of the products<br />

shown in this <strong>summary</strong>, please<br />

visit our web site at<br />

www.beka.co.uk or request a<br />

copy of our full catalogue from<br />

our sales office or any of our<br />

overseas agents.


Mounting Display Display Certification<br />

height Europe ATEX USA FM & Canada cFM International IECEx<br />

Intrinsically safe – for use in gas and dust hazardous areas<br />

BA304D Field 3 1 /2 digits 25mm Group II<br />

BA324D Field 4 1 /2 digits 20mm<br />

IS/I,II,III/1/ABCDEFG Ex ia IIC T5<br />

Category 1GD*<br />

NI/I,II,III/2/ABCDEFG DIP A21 TA 80˚C IP66*<br />

EEx ia IIC T5<br />

BA307C Panel 3 1 /2 digits 13mm<br />

BA308C Panel 3 1 /2 digits 25mm Group II<br />

IS/I/1/ABCD<br />

BA327C Panel 4 1 /2 digits 10mm Category 1G<br />

NI/I/2/ABCD<br />

BA328C Panel 4 1 /2 digits 20mm EEx ia IIC T5<br />

Ex ia IIC T5<br />

BA326C Panel 4 1 /2 digits plus fast bargraph Group II IS/I/1/ABCD Ex ia IIC T5<br />

Category 1G NI/I/2/ABCD<br />

EEx ia IIC T5 (US only)<br />

Type nL – for use in Zone 2 gas and dust hazardous areas<br />

BA304ND Field 3 1 /2 digits 25mm Group II – –<br />

BA324ND Field 4 1 /2 digits 20mm Category 3GD*<br />

*ATEX and IECEx dust certification is an option<br />

EEx nL IIC T5<br />

Flameproof<br />

USA FM and Canada CSA<br />

BR323 Field 5 digits 10mm EEx d IIC T6 Ex d/1/ABCDEFG –<br />

General purpose<br />

BA504D Field 3 1 /2 digits 25mm<br />

BA524D Field 4 1 /2 digits 20mm<br />

BA507C Panel 3 1 /2 digits 13mm<br />

BA508C Panel 3 1 /2 digits 25mm<br />

BA527C Panel 4 1 /2 digits 10mm<br />

BA528C Panel 4 1 /2 digits 20mm<br />

BA526C Panel 4 1 /2 digits plus fast bargraph<br />

Set point<br />

stations<br />

Ideal for adjusting process set points<br />

from within a safe or hazardous<br />

process area, these loop powered<br />

instruments incorporate a 3 1 /2 digit<br />

display to show the 4/20mA current<br />

in engineering units.<br />

◆ ATEX & FM intrinsically safe and<br />

general purpose models<br />

◆ Easy to read display with<br />

optional:<br />

loop powered backlight<br />

or separately powered backlight<br />

◆ IP65 front panel<br />

Indicating<br />

temperature<br />

transmitters<br />

Hazardous area<br />

Certification<br />

Europe ATEX<br />

USA FM<br />

Intrinsically safe – for use in all gas hazardous areas<br />

BA405C-IND Group II Cat 1G EEx ia IIC T5 IS/I/1/ABCD<br />

NI/I/2/ABCD<br />

General purpose<br />

BA505C-IND –<br />

4/20mA<br />

Safe area<br />

Zener barriers or<br />

galvanic isolators<br />

4/20mA<br />

circuit<br />

Effectively combining a 4/20mA loop powered temperature transmitter plus a loop<br />

powered indicator, these instruments accurately display temperature on a large easy to<br />

read display and transmit an accurate, linear 4/20mA current proportional to<br />

temperature. Designed for use in all hazardous areas, this range of indicating<br />

temperature transmitters can be conditioned on-site to operate with most types of<br />

resistance thermometer and thermocouple.<br />

◆ ATEX intrinsically safe, Type nL and general purpose models<br />

◆ Loop powered - 4/20mA output<br />

◆ Bold 20mm high easy to read display<br />

◆ Temperature display in ˚C or ˚F<br />

◆ Optional alarms and display backlighting<br />

Intrinsically safe models - for use in all gas hazardous areas<br />

BA374C Field mounting, GRP or aluminium IP66 enclosure,<br />

ATEX Group II Category 1G EEx ia IIC T5<br />

BA378C Panel mounting, IP65 front ATEX Group II Category 1G EEx ia IIC T5<br />

Type nL model - for use in Zone 2 hazardous areas<br />

BA374NC Field mounting, GRP or aluminium, IP66 enclosure, ATEX Group II Category 3G


Serial text<br />

displays<br />

NOW WITH MODBUS<br />

Low cost operator interfaces that are<br />

ideal for simple machine and process<br />

control applications in hazardous and<br />

safe areas. Field mounting instruments<br />

have a robust IP66 GRP<br />

enclosure with a separate terminal<br />

compartment; the panel mounting<br />

models have IP66 sealed fronts.<br />

◆ High contrast display with backlight,<br />

operator pushbuttons and<br />

two switch outputs<br />

◆ Selectable Modbus, <strong>BEKA</strong> or<br />

Legacy protocol<br />

◆ Displays up to four variables on<br />

one of nine standard screen<br />

formats, some with bargraphs<br />

◆ ATEX, FM, cFM & IECEx certified<br />

intrinsically safe models communicate<br />

via a <strong>BEKA</strong> BA201 galvanic<br />

isolator which has RS232<br />

and RS485 safe area ports, or<br />

equivalent isolators may be used<br />

◆ General purpose models have<br />

RS232 or RS485 ports<br />

◆ Powerful pattern matching facility<br />

enables data in proprietary<br />

ASCII strings to be displayed<br />

◆ Free <strong>BEKA</strong> ScreenWriter software<br />

simplifies design of custom<br />

screen formats<br />

◆ Robust IP66 field mounting and<br />

IP66 panel mounting models<br />

FREE simulation and<br />

ScreenWriter software<br />

Operator<br />

Certification<br />

Mounting Push buttons Outputs Communication Europe ATEX USA FM & Canada cFM International IECEx<br />

Intrinsically safe – for use in all gas and dust hazardous areas<br />

IS/I,II,III/1/<br />

BA484D Field 4 2 Via BA201. Other Group II ABCDEFG EEx ia IIC T5<br />

galvanic isolators Category 1GD* NI/I,II,III/2/ EEx iaD 20 T80*<br />

may be used EEx ia IIC T5 ABCDEF<br />

Via BA201. Other Group II IS/I/1/ABCD<br />

BA488C Panel 6 2 galvanic isolators Category 1G NI/I/2/ABCD EEx ib IIC T5<br />

may be used EEx ia IIC T5<br />

General purpose<br />

BA684D Field 4 2 RS232 or<br />

RS485<br />

BA688C Panel 6 2 RS232 or<br />

RS485<br />

*ATEX & IECEx dust certification is an option<br />

Hazardous area<br />

S1 S2 S3 S4 S5 S6 S7<br />

S1 S2 S3 S4 S5 S6 S7<br />

BA488C<br />

1200<br />

820 kg<br />

0<br />

Optional external switches<br />

6<br />

5<br />

4<br />

3<br />

2<br />

1<br />

6<br />

5<br />

4<br />

3<br />

2<br />

1<br />

Safe area<br />

Recently introduced<br />

BA201<br />

Communications isolator<br />

RS232<br />

or<br />

RS485<br />

+ 20 to 35V dc<br />

To simplify hazardous area installations, the new dedicated BA201 galvanic isolator can power and communicate with up to four<br />

BA484D and BA488C serial text displays.<br />

Mounting Location Safe area No. of text displays Europe ATEX USA FM & International<br />

communication in hazardous area Canada cFM IECEx<br />

Intrinsically safe output – for use in all gas and dust hazardous areas<br />

BA201 DIN rail Safe area RS232 & 2 with 2-wire system IS circuit Group 2 IS circuit IS circuit<br />

RS485 4 with 3-wire system [Ex ia] IIC IS/I/1/ABCDEFG [Ex ia] IIC


Fieldbus<br />

indicators<br />

& displays<br />

An extensive range of robust, bus<br />

powered, single variable fieldbus<br />

indicators and eight variable fieldbus<br />

displays featuring large easy to read<br />

displays. Includes ATEX, FM, cFM and<br />

IECEx certified intrinsically safe, Type<br />

nL and nonincendive models plus<br />

general purpose instruments.<br />

FIELDBUS INDICATORS<br />

FISCO & FNICO compliant<br />

◆ Single FOUNDATION fieldbus TM variable<br />

Hazardous area<br />

Safe area<br />

◆ 5 digit 20mm high display with 31 segment bargraph<br />

BA488CF<br />

FIELDBUS DISPLAYS<br />

◆ Up to 8 FOUNDATION fieldbus TM or Profibus PA variables<br />

1 2<br />

◆ Choice of 9 standard display screen formats<br />

or custom screens<br />

◆ Backlight<br />

FISCO<br />

Terminator<br />

Fieldbus<br />

FISCO<br />

Terminator<br />

FISCO<br />

Power<br />

Supply &<br />

Segment<br />

Coupler<br />

Host<br />

◆ Operator push buttons and 6 optional outputs<br />

FISCO<br />

Field<br />

Device<br />

FISCO<br />

Field<br />

Device<br />

Certification<br />

Mounting Display Operator Outputs Protocol Europe ATEX USA FM & International<br />

Push buttons Canada cFM IECEx<br />

Intrinsically safe – for use in all gas and dust hazardous areas<br />

BA414DF Field 1 variable 0 0 FF Group II IS/I,II,III/1/ Ex ia IIC T4<br />

5 digits plus Category 1GD* ABCDEFG Ex ia IIC T4 DIP<br />

bargraph EEx ia IIC T4 NI/I,II,III/2/ A21 TA 100 o C IP66*<br />

ABCDEFG<br />

BA418CF Panel 1 variable 0 0 FF Group II IS/I/1/ABCD Ex ia IIC T4<br />

5 digits plus Category 1G NI/I/2/ABCD<br />

bargraph<br />

EEx ia IIC T4<br />

BA484DF Field 8 variables 4 6 FF Group II IS/I,II,III/1 Ex ia IIC T4<br />

120x64 pixel optional or Category 1GD* ABCDEFG Ex ia IIC T4 DIP<br />

with backlight Profibus PA EEx ia IIC T4 NI/I,II,III/2/ A21 TA 125 o C IP66*<br />

ABCDEFG<br />

(US only)<br />

BA488CF Panel 8 variables 6 6 FF Group II IS/I/1/ABCD Ex ia IIC T4<br />

120x64 pixel optional or Category 1G NI/I/2/ABCD<br />

with backlight Profibus PA EEx ia IIC T4 (US only)<br />

Type nL – for use in Zone 2 gas and dust hazardous areas<br />

BA414NDF Field 1 variable 0 0 FF Group II<br />

5 digits plus Category 3GD* Ex nL IIC T4<br />

bargraph EEx nL IIC T4 DIP A22 TA 100 o C IP66*<br />

General purpose<br />

BA614DF Field 1 variable 0 0 FF<br />

5 digits plus<br />

bargraph<br />

BA618CF Panel 1 variable 0 0 FF<br />

5 digits plus<br />

bargraph<br />

BA684DF Field 8 variables 4 6 FF<br />

120x64 pixel optional or<br />

with backlight<br />

Profibus PA<br />

BA688CF Panel 8 variables 6 6 FF<br />

120x64 pixel optional or<br />

with backlight<br />

Profibus PA<br />

*ATEX & IECEx dust certification is an option


Rate<br />

totalisers<br />

An extensive range of instruments<br />

that will calculate and display rate<br />

and total flow in engineering units<br />

from almost any flowmeter with a<br />

pulse or 4/20mA output.<br />

◆ ATEX & FM Intrinsically safe, Type<br />

nL and general purpose models<br />

◆ IP66 field mounting models and<br />

panel mounting models with IP65<br />

front sealing<br />

◆ Separate rate and total displays<br />

◆ 4/20mA input loop powered<br />

instruments<br />

◆ Externally powered and battery<br />

powered instruments for pulse<br />

inputs<br />

◆ Optional alarms, backlights and<br />

re-transmitted outputs<br />

Hazardous area<br />

TAG NUMBER<br />

Safe area<br />

SCALE<br />

visit<br />

our website<br />

w w w.beka.co. u k<br />

N<br />

Zener barriers or<br />

galvanic isolators<br />

Power<br />

24V<br />

V<br />

S<br />

Certification<br />

Mounting Input Powered Europe ATEX USA FM<br />

Intrinsically safe – for use in all gas and dust hazardous areas<br />

BA334D Field Pulse Externally Group II Cat 1GD* EEx ia IIC T5 IS/I,II,III/1/ABCDEFG<br />

NI/I,II.III/2/ABCDEFG<br />

BA338C Panel Pulse Externally Group II Cat 1G EEx ia IIC T5 IS/I/1/ABCD<br />

NI/I/2/ABCD<br />

BA344D Field Pulse Internal battery Group II Cat 1GD* EEx ia IIC T5 –<br />

BA354D Field 4/20mA Loop Group II Cat 1GD* EEx ia IIC T5 –<br />

BA358C Panel 4/20mA Loop Group II Cat 1G EEx ia IIC T5 –<br />

Type nL for use in Zone 2 gas and dust hazardous areas<br />

BA334ND Field Pulse Externally Group II Cat 3GD* –<br />

BA354ND Field 4/20mA Loop Group II Cat 3GD* –<br />

General Purpose<br />

BA534D Field Pulse Externally<br />

BA538C Panel Pulse Externally<br />

BA544D Field Pulse Internal battery<br />

BA554D Field 4/20mA Loop<br />

BA558C Panel 4/20mA Loop<br />

*ATEX dust certification is an option


Easy to use flow batch controllers for dispensing liquids, solids or components.<br />

◆ ATEX Intrinsically safe and general purpose models<br />

◆ Field and panel mounting models<br />

◆ High contrast graphical display with backlight<br />

◆ Configuration menus may be displayed in English, French or German<br />

◆ All models accept pulse and 4/20mA analogue inputs<br />

◆ Three configurable outputs, plus additional three optional outputs<br />

◆ Provision for remote push-buttons<br />

Flow batch<br />

controllers<br />

Intrinsically safe models - for use in all gas and dust hazardous areas<br />

BA454D Field mounting IP66 enclosure ATEX Group II Category 1GD*<br />

BA458C Panel mounting IP66 front ATEX Group II Category 1G<br />

General purpose<br />

BA654D Field mounting IP66 enclosure<br />

BA658C Panel mounting IP66 front<br />

*ATEX dust certification is an option<br />

Counter, timer,<br />

tachometer &<br />

clock<br />

Hazardous area<br />

TAG NUMBER<br />

SCALE<br />

P E<br />

Safe area<br />

Zener barriers or<br />

galvanic isolators<br />

N<br />

A<br />

Power<br />

24V<br />

S<br />

B<br />

V<br />

Certification<br />

Mounting Europe ATEX USA FM<br />

Intrinsically safe – for use in all gas and dust hazardous areas<br />

BA364D Field Group II Cat 1GD* IS/I,II,III/1/ABCDEFG<br />

NI/I,II.III/2/ABCDEFG<br />

BA368C Panel Group II Cat 1G IS/I/1/ABCD<br />

NI/I/2/ABCD<br />

Type nL for use in Zone 2 gas and dust hazardous areas<br />

BA364ND Field Group II Cat 3GD* –<br />

*ATEX dust certification is an option<br />

IS battery powered clock<br />

Intrinsically safe battery powered clock for use in all gas hazardous areas,<br />

featuring a high contrast 25mm display which is easy to read in most lighting<br />

conditions.<br />

◆ Intrinsically safe ATEX certified ◆ Date display<br />

◆ Three year battery life<br />

◆ Selectable automatic correction for<br />

daylight saving<br />

◆ ±1 minute accuracy per year<br />

◆ Can be synchronised to master<br />

◆ 12 or 24 hour display<br />

◆ IP66 front panel<br />

Intrinsically safe model - for use in all gas hazardous areas<br />

BA369 Panel mounting ATEX Group II Category 1G EEx ia IIC T5<br />

A unique collection of ATEX and FM certified instruments which may be conditioned<br />

on-site to perform a wide variety of counting and timing functions. In addition to pulse<br />

counting and time interval measurement or control, the instruments can display<br />

rotational speed and position from quadrature signals or be conditioned to display local<br />

time with alarm outputs.<br />

◆ ATEX & FM intrinsically safe and<br />

Type nL models<br />

◆ Two separate displays<br />

◆ Dual inputs enable instruments to<br />

decode quadrature signals and<br />

to display speed and position<br />

◆ Robust field mounting models in IP66<br />

GRP enclosure with separate terminal<br />

compartment<br />

◆ Panel mounting model with IP65<br />

front<br />

◆ Optional backlight, pulse and<br />

4/20mA outputs


EExd sounders<br />

& beacons<br />

Intrinsically safe<br />

sounder & beacon<br />

Sounder<br />

◆ 32 different sounds<br />

◆ Up to 113dB(A) output<br />

◆ PFEER compliant<br />

◆ IP67 enclosure<br />

Beacon<br />

◆ 5 joule output<br />

◆ Red, amber, yellow, green,<br />

blue or clear lens<br />

◆ IP67 enclosure<br />

Flameproof - ATEX Group II Category 2GD<br />

BExS110D sounder EEx d IIC T4*<br />

BExBG05D beacon<br />

EEx d IIC T6<br />

BExCS110-05D* Combined sounder & beacon<br />

EEx d IIB T4<br />

*ATEX dust certification is an option<br />

LED cluster lamps<br />

High performance intrinsically safe sounder and flashing beacon which<br />

may be used separately or as a pair powered from a single intrinsically<br />

safe circuit.<br />

BR385 Sounder<br />

◆ 49 different sounds<br />

◆ 3 stage alarm<br />

◆ Up to 103dB(A) output<br />

◆ PFEER compliant<br />

◆<br />

◆<br />

IP66 enclosure<br />

Will operate alone or with<br />

BA386 beacon<br />

BA386 Beacon<br />

◆ Red, amber, green, blue &<br />

white models<br />

◆ Two double flashes per<br />

second<br />

◆ Operates alone or with<br />

sounder<br />

◆ Alarm accept function<br />

silences sounder for preset<br />

time.<br />

◆ IP56 enclosure<br />

Intrinsically safe sounders for use in all gas hazardous areas<br />

BR385 ATEX Group II Cat 1G EEx ia IIC T4<br />

FM IS/I/1/ABCD<br />

Intrinsically safe beacon for use in all gas hazardous areas<br />

BA386 ATEX Group II Cat 1G EEx ia IIC T4<br />

FM IS/I/1/ABCD & NI/I/2/ABCD<br />

Panel meters<br />

BA390S operates<br />

at only 4mA<br />

Bright low cost panel mounting lamps with 10 year life<br />

expectancy<br />

◆ ATEX, IECEx & FM intrinsically safe and general purpose<br />

models<br />

◆ Red, Amber, Green, Blue & White versions<br />

◆ BA390 has constant 20mA consumption<br />

◆ BA390S has specified performance at 4mA<br />

Intrinsically safe models<br />

for use in all gas hazardous areas<br />

BA390 20mA ATEX Group II Cat 1G EEx ia IIC T4<br />

BA390S 4mA FM IS/I/1/ABCD NI/I/2/ABCD<br />

IECEx Ga Ex ia IIC T4<br />

<strong>BEKA</strong> associates Ltd<br />

High quality, cost effective general purpose panel meters<br />

featuring high brightness LED displays. Housed in robust metal<br />

enclosures with easy to clean IP65 front panels, models are<br />

available for most process inputs including resistance<br />

thermometers and thermocouples. The single range version can<br />

be supplied conditioned for measuring almost any process<br />

current or voltage.<br />

24Vdc, 115V and 230Vac powered models<br />

General Purpose<br />

A70 Single range process meter<br />

A75 Universal process meter<br />

A80 RTD input temperature meter<br />

A85 THC input temperature meter<br />

Old Charlton Road, Hitchin, Hertfordshire SG5 2DA, England www.beka.co.uk<br />

Telephone +44 (0)1462 438301 Fax +44 (0) 1462 453971 e-mail sales@beka.co.uk<br />

Printed in EU 03-09

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!