i<br />

special execution<br />

enclosures<br />

CYG<br />

• the cables are branched off by using the CYG 06H coupling in the 1 or 2 branch-off versions<br />

• multipole inserts “44.27” size can be fitted inside the two side recesses; the entire unit can be used<br />

with one lever hoods complete with connector inserts<br />

• the front faces can be fitted with “44.27” and/or “57.27” size flush bulkhead housings<br />

• CHC 06 LG cover may be used to close the coupling side faces.<br />

drawing ILME description packaging<br />

part No.<br />

NEW<br />

1 branch-off T-Box<br />

CYG 06H06 for 2 hoods with lever and gasket “44.27” size 5<br />

and one CHI housing “44.27” size<br />

CYG 06H10 for 2 hoods with lever and gasket “44.27” size 5<br />

and one CHI housing “57.27” size<br />

NEW<br />

1 branch-off T-BOX to be fitted on DIN rails<br />

CYG 06H06D for 2 hoods with lever and gasket “44.27” size 5<br />

and one CHI housing “44.27” size<br />

CYG 06H10D for 2 hoods with lever and gasket “44.27” size 5<br />

and one CHI housing “57.27” size<br />

NEW<br />

2 branch-off T-BOX<br />

CYG 06H0610 for 2 “44.27” size hoods with lever and gasket 5<br />

and 1 “44.27” size fixing side CHI housing and one “57.27” size CHI enclosure<br />

CYG 06H1006 for 2 “44.27” size hoods with lever and gasket 5<br />

and 1 “57.27” size fixing side CHI housing and one “44.27” size CHI enclosure<br />

CYG 06H0606 for 2 “44.27” size hoods with lever and gasket 5<br />

and two “44.27” and size CHI housing<br />

CYG 06H1010 for 2 “44.27”“44.27” size hoods with lever and gasket 5<br />

and two “57.27” and size CHI housing<br />

1 BRANCH-OFF T-BOX COUPLING 2 BRANCH-OFF T-BOX COUPLING<br />

C - TYPE<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

part No. <br />

CHI** CHI** CHV .. LG *<br />

CYG 06H0610 06 10 06<br />

CYG 06H1006 10 06 06<br />

CYG 06H0606 06 06 06<br />

CYG 06H1010 10 10 06<br />

the following enclosures may also be used:<br />

*MHV / CAV / MAV / CFV / MFV 06 LG<br />

**CVI / JCVI<br />

For technical data-sheet and further information please look at our technical catalogues on website www.ilme.com<br />