28.04.2015 Views

download - Ilme

download - Ilme

download - Ilme

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

i<br />

inserts<br />

for multipole<br />

connectors<br />

CSE - CSS<br />

• Double-size enclosures 77.62 and 104.62 accept two complementary inserts (16+16 or 24+24);<br />

order the standard insert and corresponding N insert for making the total polarity 32 or 48 poles.<br />

• inserts in UL recognized thermoplastic insulating self-extinguishing material<br />

• certifications: - UL - 600V ~ - with file Nr. E 115072<br />

- CSA - 600V ~ - with file Nr. LR 82270<br />

• silver plated contacts<br />

drawing ILME description packaging<br />

part No.<br />

CSE inserts - 16A - 500V<br />

spring connection section 0,14÷2,5 mm 2 - AWG 26÷14<br />

EN 61984 (2001-11): - 16A 500V 6kV 3<br />

<br />

<br />

<br />

<br />

C - TYPE INSERTS<br />

female inserts<br />

CSEF 06 06 poles + m for enclosure size 44.27 60<br />

CSEF 10 10 poles + m for enclosure size 57.27 30<br />

CSEF 16 16 poles + m for enclosure size 77.27 (and 77.62 CLASS) 30<br />

CSEF 24 24 poles + m for enclosure size 104.27 (and 104.62 JEI or CLASS) 30<br />

CSEF 16 N 16 poles + m - numbering 17 ÷ 32 for enclosure size 77.62 CLASS 30<br />

CSEF 24 N 24 poles + m - numbering 25 ÷ 48 for enclosure size 104.62 JEI or CLASS 30<br />

male inserts<br />

CSEM 06 06 poles + m for enclosure size 44.27 60<br />

CSEM 10 10 poles + m for enclosure size 57.27 30<br />

CSEM 16 16 poles + m for enclosure size 77.27 (and 77.62 CLASS) 30<br />

CSEM 24 24 poles + m for enclosure size 104.27 (and 104.62 JEI or CLASS) 30<br />

CSEM 16 N 16 poles + m - numbering 17 ÷ 32 for enclosure size 77.62 CLASS 30<br />

CSEM 24 N 24 poles + m - numbering 25 ÷ 48 for enclosure size 104.62 JEI or CLASS 30<br />

CSS inserts - 16A - 500V<br />

(double spring terminal, to be used in bulkhead housings or high construction hoods only)<br />

spring connection section 0,14÷2,5 mm 2 - AWG 26÷14<br />

EN 61984 (2001-11): - 16A 500V 6kV 3<br />

<br />

<br />

<br />

<br />

NEW<br />

female inserts<br />

CSSF 06 06 poles + m for enclosure size 44.27 10<br />

CSSF 10 10 poles + m for enclosure size 57.27 5<br />

CSSF 16 16 poles + m for enclosure size 77.27 (and 77.62 CLASS) 5<br />

CSSF 24 24 poles + m for enclosure size 104.27 (and 104.62 JEI or CLASS) 5<br />

CSSF 16 N 16 poles + m - numbering 17 ÷ 32 for enclosure size 77.62 CLASS 5<br />

CSSF 24 N 24 poles + m - numbering 25 ÷ 48 for enclosure size 104.62 JEI or CLASS 5<br />

male inserts<br />

CSSM 06 06 poles + m for enclosure size 44.27 10<br />

CSSM 10 10 poles + m for enclosure size 57.27 5<br />

CSSM 16 16 poles + m for enclosure size 77.27 (and 77.62 CLASS) 5<br />

CSSM 24 24 poles + m for enclosure size 104.27 (and 104.62 JEI or CLASS) 5<br />

CSSM 16 N 16 poles + m - numbering 17 ÷ 32 for enclosure size 77.62 CLASS 5<br />

CSSM 24 N 24 poles + m - numbering 25 ÷ 48 for enclosure size 104.62 JEI or CLASS 5<br />

Double spring terminal<br />

CSS<br />