inserts for multipole connectors<br />
JCNE - JCSE<br />
• Double-size enclosures 77.62 and 104.62 accept two complementary inserts<br />
(16+16 or 24+24); order the standard insert and corresponding N insert for making the<br />
total polarity 32 or 48 poles.<br />
• inserts in UL recognized thermoplastic insulating self-extinguishing material<br />
• certifications: - UL - 600V ~ - with file Nr. E 115072<br />
- CSA - 600V ~ - with file Nr. LR 82270<br />
• contact surface: tin plated<br />
drawing ILME description packaging<br />
part No.<br />
JCNE inserts - 16A max - 500V - screw terminal<br />
screw terminal for cable, section 0,5÷2,5 mm 2 - AWG 20÷14, with wire protection for conductors<br />
JEI INSERTS<br />
female inserts<br />
JCNEF 06 06 poles + m for enclosure size 44.27 100<br />
JCNEF 10 10 poles + m for enclosure size 57.27 80<br />
JCNEF 16 16 poles + m for enclosure size 77.27 (and 77.62 CLASS) 80<br />
JCNEF 24 24 poles + m for enclosure size 104.27 (and 104.62 JEI or CLASS) 80<br />
JCNEF 16 N 16 poles + m - numbering 17 ÷ 32 for enclosure size 77.62 CLASS 80<br />
JCNEF 24 N 24 poles + m - numbering 25 ÷ 48 for enclosure size 104.62 JEI or CLASS 80<br />
male inserts<br />
JCNEM 06 06 poles + m for enclosure size 44.27 100<br />
JCNEM 10 10 poles + m for enclosure size 57.27 80<br />
JCNEM 16 16 poles + m for enclosure size 77.27 (and 77.62 CLASS) 80<br />
JCNEM 24 24 poles + m for enclosure size 104.27 (and 104.62 JEI or CLASS) 80<br />
JCNEM 16 N 16 poles + m - numbering 17 ÷ 32 for enclosure size 77.62 CLASS 80<br />
JCNEM 24 N 24 poles + m - numbering 25 ÷ 48 for enclosure size 104.62 JEI or CLASS 80<br />
JCSE inserts - 16A max - 500V - spring connection<br />
spring connection, section 0,14÷2,5 mm 2 - AWG 26÷14<br />
<br />
<br />
<br />
<br />
female inserts<br />
JCSEF 06 06 poles + m for enclosure size 44.27 100<br />
JCSEF 10 10 poles + m for enclosure size 57.27 80<br />
JCSEF 16 16 poles + m for enclosure size 77.27 (and 77.62 CLASS) 80<br />
JCSEF 24 24 poles + m for enclosure size 104.27 (and 104.62 JEI or CLASS) 80<br />
JCSEF 16 N 16 poles + m - numbering 17 ÷ 32 for enclosure size 77.62 CLASS 80<br />
JCSEF 24 N 24 poles + m - numbering 25 ÷ 48 for enclosure size 104.62 JEI or CLASS 80<br />
male inserts<br />
JCSEM 06 06 poles + m for enclosure size 44.27 100<br />
JCSEM 10 10 poles + m for enclosure size 57.27 80<br />
JCSEM 16 16 poles + m for enclosure size 77.27 (and 77.62 CLASS) 80<br />
JCSEM 24 24 poles + m for enclosure size 104.27 (and 104.62 JEI or CLASS) 80<br />
JCSEM 16 N 16 poles + m - numbering 17 ÷ 32 for enclosure size 77.62 CLASS 80<br />
JCSEM 24 N 24 poles + m - numbering 25 ÷ 48 for enclosure size 104.62 JEI or CLASS 80<br />
C-TYPE<br />
from page 78 V-TYPE IP67 with stainless steel levers T-TYPE insulating page 64<br />
page 71<br />
JEI with zinc-plated<br />
steel levers<br />
page 67<br />
SPECIAL ENCLOSURES<br />
IP68, central<br />
lever, EMC, and<br />
aggressive<br />
environments<br />
page 113<br />
For technical data-sheet and further information please look at our technical catalogues on website www.ilme.com<br />
19