PRINCIPLES OF OPERATION<br />

REV.B<br />

2.2 ATRPS POWER SUPPLY UNIT<br />

ATRPS Unit is available in both 115-volt supply and 230-volt supply.<br />

Switch S1 selects either 115-volt supply or 230-v01t supply, and<br />

simultaneously switches a fuse.<br />

Basic Operation<br />

ATRPS Unit uses the Forward Converter Switching Regulation way.<br />

+<br />

1__Ff'<br />

MOS<br />

FET<br />

FIGURE 2-2-1.<br />

BASIC OPERATION CIRCUIT<br />

2.2.1 Primary Oscillation Circuit<br />

The HA16654 controls the MOS-FET. By supplying power to the HA16654, current<br />

flows in the liOS-FET.<br />

2.2.1.1 Power supply circuit<br />

Power supply circuit for the HA16654 is explained by the following 2 steps:<br />

1. From power on till the transformer for switching oscillates correctly.<br />

2. After the transformer for switching has oscillated correctly.<br />

1. From POWER ON till the transformer for switching oscillates correctly.<br />

The power supply circuit is shown in Figure 2-2-2.<br />

Zenor Diode D10 and Dll works so as not to supply the HA16654 with a voltage<br />

until the input voltage V reaches the fixed-level voltage.<br />