System/<br />

application<br />

Measured value display<br />

4<br />

4-wire<br />

3-phase<br />

asymmetric<br />

load<br />

L1<br />

L2<br />

L3<br />

N<br />

L1<br />

L2<br />

L3<br />

L1<br />

L2<br />

L3<br />

N<br />

u<br />

x<br />

u<br />

x<br />

u<br />

x<br />

X X X<br />

U U U<br />

Abbreviations and symbols<br />

N<br />

Terminals<br />

2 5 8 11 1 3 4 6 7 9<br />

2 5 8 11 1 3 4 6 7 9<br />

Maximum<br />

Sign<br />

k l<br />

K L<br />

k l<br />

K L<br />

Minimum<br />

Left LED<br />

group<br />

k l<br />

K L<br />

k l<br />

K L<br />

k l<br />

K L<br />

2 5 8 11 1 3 4 6 7 9<br />

k l<br />

K L<br />

3 single-pole insulated voltage transformers<br />

in high-voltage system<br />

7-segment<br />

top<br />

oL Overload, out of range indicator<br />

U.nE Neutral point voltage shift (U neutral-earth)<br />

unb.U Voltage asymmetry factor (unbalance U)<br />

in Neutral current<br />

SYSt. System power<br />

x.xx i ϕ Power factor incoming inductive<br />

x.xx c ϕ Power factor incoming capacitive<br />

- x.xx i ϕ Power factor outgoing inductive<br />

- x.xx c ϕ Power factor outgoing capacitive<br />

inc Incoming<br />

out Outgoing<br />

P<br />

7-segment<br />

centre<br />

Display Clear<br />

System/<br />

application<br />

4-wire<br />

3-phase<br />

asymmetric<br />

load,<br />

Open-Y<br />

7-segment<br />

bottom<br />

k: Kilo<br />

M: Mega<br />

M+k: Giga<br />

2 3<br />

Bottom LED group<br />

L1<br />

L2<br />

L3<br />

N<br />

L1<br />

L2<br />

L3<br />

N<br />

2 8 11 1 3 4 6 7 9<br />

u u<br />

x x<br />

X X<br />

U U<br />

cos-Phi<br />

Average value<br />

Sum or system<br />

value<br />

k<br />

Right LED<br />

group<br />

Bimetal symbol (I-avg)<br />

Delta voltage<br />

Integration symbol<br />

(interval average value)<br />

Phase 3<br />

Phase 2<br />

Phase 1<br />

k l<br />

K L<br />

l<br />

Terminals<br />

k l<br />

K L<br />

Low-voltage system<br />

K L L<br />

k<br />

K L<br />

l<br />

k l<br />

K L<br />

1 2 3 4 5 6 7 8 9 11<br />

k<br />

K L<br />

2 single-pole insulated voltage transformers<br />

in high-voltage system<br />

ind Inductive<br />

CAP Capacitive<br />

.H Energy high tariff<br />

.L Energy low tariff<br />

thd.U THD-U<br />

thd.i THD-I<br />

trnd Interval power: Trend<br />

t-0…t-4 Interval power: last to fi fth last interval<br />

H2.U…H15.U 2 nd - 15 th harmonic U<br />

H2.i…H15.i 2 nd - 15 th harmonic I<br />