10.06.2015 Views

EJX5x0A Direct-Mount Static Pressure Transmitter

EJX5x0A Direct-Mount Static Pressure Transmitter

EJX5x0A Direct-Mount Static Pressure Transmitter

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

3<br />

Minimum <strong>Pressure</strong> Limit<br />

See graph below<br />

100(750)<br />

600<br />

10(75)<br />

External<br />

load<br />

resistance<br />

R=<br />

E-10.5<br />

0.0244<br />

Digital<br />

Communication<br />

range<br />

BRAIN and HART<br />

Working<br />

2.7(20)<br />

pressure<br />

kPa abs 1(7.5)<br />

(mmHg abs)<br />

Applicable range<br />

R ()<br />

250<br />

0.13(1)<br />

0.1(0.75)<br />

0.013(0.1)<br />

0.01(0.075)<br />

-40<br />

(-40)<br />

0<br />

(32)<br />

40<br />

(104)<br />

80<br />

(176)<br />

Process temperature C(F)<br />

120 (248)<br />

85<br />

(185)<br />

F01E.EPS<br />

Figure 1-1. Working <strong>Pressure</strong> and Process Temperature<br />

[For EJX510A]<br />

100(14.5)<br />

Working<br />

pressure<br />

kPa abs<br />

(psia)<br />

10(1.4)<br />

2.7(0.38)<br />

1(0.14)<br />

-40<br />

(-40)<br />

Applicable range<br />

0<br />

(32)<br />

40<br />

(104)<br />

80<br />

(176)<br />

Process temperature C (F)<br />

Atmospheric<br />

pressure<br />

120<br />

(248)<br />

F02E.EPS<br />

Figure 1-2. Working <strong>Pressure</strong> and Process Temperature<br />

[For EJX530A]<br />

10.5 16.6 25.2 42<br />

Power supply voltage E (V DC)<br />

Figure 2. Relationship Between Power Supply Voltage<br />

and External Load Resistance<br />

F03E.EPS<br />

Supply Voltage “”<br />

10.5 to 42 V DC for general use and flameproof type.<br />

10.5 to 32 V DC for lightning protector (option code A).<br />

10.5 to 30 V DC for intrinsically safe, type n, nonincendive<br />

or non-sparking type.<br />

Minimum voltage limited at 16.6 V DC for digital<br />

communications, BRAIN and HART<br />

Load (Output signal code D and E)<br />

0 to 1290 for operation<br />

250 to 600 for digital communication<br />

Communication Requirements “”<br />

(Approval codes may affect electrical requirements.)<br />

BRAIN<br />

Communication Distance<br />

Up to 2 km (1.25 miles) when using CEV polyethylene-insulated<br />

PVC-sheathed cables. Communication<br />

distance varies depending on type of cable used.<br />

Load Capacitance<br />

0.22 F or less<br />

Load Inductance<br />

3.3 mH or less<br />

Input Impedance of communicating device<br />

10 k or more at 2.4 kHz.<br />

Supply & Load Requirements<br />

(Output signal code D and E. Optional features<br />

or approval codes may affect electrical requirements.)<br />

With 24 V DC supply, up to a 550 load can be<br />

used. See graph below.<br />

All Rights Reserved. Copyright © 2004, Yokogawa Electric Corporation<br />

GS 01C25F01-01E Aug. 31, 2005-00

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!