Outdoor Telephone Cables,Indoor Telephone Cables,Indoor/Outdoor Telephone Cables,Special Telephone Cables,CW 1171,CW 1326,CW 1326/1179,IEC 60708,DIN VDE 0816,GR-421,ICEA S-85-625,ICEA S-84-608,CW 1224,CW 1236,CW 1128,CW 1128/1179,PE-89,PE-7,CW 1166, CW 208, CW 1247,CW 1320A,CW 1406, CW 1411, CW 1417 ,CW 1378,IEC 60189-1,CW 1109, CW 1257,CW 1423,CW 1293,CW 1308,CW 1600,DIN VDE 0815,DIN VDE 0815/DIN 57815,Category 3 UTP/FTP Cables,ADSL Connecting Cables,XDSL Connecting Cables,ISDN Primary Access Air Core Cables,PE Insulated ISDN Basic Access Air Core Cables

Outdoor Telephone Cables,Indoor Telephone Cables,Indoor/Outdoor Telephone Cables,Special Telephone Cables,CW 1171,CW 1326,CW 1326/1179,IEC 60708,DIN VDE 0816,GR-421,ICEA S-85-625,ICEA S-84-608,CW 1224,CW 1236,CW 1128,CW 1128/1179,PE-89,PE-7,CW 1166, CW 208, CW 1247,CW 1320A,CW 1406, CW 1411, CW 1417 ,CW 1378,IEC 60189-1,CW 1109, CW 1257,CW 1423,CW 1293,CW 1308,CW 1600,DIN VDE 0815,DIN VDE 0815/DIN 57815,Category 3 UTP/FTP Cables,ADSL Connecting Cables,XDSL Connecting Cables,ISDN Primary Access Air Core Cables,PE Insulated ISDN Basic Access Air Core Cables

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Caledonian<br />

INDOOR TELEPHONE CABLES<br />

www.<strong>caledonian</strong>-<strong>cable</strong>s.co.uk<br />

www.addison-<strong>cable</strong>s.com<br />

(Continued from previous page)<br />

Minimum Insulation Thickness mm 0.15 0.15 0.55<br />

Maximum Insulated Conductor Diameter mm 0.85 0.95 3.5<br />

MECHANICAL AND THERMAL PROPERTIES<br />

Temperature range during operation (fixed state): -30°C – +70°C<br />

Temperature range during installation (mobile state): -20°C – +50°C<br />

Minimum bending radius: 7.5 x Overall Diameter<br />

COLOUR CODE<br />

Make Up & Unit Identification Colours – 16 Pair Unit<br />

Pair Size<br />

Centre<br />

1 st Layer<br />

2 nd Layer<br />

Unit No.<br />

8 Pairs 16 Pairs 32 Pairs 64 Pairs 128 Pairs 256 Pairs<br />

Number of Units<br />

½ 1 4 X ½ 1 4 X ½ 1<br />

Colours of Unit Lappings<br />

6 X ½ 6 5<br />

1 ORANGE ORANGE ORANGE ORANGE ORANGE ORANGE<br />

2 GREEN ORANGE GREEN ORANGE<br />

3 NATURAL ORANGE NATURAL<br />

4 GREEN NATURAL NATURAL<br />

5 NATURAL NATURAL<br />

6 NATURAL GREEN<br />

7 NATURAL ORANGE<br />

7 GREEN NATURAL<br />

9-15 NATURAL<br />

16 GREEN<br />

Note: ½ refers to sub-units of 8 Pairs.<br />

10<br />

Make Up & Unit Identification Colours – 20 Pair Unit<br />

Pair Size<br />

Centre<br />

1 st Layer<br />

2 nd Layer<br />

Unit No.<br />

10 Pairs 20 Pairs 40 Pairs 50 Pairs 80 Pairs 100 Pairs 160 Pairs 320 Pairs<br />

Number of Units<br />

½ 1 4 X ½ 5 X ½ 1 1 4 X ½ 1<br />

Colours of Unit Lappings<br />

6 X ½ 8 X ½ 6 5<br />

** 10<br />

1 ORANGE ORANGE ORANGE ORANGE ORANGE ORANGE ORANGE ORANGE<br />

2 GREEN NATURAL ORANGE ORANGE GREEN ORANGE<br />

3 GREEN* NATURAL NATURAL ORANGE NATURAL<br />

4 GREEN NATURAL NATURAL NATURAL<br />

5 GREEN NATURAL NATURAL<br />

6 NATURAL GREEN<br />

7 NATURAL ORANGE<br />

7 GREEN NATURAL<br />

9-15 NATURAL<br />

16 GREEN<br />

Note 1: ½ refers to sub-units of 10 Pairs.<br />

Note 2: These <strong>cable</strong>s include the single 1.38mm diameter insulated conductor.<br />

* The Green colour lapping shall be applied to the last ½ unit.<br />