Outdoor Telephone Cables,Indoor Telephone Cables,Indoor/Outdoor Telephone Cables,Special Telephone Cables,CW 1171,CW 1326,CW 1326/1179,IEC 60708,DIN VDE 0816,GR-421,ICEA S-85-625,ICEA S-84-608,CW 1224,CW 1236,CW 1128,CW 1128/1179,PE-89,PE-7,CW 1166, CW 208, CW 1247,CW 1320A,CW 1406, CW 1411, CW 1417 ,CW 1378,IEC 60189-1,CW 1109, CW 1257,CW 1423,CW 1293,CW 1308,CW 1600,DIN VDE 0815,DIN VDE 0815/DIN 57815,Category 3 UTP/FTP Cables,ADSL Connecting Cables,XDSL Connecting Cables,ISDN Primary Access Air Core Cables,PE Insulated ISDN Basic Access Air Core Cables

Outdoor Telephone Cables,Indoor Telephone Cables,Indoor/Outdoor Telephone Cables,Special Telephone Cables,CW 1171,CW 1326,CW 1326/1179,IEC 60708,DIN VDE 0816,GR-421,ICEA S-85-625,ICEA S-84-608,CW 1224,CW 1236,CW 1128,CW 1128/1179,PE-89,PE-7,CW 1166, CW 208, CW 1247,CW 1320A,CW 1406, CW 1411, CW 1417 ,CW 1378,IEC 60189-1,CW 1109, CW 1257,CW 1423,CW 1293,CW 1308,CW 1600,DIN VDE 0815,DIN VDE 0815/DIN 57815,Category 3 UTP/FTP Cables,ADSL Connecting Cables,XDSL Connecting Cables,ISDN Primary Access Air Core Cables,PE Insulated ISDN Basic Access Air Core Cables

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

ADDISON<br />

ELECTRICAL PROPERTIES<br />

Nominal Conductor Diameter mm 0.6 0.8 0.6 0.8<br />

VDE CODE J-Y(St)Y J-Y(St)Y J-H(St)H J-H(St)H<br />

Conductor Size mm 2 0.283 0.5 0.283 0.5<br />

Maximum Conductor Resistance @20°C Ω/km 63 34.6 63 34.6<br />

Maximum Loop Resistance @20°C Ω/km 130 73.2 130 73.2<br />

Minimum Insulation Resistance @500V DC @20°C MΩ . km 100 100 100 100<br />

Maximum Average Attenuation @0.8KHz dB/km 1.7 1.1 1.7 1.1<br />

Maximum Mutual Capacitance @0.8KHz* nF/km 100 100 120 120<br />

Maximum Capacitance Unbalance K1 pF/100m 300 300 300 300<br />

Maximum Working Voltage Peak Value V 300 300 300 300<br />

Insulation Material PVC PVC LSZH LSZH<br />

Sheath Material PVC PVC LSZH LSZH<br />

Nominal Insulation Thickness mm 0.3 0.4 0.3 0.4<br />

Nominal Insulated Conductor Diameter mm 1.2 1.6 1.2 1.6<br />

* In Cables up to 4 pairs 120nF/km<br />

MECHANICAL AND THERMAL PROPERTIES<br />

Temperature range during operation (fixed state): -30°C – +70°C<br />

Temperature range during installation (mobile state): -20°C – +50°C<br />

Minimum bending radius: 7.5 x Overall Diameter<br />

COLOUR CODE<br />

In 2 pair- <strong>cable</strong>s:<br />

Pair 1: a-wire red b-wire black<br />

Pair 2: a-wire white b-wire yellow<br />

In <strong>cable</strong>s with 4 and more pairs:<br />

a-wire of the 1st pair in each layer red, in all other pairs white<br />

b-wire blue, yellow, green, brown, black in repeated sequence counting direction from the outside to the inside.<br />

DIMENSIONS AND WEIGHT<br />

VDE CODE: J-Y(St)Y …x2x0.6/0.8 Lg<br />

Cable Code<br />

Number of<br />

Pairs<br />

Nominal Insulation<br />

Thickness<br />

mm<br />

Nominal Sheath<br />

Thickness<br />

mm<br />

Nominal Overall<br />

Diameter<br />

mm<br />

0.6mm Conductor, 1.2mm Insulated Wire<br />

T815J-Y(St)Y-Lg-1P06 1 0.3 1.0 4.8 30<br />

T815J-Y(St)Y-Lg-2P06 2 0.3 1.0 5.0 40<br />

T815J-Y(St)Y-Lg-3P06 3 0.3 1.0 6.3 50<br />

T815J-Y(St)Y-Lg-4P06 4 0.3 1.0 6.5 60<br />

T815J-Y(St)Y-Lg-5P06 5 0.3 1.0 7.2 70<br />

T815J-Y(St)Y-Lg-6P06 6 0.3 1.0 7.5 80<br />

T815J-Y(St)Y-Lg-8P06 8 0.3 1.0 8.0 90<br />

T815J-Y(St)Y-Lg-10P06 10 0.3 1.0 10.0 110<br />

T815J-Y(St)Y-Lg-12P06 12 0.3 1.0 10.2 130<br />

T815J-Y(St)Y-Lg-14P06 14 0.3 1.0 10.5 145<br />

T815J-Y(St)Y-Lg-16P06 16 0.3 1.0 11.0 160<br />

T815J-Y(St)Y-Lg-20P06 20 0.3 1.0 12.0 190<br />

Nominal<br />

Weight<br />

kg/km<br />

112 Caledonian Telephone Cables www.addison-<strong>cable</strong>s.com www.<strong>caledonian</strong>-<strong>cable</strong>s.co.uk