02.07.2015 Views

caledonian telephone cable

Outdoor Telephone Cables,Indoor Telephone Cables,Indoor/Outdoor Telephone Cables,Special Telephone Cables,CW 1171,CW 1326,CW 1326/1179,IEC 60708,DIN VDE 0816,GR-421,ICEA S-85-625,ICEA S-84-608,CW 1224,CW 1236,CW 1128,CW 1128/1179,PE-89,PE-7,CW 1166, CW 208, CW 1247,CW 1320A,CW 1406, CW 1411, CW 1417 ,CW 1378,IEC 60189-1,CW 1109, CW 1257,CW 1423,CW 1293,CW 1308,CW 1600,DIN VDE 0815,DIN VDE 0815/DIN 57815,Category 3 UTP/FTP Cables,ADSL Connecting Cables,XDSL Connecting Cables,ISDN Primary Access Air Core Cables,PE Insulated ISDN Basic Access Air Core Cables

Outdoor Telephone Cables,Indoor Telephone Cables,Indoor/Outdoor Telephone Cables,Special Telephone Cables,CW 1171,CW 1326,CW 1326/1179,IEC 60708,DIN VDE 0816,GR-421,ICEA S-85-625,ICEA S-84-608,CW 1224,CW 1236,CW 1128,CW 1128/1179,PE-89,PE-7,CW 1166, CW 208, CW 1247,CW 1320A,CW 1406, CW 1411, CW 1417 ,CW 1378,IEC 60189-1,CW 1109, CW 1257,CW 1423,CW 1293,CW 1308,CW 1600,DIN VDE 0815,DIN VDE 0815/DIN 57815,Category 3 UTP/FTP Cables,ADSL Connecting Cables,XDSL Connecting Cables,ISDN Primary Access Air Core Cables,PE Insulated ISDN Basic Access Air Core Cables

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Caledonian<br />

INDOOR TELEPHONE CABLES<br />

www.<strong>caledonian</strong>-<strong>cable</strong>s.co.uk<br />

www.addison-<strong>cable</strong>s.com<br />

PE/PVC Insulated Parallel Drop Wires to RUS (REA) PE-7<br />

APPLICATION<br />

The drop wires are designed for use in extending <strong>telephone</strong> circuits to subscriber premises by<br />

means of an aerial drop from distribution wire or <strong>cable</strong>s. The shape may be in oval/dumbbell<br />

shape to aid in separation of conductors.<br />

STANDARDS<br />

• RUS (REA) PE-7<br />

• ASTM B227, B452 & B1<br />

CONSTRUCTION<br />

• Conductors: Two conductors made of 0.9/1.0/1.023mm copper covered steel wires serve dually as conductor and<br />

strength members.<br />

• Bonding: Bonding of the insulation to the conductors is made to assure the full conductor strength is transferred to the<br />

wire support clamps.<br />

• Insulation: Conductors are laid in a parallel configuration and covered with low density or medium density polyethylene<br />

(PE) or polyvinyl chloride (PVC).<br />

ELECTRICAL PROPERTIES<br />

Nominal Conductor Diameter mm 0.9 1.0 1.023<br />

Conductor Gauge Size AWG 19 18.5 18<br />

Conductor Size mm 2 0.636 0.785 0.827<br />

Minimum Insulation Resistance @500V DC MΩ . km / MΩ . kft 30/100 30/100 30/100<br />

Dielectric Strength Conductor to Conductor(3secs) V DC 7050 7050 7050<br />

Nominal Insulation Thickness mm/inch 1.02/0.039 1.02/0.039 1.02/0.039<br />

Nominal Insulated Conductor Diameter mm/inch 2.94/0.116 3.04/0.117 3.06/0.118<br />

MECHANICAL AND THERMAL PROPERTIES<br />

Temperature range during operation (fixed state): -30°C – +70°C<br />

Temperature range during installation (mobile state): -20°C – +50°C<br />

Minimum bending radius: 7.5 x Overall Diameter<br />

DIMENSIONS AND WEIGHT<br />

Cable Code<br />

Number of Insulation Nominal Insulation Thickness Nominal Overall Dimensions Nominal Weight<br />

Cores Material<br />

mm/inch<br />

mm/inch<br />

kg/km / lbs/kft<br />

1.023mm Conductor, 3.06 Insulated Wire<br />

TP7-2Y-1P18A-SS 2 PE 1.02/0.04 3.0x7.0/0.11x0.28 32/22<br />

TP7-Y-1P18A-SS 2 PVC 1.45/0.06 3.9x7.6/0.15x0.30 49/33<br />

1.0mm Conductor, 3.04 Insulated Wire<br />

TP7-Y-1P18/5A-SS 2 PVC 1.02/0.04 3.9x7.4/0.15x0.29 46/31<br />

0.9mm Conductor, 2.94 Insulated Wire<br />

TP7-2Y-1P19A-SS 2 PE 1.02/0.04 2.9x7.7/0.11x0.30 25/17<br />

ADDISON<br />

089

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!