Outdoor Telephone Cables,Indoor Telephone Cables,Indoor/Outdoor Telephone Cables,Special Telephone Cables,CW 1171,CW 1326,CW 1326/1179,IEC 60708,DIN VDE 0816,GR-421,ICEA S-85-625,ICEA S-84-608,CW 1224,CW 1236,CW 1128,CW 1128/1179,PE-89,PE-7,CW 1166, CW 208, CW 1247,CW 1320A,CW 1406, CW 1411, CW 1417 ,CW 1378,IEC 60189-1,CW 1109, CW 1257,CW 1423,CW 1293,CW 1308,CW 1600,DIN VDE 0815,DIN VDE 0815/DIN 57815,Category 3 UTP/FTP Cables,ADSL Connecting Cables,XDSL Connecting Cables,ISDN Primary Access Air Core Cables,PE Insulated ISDN Basic Access Air Core Cables

Outdoor Telephone Cables,Indoor Telephone Cables,Indoor/Outdoor Telephone Cables,Special Telephone Cables,CW 1171,CW 1326,CW 1326/1179,IEC 60708,DIN VDE 0816,GR-421,ICEA S-85-625,ICEA S-84-608,CW 1224,CW 1236,CW 1128,CW 1128/1179,PE-89,PE-7,CW 1166, CW 208, CW 1247,CW 1320A,CW 1406, CW 1411, CW 1417 ,CW 1378,IEC 60189-1,CW 1109, CW 1257,CW 1423,CW 1293,CW 1308,CW 1600,DIN VDE 0815,DIN VDE 0815/DIN 57815,Category 3 UTP/FTP Cables,ADSL Connecting Cables,XDSL Connecting Cables,ISDN Primary Access Air Core Cables,PE Insulated ISDN Basic Access Air Core Cables

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

ADDISON<br />

MICA/LSZH Insulated & LSZH Sheathed Fire Resistant Cables to<br />

DIN VDE 0815<br />

JE-H(St)H…Bd FE180 E90<br />

JE-H(St)H…Bd FE180 E90 BMK<br />

APPLICATION<br />

The <strong>cable</strong>s are similar in design and application to CW 1600, but with fire barrier<br />

tape. They are used for the internal wiring of building when the circuit integrity during<br />

fire is paramount. The <strong>cable</strong> is intended to take the place of LSZH sheathed <strong>cable</strong>s<br />

and will withstand similar environments with a similar working life. The <strong>cable</strong>s are<br />

intended for use in fire fighting plants with mica tapes, with and without aluminium foil<br />

and LSZH outer sheath.<br />

STANDARDS<br />

• EN 50200:2000-02 • EN 50266 • EN 50267<br />

• EN 50268 • BS 6387 • IEC 60331<br />

CONSTRUCTION<br />

• Conductors: Solid annealed bare or tinned copper sized 0.8mm as per class 1 of VDE 0295/IEC 60228.<br />

• Fire Barrier: Mica tape.<br />

• Insulation: LSZH compound HI1 as per VDE 0207-23.<br />

• Twisted Pairs: Insulated conductors are twisted into pairs with varying lay length to minimize crosstalk.<br />

• Cabling Element: Twisted Pairs.<br />

• Core Assembly: The twisted pairs are stranded to the core in layers.<br />

• Core Wrapping: One or more non hygroscopic polyester tapes are helically or longitudinally laid with an overlap prior to<br />

sheathing.<br />

• Screen: A laminated Aluminium/Polyester tape in contact with solid copper 0.6mm or 0.8mm drain wire.<br />

• Inner bedding (for armoured <strong>cable</strong>s): PE or LSZH compound HM2 as per VDE 0207-24<br />

• Armour (for armoured <strong>cable</strong>s): Either corrugated steel tape armour or galvanized steel wire is applied over an inner<br />

polyethylene sheath. For steel tape armour, the 0.15mm thick steel tape is coated with a copolymer and applied with an<br />

overlap. For steel wire armour, single layer of galvanized steel wire armour is applied.<br />

• Sheath: LSZH compound HM2 as per VDE 0207-24.<br />

• Ripcord: Nylon ripcord may be placed parallel to the cores to facilitate sheath removal.<br />

• Drain Wire: A solid tinned earth/continuity wire shall be laid longitudinally for screened <strong>cable</strong>s.<br />

TYPE CODES<br />

JE-<br />

H<br />

Fire Alarm Cable<br />

Halogen Free & Zero Halogen<br />

122 Caledonian Telephone Cables www.addison-<strong>cable</strong>s.com www.<strong>caledonian</strong>-<strong>cable</strong>s.co.uk