caledonian telephone cable
Outdoor Telephone Cables,Indoor Telephone Cables,Indoor/Outdoor Telephone Cables,Special Telephone Cables,CW 1171,CW 1326,CW 1326/1179,IEC 60708,DIN VDE 0816,GR-421,ICEA S-85-625,ICEA S-84-608,CW 1224,CW 1236,CW 1128,CW 1128/1179,PE-89,PE-7,CW 1166, CW 208, CW 1247,CW 1320A,CW 1406, CW 1411, CW 1417 ,CW 1378,IEC 60189-1,CW 1109, CW 1257,CW 1423,CW 1293,CW 1308,CW 1600,DIN VDE 0815,DIN VDE 0815/DIN 57815,Category 3 UTP/FTP Cables,ADSL Connecting Cables,XDSL Connecting Cables,ISDN Primary Access Air Core Cables,PE Insulated ISDN Basic Access Air Core Cables
Outdoor Telephone Cables,Indoor Telephone Cables,Indoor/Outdoor Telephone Cables,Special Telephone Cables,CW 1171,CW 1326,CW 1326/1179,IEC 60708,DIN VDE 0816,GR-421,ICEA S-85-625,ICEA S-84-608,CW 1224,CW 1236,CW 1128,CW 1128/1179,PE-89,PE-7,CW 1166, CW 208, CW 1247,CW 1320A,CW 1406, CW 1411, CW 1417 ,CW 1378,IEC 60189-1,CW 1109, CW 1257,CW 1423,CW 1293,CW 1308,CW 1600,DIN VDE 0815,DIN VDE 0815/DIN 57815,Category 3 UTP/FTP Cables,ADSL Connecting Cables,XDSL Connecting Cables,ISDN Primary Access Air Core Cables,PE Insulated ISDN Basic Access Air Core Cables
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Caledonian<br />
OUTDOOR TELEPHONE CABLES<br />
www.<strong>caledonian</strong>-<strong>cable</strong>s.co.uk<br />
www.addison-<strong>cable</strong>s.com<br />
(Continued from previous page)<br />
@6.3MHz dB/305m / dB/kft 34 34 34 34<br />
Minimum Near-end Cross-talk-Worst Pair Power Sum<br />
@150KHz dB/305m / dB/kft 53 53 53 53<br />
@772KHz dB/305m / dB/kft 42 42 42 42<br />
@1.6MHz dB/305m / dB/kft 38 38 38 38<br />
@3.15MHz dB/305m / dB/kft 33 33 33 33<br />
@6.3MHz dB/305m / dB/kft 29 29 29 29<br />
Nominal Insulation Thickness mm 0.15 0.2 0.26 0.3<br />
Nominal Insulated Conductor Diameter mm 0.7 0.9 1.15 1.5<br />
MECHANICAL AND THERMAL PROPERTIES<br />
Temperature range during operation (fixed state): -30°C – +70°C<br />
Temperature range during installation (mobile state): -20°C – +50°C<br />
Minimum bending radius: 10 x Overall Diameter (unarmoured <strong>cable</strong>s);15 x Overall Diameter (armoured <strong>cable</strong>s)<br />
COLOUR CODE<br />
Standard colour code is per ICEA S-85-625 given in Colour Code Chart<br />
DIMENSIONS AND WEIGHT<br />
Solid PE Insulated and LAP Sheathed Air Core Cable to ICEA S-85-625 (formerly RUS (REA) PE-22)<br />
Cable Code<br />
Number of Pairs<br />
Nominal Sheath<br />
Thickness<br />
mm/inch<br />
Nominal Overall<br />
Diameter<br />
mm/inch<br />
Nominal Weight<br />
kg/km / lbs/kft<br />
0.4mm Conductor, 0.7mm Insulated Wire<br />
TP22-2Y(L)2Y-3P04 3 1.5/0.059 8.0/0.32 55/37<br />
TP22-2Y(L)2Y-5P04 5 1.5/0.059 8.5/0.33 60/40<br />
TP22-2Y(L)2Y-6P04 6 1.5/0.059 9.0/0.35 65/44<br />
TP22-2Y(L)2Y-10P04 10 1.5/0.059 9.5/0.37 80/54<br />
TP22-2Y(L)2Y-12P04 12 1.5/0.059 10.0/0.39 90/60<br />
TP22-2Y(L)2Y-15P04 15 1.5/0.059 10.5/0.41 100/67<br />
TP22-2Y(L)2Y-20P04 20 1.5/0.059 11.0/0.43 120/81<br />
TP22-2Y(L)2Y-25P04 25 1.5/0.059 12.0/0.47 140/94<br />
TP22-2Y(L)2Y-30P04 30 1.5/0.059 12.5/0.49 155/104<br />
TP22-2Y(L)2Y-40P04 40 1.5/0.059 13.5/0.53 190/128<br />
TP22-2Y(L)2Y-50P04 50 1.5/0.059 14.5/0.57 220/148<br />
TP22-2Y(L)2Y-75P04 75 1.5/0.059 16.5/0.65 300/202<br />
TP22-2Y(L)2Y-100P04 100 1.5/0.059 18.0/0.71 380/255<br />
TP22-2Y(L)2Y-150P04 150 1.5/0.059 21.0/0.83 540/363<br />
TP22-2Y(L)2Y-200P04 200 1.5/0.059 24.0/0.94 690/464<br />
TP22-2Y(L)2Y-300P04 300 1.5/0.059 30.5/1.20 1000/672<br />
TP22-2Y(L)2Y-400P04 400 1.8/0.071 31.5/1.24 1300/874<br />
TP22-2Y(L)2Y-600P04 600 2.0/0.079 37.5/1.48 1900/1277<br />
ADDISON<br />
035