02.07.2015 Views

caledonian telephone cable

Outdoor Telephone Cables,Indoor Telephone Cables,Indoor/Outdoor Telephone Cables,Special Telephone Cables,CW 1171,CW 1326,CW 1326/1179,IEC 60708,DIN VDE 0816,GR-421,ICEA S-85-625,ICEA S-84-608,CW 1224,CW 1236,CW 1128,CW 1128/1179,PE-89,PE-7,CW 1166, CW 208, CW 1247,CW 1320A,CW 1406, CW 1411, CW 1417 ,CW 1378,IEC 60189-1,CW 1109, CW 1257,CW 1423,CW 1293,CW 1308,CW 1600,DIN VDE 0815,DIN VDE 0815/DIN 57815,Category 3 UTP/FTP Cables,ADSL Connecting Cables,XDSL Connecting Cables,ISDN Primary Access Air Core Cables,PE Insulated ISDN Basic Access Air Core Cables

Outdoor Telephone Cables,Indoor Telephone Cables,Indoor/Outdoor Telephone Cables,Special Telephone Cables,CW 1171,CW 1326,CW 1326/1179,IEC 60708,DIN VDE 0816,GR-421,ICEA S-85-625,ICEA S-84-608,CW 1224,CW 1236,CW 1128,CW 1128/1179,PE-89,PE-7,CW 1166, CW 208, CW 1247,CW 1320A,CW 1406, CW 1411, CW 1417 ,CW 1378,IEC 60189-1,CW 1109, CW 1257,CW 1423,CW 1293,CW 1308,CW 1600,DIN VDE 0815,DIN VDE 0815/DIN 57815,Category 3 UTP/FTP Cables,ADSL Connecting Cables,XDSL Connecting Cables,ISDN Primary Access Air Core Cables,PE Insulated ISDN Basic Access Air Core Cables

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Caledonian<br />

OUTDOOR TELEPHONE CABLES<br />

www.<strong>caledonian</strong>-<strong>cable</strong>s.co.uk<br />

www.addison-<strong>cable</strong>s.com<br />

(Continued from previous page)<br />

@6.3MHz dB/305m / dB/kft 34 34 34 34<br />

Minimum Near-end Cross-talk-Worst Pair Power Sum<br />

@150KHz dB/305m / dB/kft 53 53 53 53<br />

@772KHz dB/305m / dB/kft 42 42 42 42<br />

@1.6MHz dB/305m / dB/kft 38 38 38 38<br />

@3.15MHz dB/305m / dB/kft 33 33 33 33<br />

@6.3MHz dB/305m / dB/kft 29 29 29 29<br />

Nominal Insulation Thickness mm 0.15 0.2 0.26 0.3<br />

Nominal Insulated Conductor Diameter mm 0.7 0.9 1.15 1.5<br />

MECHANICAL AND THERMAL PROPERTIES<br />

Temperature range during operation (fixed state): -30°C – +70°C<br />

Temperature range during installation (mobile state): -20°C – +50°C<br />

Minimum bending radius: 10 x Overall Diameter (unarmoured <strong>cable</strong>s);15 x Overall Diameter (armoured <strong>cable</strong>s)<br />

COLOUR CODE<br />

Standard colour code is per ICEA S-85-625 given in Colour Code Chart<br />

DIMENSIONS AND WEIGHT<br />

Solid PE Insulated and LAP Sheathed Air Core Cable to ICEA S-85-625 (formerly RUS (REA) PE-22)<br />

Cable Code<br />

Number of Pairs<br />

Nominal Sheath<br />

Thickness<br />

mm/inch<br />

Nominal Overall<br />

Diameter<br />

mm/inch<br />

Nominal Weight<br />

kg/km / lbs/kft<br />

0.4mm Conductor, 0.7mm Insulated Wire<br />

TP22-2Y(L)2Y-3P04 3 1.5/0.059 8.0/0.32 55/37<br />

TP22-2Y(L)2Y-5P04 5 1.5/0.059 8.5/0.33 60/40<br />

TP22-2Y(L)2Y-6P04 6 1.5/0.059 9.0/0.35 65/44<br />

TP22-2Y(L)2Y-10P04 10 1.5/0.059 9.5/0.37 80/54<br />

TP22-2Y(L)2Y-12P04 12 1.5/0.059 10.0/0.39 90/60<br />

TP22-2Y(L)2Y-15P04 15 1.5/0.059 10.5/0.41 100/67<br />

TP22-2Y(L)2Y-20P04 20 1.5/0.059 11.0/0.43 120/81<br />

TP22-2Y(L)2Y-25P04 25 1.5/0.059 12.0/0.47 140/94<br />

TP22-2Y(L)2Y-30P04 30 1.5/0.059 12.5/0.49 155/104<br />

TP22-2Y(L)2Y-40P04 40 1.5/0.059 13.5/0.53 190/128<br />

TP22-2Y(L)2Y-50P04 50 1.5/0.059 14.5/0.57 220/148<br />

TP22-2Y(L)2Y-75P04 75 1.5/0.059 16.5/0.65 300/202<br />

TP22-2Y(L)2Y-100P04 100 1.5/0.059 18.0/0.71 380/255<br />

TP22-2Y(L)2Y-150P04 150 1.5/0.059 21.0/0.83 540/363<br />

TP22-2Y(L)2Y-200P04 200 1.5/0.059 24.0/0.94 690/464<br />

TP22-2Y(L)2Y-300P04 300 1.5/0.059 30.5/1.20 1000/672<br />

TP22-2Y(L)2Y-400P04 400 1.8/0.071 31.5/1.24 1300/874<br />

TP22-2Y(L)2Y-600P04 600 2.0/0.079 37.5/1.48 1900/1277<br />

ADDISON<br />

035

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!