caledonian telephone cable
Outdoor Telephone Cables,Indoor Telephone Cables,Indoor/Outdoor Telephone Cables,Special Telephone Cables,CW 1171,CW 1326,CW 1326/1179,IEC 60708,DIN VDE 0816,GR-421,ICEA S-85-625,ICEA S-84-608,CW 1224,CW 1236,CW 1128,CW 1128/1179,PE-89,PE-7,CW 1166, CW 208, CW 1247,CW 1320A,CW 1406, CW 1411, CW 1417 ,CW 1378,IEC 60189-1,CW 1109, CW 1257,CW 1423,CW 1293,CW 1308,CW 1600,DIN VDE 0815,DIN VDE 0815/DIN 57815,Category 3 UTP/FTP Cables,ADSL Connecting Cables,XDSL Connecting Cables,ISDN Primary Access Air Core Cables,PE Insulated ISDN Basic Access Air Core Cables
Outdoor Telephone Cables,Indoor Telephone Cables,Indoor/Outdoor Telephone Cables,Special Telephone Cables,CW 1171,CW 1326,CW 1326/1179,IEC 60708,DIN VDE 0816,GR-421,ICEA S-85-625,ICEA S-84-608,CW 1224,CW 1236,CW 1128,CW 1128/1179,PE-89,PE-7,CW 1166, CW 208, CW 1247,CW 1320A,CW 1406, CW 1411, CW 1417 ,CW 1378,IEC 60189-1,CW 1109, CW 1257,CW 1423,CW 1293,CW 1308,CW 1600,DIN VDE 0815,DIN VDE 0815/DIN 57815,Category 3 UTP/FTP Cables,ADSL Connecting Cables,XDSL Connecting Cables,ISDN Primary Access Air Core Cables,PE Insulated ISDN Basic Access Air Core Cables
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Caledonian<br />
INDOOR TELEPHONE CABLES<br />
www.<strong>caledonian</strong>-<strong>cable</strong>s.co.uk<br />
www.addison-<strong>cable</strong>s.com<br />
PVC/LSZH Insulated & PVC/LSZH Sheathed Switchboard Cables<br />
to DIN VDE 0815<br />
J-Y(St)Y…2X0.6 Lg<br />
J-H(St)H…2X0.6 Lg<br />
J-Y(St)Y…2X0.8 Lg<br />
J-H(St)H…2X0.8 Lg<br />
APPLICATION<br />
The installation <strong>cable</strong>s are used for <strong>telephone</strong> and signal transmission and suitable<br />
for permanent installation on and under plaster in dry and damp rooms and for<br />
permanent installation on external walls. They are designed to handle low frequency<br />
analogue or digital signals for flexible installation.<br />
STANDARDS<br />
• DIN VDE 0815<br />
CONSTRUCTION<br />
• Conductors: Solid annealed bare copper sized 0.6/0.8mm as per VDE 0295/IEC 60228 Class 1.<br />
• Insulation: PVC YI1 type to DIN VDE 0207-4. LSZH compound can be offered as option.<br />
• Twisted Pairs: Insulated conductors are twisted into pairs with varying lay length to minimize crosstalk.<br />
• Cabling Element: Twisted Pairs.<br />
• Cable Core Assembly: The twisted pairs are stranded to <strong>cable</strong> core in layers.<br />
• Core Wrapping: One or more non-hygroscopic polyester tapes are helically or longitudinally laid with an overlap prior to<br />
sheathing.<br />
• Screen: Laminated aluminium foil is provided for fully enclosing the core with an overlap.<br />
• Sheath: PVC YM1 type to DIN VDE 0207-5. LSZH sheath can be offered as option.<br />
• Ripcord: Nylon ripcord may be placed parallel to the cores to facilitate sheath removal.<br />
• Drain Wire: Drain wire with a diameter of 0.4mm is provided in <strong>cable</strong>s up to 10 pairs. Drain wire with a diameter of 0.6mm<br />
is provided in <strong>cable</strong>s with more than 10 pairs.<br />
TYPE CODES<br />
J- Installation Cable<br />
Y Polyvinylchloride (PVC)<br />
H Low Smoke & Zero Halogen<br />
(St) Static Shield<br />
Lg Stranded in layers<br />
ADDISON<br />
111