caledonian telephone cable

Outdoor Telephone Cables,Indoor Telephone Cables,Indoor/Outdoor Telephone Cables,Special Telephone Cables,CW 1171,CW 1326,CW 1326/1179,IEC 60708,DIN VDE 0816,GR-421,ICEA S-85-625,ICEA S-84-608,CW 1224,CW 1236,CW 1128,CW 1128/1179,PE-89,PE-7,CW 1166, CW 208, CW 1247,CW 1320A,CW 1406, CW 1411, CW 1417 ,CW 1378,IEC 60189-1,CW 1109, CW 1257,CW 1423,CW 1293,CW 1308,CW 1600,DIN VDE 0815,DIN VDE 0815/DIN 57815,Category 3 UTP/FTP Cables,ADSL Connecting Cables,XDSL Connecting Cables,ISDN Primary Access Air Core Cables,PE Insulated ISDN Basic Access Air Core Cables

Outdoor Telephone Cables,Indoor Telephone Cables,Indoor/Outdoor Telephone Cables,Special Telephone Cables,CW 1171,CW 1326,CW 1326/1179,IEC 60708,DIN VDE 0816,GR-421,ICEA S-85-625,ICEA S-84-608,CW 1224,CW 1236,CW 1128,CW 1128/1179,PE-89,PE-7,CW 1166, CW 208, CW 1247,CW 1320A,CW 1406, CW 1411, CW 1417 ,CW 1378,IEC 60189-1,CW 1109, CW 1257,CW 1423,CW 1293,CW 1308,CW 1600,DIN VDE 0815,DIN VDE 0815/DIN 57815,Category 3 UTP/FTP Cables,ADSL Connecting Cables,XDSL Connecting Cables,ISDN Primary Access Air Core Cables,PE Insulated ISDN Basic Access Air Core Cables

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Caledonian<br />

INDOOR TELEPHONE CABLES<br />

www.<strong>caledonian</strong>-<strong>cable</strong>s.co.uk<br />

www.addison-<strong>cable</strong>s.com<br />

PVC/LSZH Insulated & PVC/LSZH Sheathed Switchboard Cables<br />

to DIN VDE 0815<br />

J-Y(St)Y…2X0.6 Lg<br />

J-H(St)H…2X0.6 Lg<br />

J-Y(St)Y…2X0.8 Lg<br />

J-H(St)H…2X0.8 Lg<br />

APPLICATION<br />

The installation <strong>cable</strong>s are used for <strong>telephone</strong> and signal transmission and suitable<br />

for permanent installation on and under plaster in dry and damp rooms and for<br />

permanent installation on external walls. They are designed to handle low frequency<br />

analogue or digital signals for flexible installation.<br />

STANDARDS<br />

• DIN VDE 0815<br />

CONSTRUCTION<br />

• Conductors: Solid annealed bare copper sized 0.6/0.8mm as per VDE 0295/IEC 60228 Class 1.<br />

• Insulation: PVC YI1 type to DIN VDE 0207-4. LSZH compound can be offered as option.<br />

• Twisted Pairs: Insulated conductors are twisted into pairs with varying lay length to minimize crosstalk.<br />

• Cabling Element: Twisted Pairs.<br />

• Cable Core Assembly: The twisted pairs are stranded to <strong>cable</strong> core in layers.<br />

• Core Wrapping: One or more non-hygroscopic polyester tapes are helically or longitudinally laid with an overlap prior to<br />

sheathing.<br />

• Screen: Laminated aluminium foil is provided for fully enclosing the core with an overlap.<br />

• Sheath: PVC YM1 type to DIN VDE 0207-5. LSZH sheath can be offered as option.<br />

• Ripcord: Nylon ripcord may be placed parallel to the cores to facilitate sheath removal.<br />

• Drain Wire: Drain wire with a diameter of 0.4mm is provided in <strong>cable</strong>s up to 10 pairs. Drain wire with a diameter of 0.6mm<br />

is provided in <strong>cable</strong>s with more than 10 pairs.<br />

TYPE CODES<br />

J- Installation Cable<br />

Y Polyvinylchloride (PVC)<br />

H Low Smoke & Zero Halogen<br />

(St) Static Shield<br />

Lg Stranded in layers<br />

ADDISON<br />