Outdoor Telephone Cables,Indoor Telephone Cables,Indoor/Outdoor Telephone Cables,Special Telephone Cables,CW 1171,CW 1326,CW 1326/1179,IEC 60708,DIN VDE 0816,GR-421,ICEA S-85-625,ICEA S-84-608,CW 1224,CW 1236,CW 1128,CW 1128/1179,PE-89,PE-7,CW 1166, CW 208, CW 1247,CW 1320A,CW 1406, CW 1411, CW 1417 ,CW 1378,IEC 60189-1,CW 1109, CW 1257,CW 1423,CW 1293,CW 1308,CW 1600,DIN VDE 0815,DIN VDE 0815/DIN 57815,Category 3 UTP/FTP Cables,ADSL Connecting Cables,XDSL Connecting Cables,ISDN Primary Access Air Core Cables,PE Insulated ISDN Basic Access Air Core Cables

Outdoor Telephone Cables,Indoor Telephone Cables,Indoor/Outdoor Telephone Cables,Special Telephone Cables,CW 1171,CW 1326,CW 1326/1179,IEC 60708,DIN VDE 0816,GR-421,ICEA S-85-625,ICEA S-84-608,CW 1224,CW 1236,CW 1128,CW 1128/1179,PE-89,PE-7,CW 1166, CW 208, CW 1247,CW 1320A,CW 1406, CW 1411, CW 1417 ,CW 1378,IEC 60189-1,CW 1109, CW 1257,CW 1423,CW 1293,CW 1308,CW 1600,DIN VDE 0815,DIN VDE 0815/DIN 57815,Category 3 UTP/FTP Cables,ADSL Connecting Cables,XDSL Connecting Cables,ISDN Primary Access Air Core Cables,PE Insulated ISDN Basic Access Air Core Cables

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

ADDISON<br />

PVC Insulated Jumper Wires to IEC 60189-1<br />

APPLICATION<br />

The jumper wires are used for interconnection between terminal blocks at main<br />

distribution frames (MDF), cross connection cabinets (CCP) and distribution frames or<br />

boxes.<br />

STANDARDS<br />

• IEC 60189-1<br />

• IEC 60332-1<br />

• UL1581 Sec.VW-1<br />

CONSTRUCTION<br />

• Conductors: Solid annealed tinned copper 0.5/0.6/0.8mm as per IEC 60228 Class 1.<br />

• Insulation: PVC<br />

• Twisted Pairs: Insulated conductors are twisted into pairs with varying lays to minimize crosstalk.<br />

ELECTRICAL PROPERTIES<br />

Nominal Conductor Diameter mm 0.5 0.6 0.8<br />

Conductor Size mm 2 0.196 0.283 0.5<br />

Maximum Conductor Resistance @20°C Ω/km 98 66 35<br />

Minimum Insulation Resistance @500V DC MΩ . km 50 50 50<br />

Nominal Insulation Thickness mm 0.225 0.225 0.275<br />

Nominal Insulated Conductor Diameter mm 0.95 1.05 1.35<br />

MECHANICAL AND THERMAL PROPERTIES<br />

Temperature range during operation (fixed state): -30°C – +70°C<br />

Temperature range during installation (mobile state): -20°C – +50°C<br />

Minimum bending radius: 7.5 x Overall Diameter<br />

COLOUR CODE<br />

Standard colour code is per IEC 60189-1.<br />

094 Caledonian Telephone Cables www.addison-<strong>cable</strong>s.com www.<strong>caledonian</strong>-<strong>cable</strong>s.co.uk